GE FQROMF Owner'S Manual & Installation Instructions Download Page 2

2

Notes:

(1) Tested by NSF International per NSF/ANSI

Standard 58.

(2) Tested by NSF laboratory against accepted

industry protocol.

(3) #/mL is the number of particles per milliliter.

(4) NTU is Nephelometric Turbidity Units.

(5) Efficiency rating means the percentage of the

influent water to the system that is available to

the user as reverse osmosis treated water under

operating conditions that approximate typical

daily usage.

(6) Recovery rating means the percentage of

influent water to the membrane portion of the

system that is available to the user as reverse

osmosis treated water when the system is

operated without a storage tank or when the

storage tank is bypassed.

(7) For model PNRQ20F only: This system 

is acceptable for treatment of influent

concentrations of no more than 27 mg/L

Nitrate and 3 mg/L Nitrite in combination

measured as N and is certified for Nitrate/Nitrite

reduction only for water supplies with a pressure

of 280 kPa (40 psig) or greater.

Notes :

(1) Essayé par NSF International conformément à la

norme 58 de NSF/ANSI.

(2) Essayé par le laboratoire NSF conformément au

protocole accepté par l’industrie.

(3) #/mL est le nombre de particules par millilitre. 

(4) NTU représente les unités de turbidité

néphélémétriques. 

(5) La notation d’efficacité indique l’eau entrant dans

le système qui est disponible pour l’utilisateur

comme eau traitée par osmose inversée dans des

conditions de fonctionnement qui ressemblent à

celles d’utilisation journalière normale. 

(6) La notation de recouvrement indique le

pourcentage d’eau entrant dans le système par

rapport à la portion de membrane du système qui

est disponible pour l’utilisateur comme eau traitée

par osmose inversée quand le système fonctionne

sans réservoir ou quand le réservoir est

contourné.

(7) Modèle de PNRQ20F seulement : Ce système est

acceptable pour le traitement de concentrations

entrantes inférieures à 27 mg/L de nitrates et 

3 mg/L de nitrites en combinaisons mesurées

comme N, et n’est certifié pour la réduction 

des nitrates/nitrites que pour des débits

d’alimentation d’eau ayant une pression 

de 200 kPa (40 psig) ou plus.

Notas:

(1) Probado por NSF International por el Estándar 58

NSF/ANSI.

(2) Probado por el laboratorio NSF contra el

protocolo aceptado por la industria. 

(3) #/mL es el número de partículas por milímetro.

(4) NTU es Unidades de Turbidez Nepelométricas.

(5) El Ritmo de eficiencia significa el porcentaje de

agua influente al sistema que está disponible al

usuario como agua tratada por la osmosis reversa

bajo las condiciones de operación que se

aproximan al uso típico diario.

(6) El Ritmo de recuperación significa el porcentaje

de agua influyente a la porción de membrana del

sistema que está disponible al usuario como agua

tratada por la osmosis reversa cuando el sistema se

opera sin el tanque de almacenamiento o cuando

el tanque de almacenamiento es circunvalado.

(7) Modelo de PNRQ20F solamente: Este sistema 

es aceptable para tratamiento de concentraciones

entrantes de un máximo de 27mg/L Nitrato y 

3 mg/L Nitrito en combinación medidas como 

N y está certificado para la reducción de

Nitrato/Nitrito únicamente para suministros 

de agua con una presión de 200 kPa (40 psig) 

o mayor.

Contaminants Reduced by this Model / Contaminants réduits par ce modèle / Contaminantes reducidos en este modelo

USEPA

Influent

Influent

Effluent

% Reduction

Min. Required

Parameter

MCL

Challenge Concentration

Average

Average

Maximum

Average

Minimum

Reduction

USEPA

Concentation d’amorce 

Moyenne dans 

Eau sortante

Réduction en pourcentage 

Réduction requise 

Parametre

MCL

dans l’eau entrante 

l’eau entrante 

Moyenne 

Maximum

Moyen 

Minimum

minimum

USEPA

Influente Influente

Efluente

% de reducción

Reducción mínima 

Parámetro

MCL

Concentración de reto

Promedio 

Promedio

Máximo 

Promedio

Mínimo

necesaria

Standard No. 58: Reverse Osmosis Drinking Water Treatment Systems / Norme No 58; Systèmes de traitement de l’eau potable par osmose inversée / Norma No. 58: Sistemas de tratamiento de agua potable por Ósmosis Inversa

Asbestos

(2)

/Amiante

(2)

/Amianto

(2)

99%

10

7

to 10

fibers/L;

297 µF/L

<1

<1

99.9%

99.8%

>99%

reduction/

Fibers greater than 10µm

réduction/

10

7

à 10

8

de fibres/L; 

reducción

Fibres plus grandes que 10 µm

10

7

a 10

8

fibras/ L; 

Fibras mayores a 10µm

Pentavalent Arsenic

(1)

/

0.025 mg/L

0.050 mg/L + 10%

0.051 mg/L

<0.0002 mg/L

<0.0002 mg/L

96.0%

95.5%

<0.0002 mg/L

Arsenic pentavalent

(1)

/

Arsénico pentavalente

(1)

Barium

(1)

/Baryum

(1)

/Bario

(1)

2 mg/L

10 mg/L + 10%

9.971 mg/L

0.0813 mg/L

0.290 mg/L

99.2%

97.4%

0.003 mg/L

Cadmium

(1)

/Cadmium

(1)

/Cadmio

(1)

0.005 mg/L

0.030 mg/L + 10%

0.030 mg/L

0.0005 mg/L

0.0009 mg/L

98.4%

97.1%

0.010 mg/L

Chromium (VI)

(1)

/Chrome (VI)

(1)

/

0.100 mg/L

0.300 mg/L + 10%

0.291 mg/L

0.0091 mg/L

0.020 mg/L

96.8%

92.0%

0.0002 mg/L

Cromo (VI)

(1)

Chromium (III)

(1)

/Chrome (III)

(1)

/

0.100 mg/L

0.300 mg/L + 10%

0.299 mg/L

0.0022 mg/L

0.004 mg/L

99.3%

98.8%

0.0017 mg/L

Cromo (III)

(1)

Copper

(1)

/Cuivre

(1)

/Cobre

(1)

1.3 mg/L

3.0 mg/L + 10%

2.964 mg/L

0.0345 mg/L

0.069 mg/L

98.8%

97.4%

0.003 mg/L

Cysts

(1)(3)

/Spores

(1)(3)

/Quiste

(1)(3)

99.95% > 50,000 #/mL

94,857 #/mL

11 #/mL

24 #/mL

99.99%

99.97%

>99.95%

reduction/
réduction/

reducción

Lead

(1)

/Plomb

(1)

/Plomo

(1)

0.010 mg/L

0.15 mg/L + 10%

0.149 mg/L

0.0022 mg/L

0.005 mg/L

98.5%

96.7%

0.010 mg/L

Selenium

(1)

/Sélénium

(1)

/Selenio

(1)

0.05 mg/L

0.10 mg/L + 10%

0.101 mg/L

<0.006 mg/L

<0.006 mg/L

94.1%

93.5%

0.002 mg/L

TDS

(1)

/MTD

(1)

/TDS

(1)

187 mg/L

750 mg/L + 40%

0.757 mg/L

60 mg/L

88 mg/L

92.0%

90.9%

>75.0%

Turbidity

(1)(4)

/Turbidité

(1)(4)

/

0.5 NTU***

80 + 40% NTU***

80.6 NTU

0.1178 NTU

0.21 NTU

99.8%

99.7%

0.5 NTU

Turbidez

(1)(4)

Additional Substances Reduced by this Model / Substances supplémentaires réduites par ce modèle / Sustancias adicionales reducidas por este modelo

USEPA

Influent

Influent

Effluent

% Reduction

Min. Required

Parameter

MCL

Challenge Concentration

Average

Average

Maximum

Average

Minimum

Reduction

USEPA

Concentation d’amorce 

Moyenne dans 

Eau sortante

Réduction en pourcentage 

Réduction requise 

Parametre

MCL

dans l’eau entrante 

l’eau entrante 

Moyenne 

Maximum

Moyen 

Minimum

minimum

USEPA

Influente Influente

Efluente

% de reducción

Reducción mínima 

Parámetro

MCL

Concentración de reto

Promedio 

Promedio

Máximo 

Promedio

Mínimo

necesaria

Standard No. 58: Reverse Osmosis Drinking Water Treatment Systems / Norme No 58; Systèmes de traitement de l’eau potable par osmose inversée / Norma No. 58: Sistemas de tratamiento de agua potable por Ósmosis Inversa

Bicarbonate

(2)

/

230 mg/L + 15%

229 mg/L

26 mg/L

43 mg/L

88.7%

81.3%

Bicarbonate

(2)

/

Bicarbonato

(2)

Chloride

(2)

/Chlore

(2)

/Cloruro

(2)

250 mg/L

700 mg/L + 10%

696 mg/L

195 mg/L

330 mg/L

72.0%

52.2%

Magnesium

(2)

/

30.0 mg/L + 20%

28.2 mg/L

0.19 mg/L

0.66 mg/L

99.3%

97.4%

Magnésium

(2)

/

Magnesio

(2)

Nitrate

(1)

/Nitrate

(1)

/Nitrato

(1)(7)

10 mg/L

27.0 mg/L + 10%

27.1 mg/L

4.5 mg/L

5.1 mg/L

80.9%

76.4%

10 mg/L

Nitrite

(1)

/Nitrite

(1)

/Nitrito

(1)(7)

1 mg/L

3.0 mg/L + 10%

2.9 mg/L

0.56 mg/L

0.68 mg/L

80.9%

76.4%

1.0 mg/L

Sodium

(2)

/Sodium

(2)

/Sodio

(2)

600 mg/L + 20%

586 mg/L

146 mg/L

260 mg/L

75.0%

50.9%

Sulfate

(2)

/Sulfate

(2)

/Sulfato

(2)

250 mg/L

900 mg/L + 20%

901 mg/L

17 mg/L

40 mg/L

98.2%

95.6%

Tannin

(2)

/Tanin

(2)

/Titanio

(2)

1.4 mg/L + 40%

1.4 mg/L

0.1 mg/L

0.1 mg/L

92.1%

87.5%

Zinc

(2)

/Zinc

(2)

/Zinc

(2)

5 mg/L

12.0 mg/L + 30%

12.4 mg/L

0.54 mg/L

2.60 mg/L

96.0%

81.7%

Operating Specifications / Caractéristiques de fonctionnement / Especificaciones de operación

Inlet Pressure/Pression d’entrée/Presión de entrada

40–120 psig (2.8–7.0 kg/cm

2

)

Inlet Temperature/Température d’entrée/Temperatura de entrada

40–100°F (5–38°C)

Maximum TDS Level/Niveau maximal de MTD/Nivel TDS máximo

2000 mg/L

Maximum Hardness/Dureté maximale/Dureza máxima  @6.9 pH

10 grains per gallon/10 grains par gallon/10 granos por galón (171 mg/L)

Maximum Chlorine/Chlore maximal/Cloruro máximo

2.0 mg/L

pH Range/Ph/Rango pH

4–10

Daily Production Rate–models PXRQ15F/FBL/Taux de production journalière–modèles de PXRQ15F/FBL/Ritmo diario de producción–modelos de PXRQ15F/FBL

11 gal per day/11 gal par jour/11 galones por día

Daily Production Rate–model PNRQ20F/Taux de production journalière–modèle de PNRQ20F/Ritmo diario de producción–modelo de PNRQ20F

15.5 gal per day/15.5 gal par jour/15.5 galones por día

Efficiency Rating

(6)

/Notation d’efficacité

(6)

/Ritmo de eficiencia

(5)

12.5

Recovery Rating

(7)

/Notation de recouvrement

(7)

/Ritmo de recuperación

(6)

25.5

Summary of Contents for FQROMF

Page 1: ...ANSI 58 Las pruebas NSF ANSI 58 se realizaron en condiciones normales para pruebas El desempeño real puede variar según las condiciones locales del agua No debe usarse en aquellos lugares en los que el agua no es microbiológicamente segura o si se desconoce la calidad del agua Cerciórese de que el agua se desinfecta adecuadamente ya sea a la entrada o a la salida del sistema Sistemas certificados ...

Page 2: ...r Ósmosis Inversa Asbestos 2 Amiante 2 Amianto 2 99 107 to 108 fibers L 297 µF L 1 1 99 9 99 8 99 reduction Fibers greater than 10µm réduction 107 à 108 de fibres L reducción Fibres plus grandes que 10 µm 107 a 108 fibras L Fibras mayores a 10µm Pentavalent Arsenic 1 0 025 mg L 0 050 mg L 10 0 051 mg L 0 0002 mg L 0 0002 mg L 96 0 95 5 0 0002 mg L Arsenic pentavalent 1 Arsénico pentavalente 1 Bari...

Page 3: ...modèle ne convertira pas l arsenic trivalent en arsenic pentavalent Si vous avez des résidus de monoxyde de chlore dans votre approvisionnement d eau tout votre arsenic trivalent sera converti en arsenic pentavalent et sera éliminé par votre système d osmose inversée D autres produits chimiques de traitement d eau comme l ozone et le permanganate de potassium convertiront également l arsenic triva...

Page 4: ...es Vous pouvez installer l un de ces filtres à la place de l autre Vous devez installer la cartouche d osmose inversée au centre 8 Ouvrez l approvisionnement d eau pour remplir le système cela peut prendre jusqu à quatre heures Vérifiez qu il n y a pas de fuite 9 Enlevez le tiroir à pile et remettez la pile le côté positif vers le bas pour remettre en marche la minuterie et la fonction de surveill...

Reviews: