background image

 

 

1 of 13 

© 2010 GE Security, Inc. 

P/N 1069667 • REV 1.0 • ISS 22FEB10 

GE 

Security 

GE-DSG-244 DSSG-244 and 

244-PoE Managed Ethernet 

Switch Installation Sheet 

Package Contents 

Thank you for purchasing the GE Security GE-DSG/DSSG series of 24-Port 
Managed Ethernet Switches. The following Switch model numbers are covered in 
this sheet: 

 GE-DSG-244 

• GE-DSSG-244 

• GE-DSSG-244-PoE

 

 

Open the box of the Managed Switch and carefully unpack it. The box should 
contain the following items: 

•  The GE-DSG/DSSG Managed Gigabit Switch x1 
•  User's manual CD x1 
•  Installation Sheet x1 
•  RS232 cable x1 
•  Rubber feet x 4 
•  Two rack-mounting brackets with attachment screws x2 
• Power 

Cord 

x1 

•  CB-STX50-50cm stack cable x 1 (GE-DSSG Series only)  

If any item is found missing or damaged, please contact your local reseller for 
replacement. 

Summary of Contents for GE-DSG-244

Page 1: ...bers are covered in this sheet GE DSG 244 GE DSSG 244 GE DSSG 244 PoE Open the box of the Managed Switch and carefully unpack it The box should contain the following items The GE DSG DSSG Managed Gigabit Switch x1 User s manual CD x1 Installation Sheet x1 RS232 cable x1 Rubber feet x 4 Two rack mounting brackets with attachment screws x2 Power Cord x1 CB STX50 50cm stack cable x 1 GE DSSG Series o...

Page 2: ...ard Serial Port connection Terminal Above PC with COM Port DB 9 Ethernet Port connection Network cables Use standard network UTP cables with RJ45 connectors Above PC installed with WEB Browser and JAVA runtime environment Plug in Note We recommend using Windows XP or Windows 7 with Internet Explorer 6 0 or above for access to the switch management setup Terminal Setup Three are ways to access and ...

Page 3: ...witch Windows Hyper Terminal program is a good choice The Hyper Terminal program can be accessed from the Start menu 1 Click START then Programs Accessories and then Hyper Terminal 2 When the following screen appears make sure that the COM port should be configured as Baud 115200 Parity None Data bits 8 Stop bits 1 Flow Control None Figure 2 COM1 properties window ...

Page 4: ...login screen is Password admin Figure 3 Managed Switch Console Login screen Note For security reasons please change and memorize the new password after this first setup Passwords must be entered in lowercase letters in the console interface Configure IP address The GE DSG GE DSSG Managed Switch is shipped with default IP address as follows IP Address 192 168 0 100 Subnet Mask 255 255 255 0 To chec...

Page 5: ...sk and Gateway As show in Figure 4 Figure 4 IP information Screen Configure IP address 1 On Switch prompt enter the following command and press Enter As show in Figure 5 Switch ip setup 192 168 1 100 255 255 255 0 192 168 1 1 The previous command would apply the follow settings for the Switch IP 192 168 1 100 Subnet Mask 255 255 255 0 Gateway 192 168 1 1 ...

Page 6: ... the IP is successfully configured the Managed Switch will apply the new IP address setting immediately You can access the Web interface of GE DSG GE DSSG Managed Switch through the new IP address Note If you are not familiar with console command or the related parameter enter anytime in console to get the help description ...

Page 7: ...erminal program is required to make the software connection to the Managed Switch Windows Hyper Terminal program is a good choice Hyper Terminal can be accessed from the Start menu Click START then Programs Accessories and then Hyper Terminal 3 The following screen will appear Input a new connection name You should use something like the model name of your switch Figure 7 New Connection dialog win...

Page 8: ...port number is 23 then press the OK button Figure 8 The Connect to dialog window Log on to the Console Make sure the device finished booting Once telnet has connected to the device hyper terminal will display the login request Then the following message asks the login user name and password The factory default password as following and the login screen as following appear User name admin Password ...

Page 9: ...he GE DSG GE DSSG Managed Switch Please note that the Managed Switch is configured through an Ethernet connection make sure the manager PC must be set on the same IP subnet address For example the default IP address of the GE DSG GE DSSG Managed Switch is 192 168 0 100 then the manager PC should be set at 192 168 0 x where x is a number between 1 and 254 except 100 and the default subnet mask is 2...

Page 10: ...s http 192 168 0 100 the factory default IP address or that you have just changed in the console to access the Web interface 2 When the following dialog box appears please enter the default password admin or the password you have changed via console The login screen in Figure 11 appears Default IP Address 192 168 0 100 Default Password admin Figure 11 Login Screen ...

Page 11: ...E DSG 244 and for GE DSSG Series the display will be the same as GE DSG 244 Figure 12 Main Screen of the Managed Switch 4 Now you can use the Web management interface to continue the Switch management please refer to the user manual for more information Note For security reasons please change and memorize the new password after this first setup ...

Page 12: ...is located near the right top of the Web page Reset Button To reset the IP address to the default IP Address 192 168 0 100 or reset the login password to default value Press the hardware reset button at the front panel about 10 seconds After the device is rebooted you can login the management WEB interface within the same subnet of 192 168 0 xx Figure 14 Reset Button location ...

Page 13: ...ecurity support team 888 GE Security 888 437 3287 Toll free in the US Puerto Rico and Canada 503 885 5700 outside of the toll free area For contact information see our Web site www gesecurity com For contact information see our Web site www gesecurity eu Copyright GE Security Technology Corp 2009 Contents subject to revision without prior notice GE Security is a registered trademark of GE Security...

Reviews: