GE DuraDrum GTDX200GM Installation Instructions Manual Download Page 6

Installation Instructions

6

CONNECTING THE DRYER

TO HOUSE VENT

RIGID METAL TRANSITION DUCT

• For best drying performance, a rigid metal transition duct is 

recommended.

• Rigid metal transitions ducts reduce the risk of crushing and 

kinking.

UL-LISTED FLEXIBLE METAL (SEMI-RIGID TRANSITION DUCT

• If rigid metal duct cannot be used, then UL-listed flexible metal 

(semi-rigid) ducting can be used (Kit WX08X10077).

• Never install flexible metal duct in walls, ceilings, floors or 

other enclosed spaces.

• Total length of flexible metal duct should not exceed 8 feet 

(2.4m).

• For many applications, installing elbows at both the dryer 

and the wall is highly recommended (see illustrations below). 

Elbows allow the dryer to sit close to the wall without kinking 

and or crushing the transition duct, maximizing drying 

performance.

• Avoid resting the duct on sharp objects. UL-LISTED FLEXIBLE 

METAL (FOIL-TYPE) TRANSITION DUCT

• In special installations, it may be necessary to connect the 

dryer to the house vent using a flexible metal (foiltype) duct. 

A UL-listed flexible metal (foil-type)duct may be used ONLY 

in installations where rigid metal or flexible metal (semi-rigid) 

ducting cannot be used AND where a 4” diameter can be 

maintained throughout the entire length of the transition 

duct.

• In Canada and the United States, only the flexible metal(foil-

type) ducts that comply with the “Outline for Clothes Dryer 

Transition Duct Subject 2158A” shall be used.

• Never install flexible metal duct in walls, ceilings, floors or 

other enclosed spaces.

• Total length of flexible metal duct should not exceed 8 feet 

(2.4m).

• Avoid resting the duct on sharp objects.

• For best drying performance:

1. Slide one end of the duct over the clothes dryer

outlet pipe.

2. Secure the duct with a clamp.

3. With the dryer in its permanent position, extend the

duct to its full length. Allow 2” of duct to overlap the

exhaust pipe. Cut off and remove excess duct. Keep

the duct as straight as possible for maximum airflow.

4. Secure the duct to the exhaust pipe with the other

clamp.

ELBOWS HIGHLY

RECOMMENDED

ELBOW HIGHLY

RECOMMENDED

DO

DO NOT

SIT D RYER

ON FLEXIBLE

EXHAUS T.

DO NOT USE

EXCESSIVE

EXHAUST

LENGTH

DO NOT

CRUSH

FLEXIBLE

EXHAUST

AGAINST

WALL.

DON’T

9

ALCOVE OR CLOSET INSTALLATION

• If your dryer is approved for installation in an alcove or closet, 

it will be stated on a label on the dryer back.

• The dryer MUST be vented to the outdoors. See the EXHAUST 

INFORMATION section.

• Minimum clearance between dryer cabinet and adjacent 

walls or other surfaces is:

0 in. either side

3 in. front and rear

• Minimum vertical space from floor to overhead cabinets, 

ceiling, etc. is 52 in.

• Closet doors must be louvered or otherwise ventilated and 

must contain a minimum of 60 sq. in. of open area equally 

distributed. If the closet contains both a washer and a dryer, 

doors must contain a minimum of 120 sq.in. of open area 

equally distributed.

• The closet should be vented to the outdoors to prevent gas 

pocketing in case of a gas leak in the supply line.

• No other fuel-burning appliance shall be installed in the same 

closet with the dryer.

11 MOBILE OR MANUFACTURED HOME INSTALLATION

• Installation must conform to the MANUFACTURED HOME 

CONSTRUCTION & SAFETY STANDARD, TITLE 24, PART 32-80 

or, when such standard is not applicable, with AMERICAN 

NATIONAL STANDARD FOR MOBILE HOME, NO. 501B.

• The dryer MUST be vented to the outdoors with the 

termination securely fastened to the mobile home structure. 

(See EXHAUST INFORMATION section 6.)

• The vent MUST NOT be terminated beneath a mobile or 

manufactured home.

• The vent duct material MUST BE METAL.

• KIT 14-D346-33 MUST be used to attach the dryer securely to 

the structure.

• The vent MUST NOT be connected to any other duct, vent, or 

chimney.

