Specification Revised 3/10

Special Installation Requirements:
Stacked Installation: 

•  Bracket for stacking dryer, DSXH47EG/GG, order Pub. No. 14-A026 or STACKIT1WW at additional cost.

Undercounter installation: 

•  The WSSH300G and DSXH47EG/GG require a custom-sized countertop (36 inches to the underside of the countertop). 

 

No special washer or dryer top is required.

Alcove or Closet Installation: 

•  If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.
• The dryer MUST be exhausted to the outside.
•  Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 0" either side, 3" front and rear
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".
•  Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally 

distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area 

 

equally distributed.

•  No other fuel-burning appliance shall be installed in the same closet with a gas dryer.

Bathroom or Bedroom Installation: 

• The dryer MUST be exhausted to the outdoors.
•  The installation must conform with the local codes, or in the absence of 

 

local codes, with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.

Minimum Clearance other than Alcove or Closet Installations: 

• Minimum clearances to combustible surfaces 0" both sides, 3" rear.

For more information on venting kits and accessories,  

please call 1-800-GE-CARES.

DSXH47GG 

GE

®

 5.8 Cu. Ft. Extra-Large Capacity Frontload Gas Dryer

 

For answers to your Monogram,

® 

GE Profile

  

or GE

®

 appliance questions, visit our website  

at geappliances.com or call GE Answer Center

®

  

service, 800.626.2000.

Summary of Contents for DSXH47GG

Page 1: ...protected by a 30 amp circuit breaker or a time delay fuse is required Note Dryer wall outlet must be located within 36 of service cord entry and accessible when dryer is mounted in position Installation Information For complete information see installation instructions packed with your dryer SIDE VIEW 28 1 2 48 1 2 4 3 4 Optional Vent Knockout Door Open 90 4 3 8 REAR VIEW 27 5 2 1 4 36 Under Coun...

Page 2: ... otherwise ventilated and must contain a minimum of 60 sq in of open area equally distributed If this closet contains both a washer and a dryer doors must contain a minimum of 120 sq in of open area equally distributed No other fuel burning appliance shall be installed in the same closet with a gas dryer Bathroom or Bedroom Installation The dryer MUST be exhausted to the outdoors The installation ...

Page 3: ... of 4 rigid aluminum or galvanized duct which can be tolerated is shown in the table A turn of 45 or less may be ignored Two 45 turns within the duct length should be treated as a 90 elbow A turn over 45 should be treated as a 90 elbow Dryers must be exhausted to the outside Caution For personal safety do not terminate exhaust into a chimney under any enclosed house floor crawl space or into an at...

Page 4: ...our Temperature Options Provides the right temperature for the right drying results On Off End Of Cycle Signal Can be turned on so you can hear it from another room or turned off when you do not want to disturb others Four Auto Dry Cycles A variety of fast and flexible options for drying clothes Sensor Dry Continually monitors moisture levels to help clothes look better longer Interior Dryer Light...

Reviews: