Installation Instructions
4
E
/
ECTRICA
/
CONNECTION
INFORMATION
E
/
ECTRICA
/
RE
48
IREMENTS
7KLVDSSOLDQFHPXVWEHVXSSOL]DQG
FRQQHFWHGWRDSURSHUO\JURXQGHGEUDQFKFLUFXLW
SURWHFWHGE\DRUDPSFLUFXLWEUHDNHURUWLPH
GHOD\IXVH,IHOHFWULFDOVXSSO\SURYLGHGGRHVQRWPHHWWKH
DERYHVSHFL¿FDWLRQVLWLVUHFRPPHQGHGWKDWDOLFHQVHG
HOHFWULFLDQLQVWDOODQDSSURYHGRXWOHW
WARNING
TO RED
8
CE T
+
E
RISK OF FIRE
E
/
ECTRICA
/
S
+
OCK
AND
3
ERSONA
/
IN
-8
RY:
DO NOT
8
SE AN E
;
TENSION CORD OR AN ADA
3
TER
3/8
G WIT
+
T
+
IS A
33/
IANCE
'U\HUPXVWEHHOHFWULFDOO\JURXQGHGLQDFFRUGDQFH
ZLWKORFDOFRGHVDQGRUGLQDQFHVRULQWKHDEVHQFH
RIORFDOFRGHVLQDFFRUGDQFHZLWKWKH1$7,21$/
(/(&75,&$/&2'($16,1)3$12
WARNING
THIS DRYER IS
E
48
I
33
ED A THREE
3
RONG
GRO
8
NDING
3/8
G FOR YO
8
R
3
ROTECTION AGAINST
SHOCK HA
=
ARD AND SHO
8/
D
%
E
3/8
GGED
DIRECT
/
Y INTO A
3
RO
3
ER
/
Y GRO
8
NDED
THREE
3
RONG RECE
3
TAC
/
E
DO NOT C
8
T
OR REMO
9
E THE GRO
8
NDING
3
RONG FROM
THIS
3/8
G
ENSURE PROPER GROUND
EXISTS BEFORE USE.
IF LOCAL CODES PERMIT,
AN EXTERNAL GROUND WIRE
(NOT PROVIDED), WHICH MEETS
LOCAL CODES, MAY BE ADDED
BY ATTACHING TO THE GREEN
GROUND SCREW ON THE REAR
OF THE DRYER, AND TO A GROUNDED
METAL COLD WATER PIPE OR OTHER
ESTABLISHED GROUND.
6
E
;
HA
8
ST INFORMATION
E
;
HA
8
ST SYSTEM CHECK
/
IST
HOOD OR WA
//
CA
3
7HUPLQDWHLQDPDQQHUWRSUHYHQWEDFNGUDIWVRUHQWU\RIELUGV
RURWKHUZLOGOLIH
7HUPLQDWLRQVKRXOGSUHVHQWPLQLPDOUHVLVWDQFHWRWKHH[KDXVW
DLUÀRZDQGVKRXOGUHTXLUHOLWWOHRUQRPDLQWHQDQFHWRSUHYHQW
FORJJLQJ
Ne
Y
er
LQVWDOODVFUHHQLQRURYHUWKHH[KDXVWGXFW7KLVFRXOG
FDXVHOLQWEXLOGXS
:DOOFDSVPXVWEHLQVWDOOHGDWOHDVWLQDERYHJURXQGOHYHO
RUDQ\RWKHUREVWUXFWLRQZLWKWKHRSHQLQJSRLQWHGGRZQ
SE
3
ARATION OF T
8
RNS
)RUEHVWSHUIRUPDQFHVHSDUDWHDOOWXUQVE\DWOHDVWIWRI
VWUDLJKWGXFWLQFOXGLQJGLVWDQFHEHWZHHQODVWWXUQDQGH[KDXVW
KRRG
T
8
RNS OTHER THAN
2QHWXUQRIRUOHVVPD\EHLJQRUHG
7ZRWXUQVVKRXOGEHWUHDWHGDVRQHWXUQ
(DFKWXUQRYHUVKRXOGEHWUHDWHGDVRQHWXUQ
SEA
/
ING OF
-
OINTS
$OOMRLQWVVKRXOGEHWLJKWWRDYRLGOHDNV7KHPDOHHQGRIHDFK
VHFWLRQRIGXFWPXVWSRLQWDZD\IURPWKHGU\HU
'RQRWDVVHPEOHWKHGXFWZRUNZLWKIDVWHQHUVWKDWH[WHQGLQWR
WKHGXFW7KH\ZLOOVHUYHDVDFROOHFWLRQSRLQWIRUOLQW
'XFWMRLQWVFDQEHPDGHDLUDQGPRLVWXUHWLJKWE\ZUDSSLQJ
WKHRYHUODSSHGMRLQWVZLWKGXFWWDSH
+RUL]RQWDOUXQVVKRXOGVORSHGRZQWRZDUGWKHRXWGRRUV
LQFKSHUIRRW
INS
8/
ATION
'XFWZRUNWKDWUXQVWKURXJKDQXQKHDWHGDUHDRULVQHDUDLU
FRQGLWLRQLQJVKRXOGEHLQVXODWHGWRUHGXFHFRQGHQVDWLRQDQG
OLQWEXLOGXS
WARNING
IN CANADA AND IN THE
8
NITED STATES
THE RE
48
IRED E
;
HA
8
ST D
8
CT
DIAMETER IS
IN
2mm
DO NOT
8
SE D
8
CT
/
ONGER THAN S
3
ECIFIED IN THE E
;
HA
8
ST
/
ENGTH TA
%/
E
8VLQJH[KDXVWORQJHUWKDQVSHFL¿HGOHQJWKZLOO
,QFUHDVHWKHGU\LQJWLPHVDQGWKHHQHUJ\FRVW
5HGXFHWKHGU\HUOLIH
$FFXPXODWHOLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG
The correct e
[
haust installation is YO
8
R RES
3
ONSI
%
I
/
ITY
3
ro
E
lems due to incorrect installation are not co
Y
ered
E
y
the
Z
arranty
5HPRYHDQGGLVFDUGH[LVWLQJSODVWLFRUPHWDOIRLOWUDQVLWLRQ
GXFWDQGUHSODFHZLWK8/OLVWHGWUDQVLWLRQGXFW
7KH
MA
;
IM
8
M A
//
OWA
%/
E
GXFWOHQJWKDQGQXPEHURI
EHQGVRIWKHH[KDXVWV\VWHPGHSHQGVXSRQWKHW\SHRIGXFW
QXPEHURIWXUQVWKHW\SHRIH[KDXVWKRRGZDOOFDSDQGDOO
FRQGLWLRQVQRWHGEHORZ7KHPD[LPXPGXFWOHQJWKIRUULJLG
PHWDOGXFWLVVKRZQLQWKHWDEOHEHORZ
EXHAUST LENGTH
4" DIA.
4"
4" DIA.
4" DIA.
2-1/2"
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
No. of 90º
Elbows
Rigid
Metal
Rigid
Metal
90 F eet
60 F eet
45 F eet
35 F eet
0
1
2
3
60 F eet
45 F eet
35 F eet
25 F eet
Use only for short
run installations