– 15 –
Remove the wire harness from the control timer.
Remove the single ¼-in. hex-head screw.
5.
6.
Wire Harness
Lift up slightly on the tab where the screw
was located and rotate the timer clockwise (as
viewed from back) to release it from the 2 tab-
locks.
7.
Control Timer Removed From Control Panel
Tab-lock
Tab-lock
Water Level Switch
The minimum fi ll volume is 9 gallons. The water
level measures approximately 7½ inches (6
holes) above the bottom of the basket.
The maximum fi ll volume is 22 gallons. The
water level measures approximately 15 inches
above the bottom of the basket (between holes
2 and 3 from the top).
•
•
To remove the water level switch:
Disconnect power.
Remove the water level switch knob by gently
pulling it outward.
Place the control panel in the service position.
(See
Control Panel
.)
1.
2.
3.
Minimum Fill Level