• Do not use sheet metal screws or other refastening devices 

which extend into the interior of the exhaust vent.

• Provide an opening with a free area of at least 25 sq. in.or 

introduction of outside air into the dryer room.

10 BATHROOM OR BEDROOM INSTALLATION

• The dryer MUST be vented to the outdoors. See EXHAUST 

INFORMATION section 6.

• The installation must conform with local codes or, in the 

absence of local codes, with the NATIONAL FUEL GAS CODE, 

ANSI Z223.

Summary of Contents for DuraDrum GTDX200GM

Page 1: ...all 1 800 GECARES US or Visit our Web site at www GEAppliances com US BEFORE YOU BEGIN Read these instructions completely and carefully IMPORTANT Save these instructions for local inspector s use IMPORTANT Observe all governing codes and ordinances Note to Installer Be sure to leave these instructions with the customer Note to Customer Keep these instructions with your Use and Care Book for future...

Page 2: ...ation of the plugged tapping Supply line is to be 1 2 in rigid pipe and equipped with an accessible shut off within 6 ft of and in the same room with the dryer Use pipe thread sealer compound or Teflon tape appropri ate for natural or LP gas You must use with this dryer a flexible metal connector listed connector ANSI Z21 24 CSA 6 10 The length of the connect shall not exceed 3 ft Connect flexible...

Page 3: ...nd thread sealant Caution Use adapters as shown Connector nuts must not be connected directly to pipe threads WARNING NEVER USE AN OPEN FLAME TO TEST FOR GAS LEAKS FLARE NPT PIPE SIZE Listed connector ANSI Z21 24 CSA 6 10 1 8 NPT PIPE PLUG FOR CHECKING GAS INLET PRESSURE AT LEAST 1 2 3 8 NPT TIGHTEN THE FLEXIBLE GAS LINE USING TWO ADJUSTABLE WRENCHES TIGHTEN ALL CONNECTIONS USING TWO ADJUSTABLE WR...

Page 4: ...t performance separate all turns by at least 4 ft of straight duct including distance between last turn and exhaust hood TURNS OTHER THAN 90º One turn of 45º or less may be ignored Two 45º turns should be treated as one 90º turn Each turn over 45º should be treated as one 90º turn SEALING OF JOINTS All joints should be tight to avoid leaks The male end of each section of duct must point away from ...

Page 5: ...int creates a potential fire hazard Do not use duct longer than specified in the exhaust length table Longer ducts can accumulate lint creating a potential fire hazard Never install a screen in or over the exhaust duct This will cause lint to accumulate creating a potential fire hazard Do not assemble ductwork with any fasteners that extend into the duct These fasteners can accumulate lint creatin...

Page 6: ...to the exhaust pipe with the other clamp ELBOWSHIGHLY RECOMMENDED ELBOWHIGHLY RECOMMENDED DO DONOT SITD RYER ONFLEXIBLE EXHAUS T DONOTUSE EXCESSIVE EXHAUST LENGTH DONOT CRUSH FLEXIBLE EXHAUST AGAINST WALL DON T 9 ALCOVE OR CLOSET INSTALLATION If your dryer is approved for installation in an alcove or closet it will be stated on a label on the dryer back The dryer MUST be vented to the outdoors See...

Page 7: ...int Insert duct assembly elbow first through the side opening and connect the elbow to the dryer internal duct CAUTION Be sure not to pull or damage the electrical wires inside the dryer when inserting the duct Apply duct tape as shown on the joint between the dryer internal duct and the elbow Cut the duct as shown and keep portion A 9 A B FIXING HOLE Through the rear opening locate the tab in the...

Page 8: ...ADDING COVER PLATE TO REAR OF CABINET Connect standard metal elbows and ducts to complete the exhaust system Cover back opening with a plate Kit WE1M454 available from your local service provider Place dryer in final location WARNING NEVER LEAVE THE BACK OPENING WITHOUT THE PLATE CAUTION Internal duct joints must be secured with tape otherwise they may separate and cause a safety hazard ROTATE DOO...

Page 9: ...and until firmly seated 4 Insert the filter screen in the coupling of the washer s inlet hose If a rubber flat washer is already in place remove it before installing the filter screen Attach this coupling to one male end of the Y connector Tighten by hand until firmly seated 5 Ensure the rubber flat washer is in place and attach the dryer s long inlet hose to the other male end of the Y connector ...