Specification Created 2/10

Listed by 

Underwriters 

Laboratories

DSKS333EC 

GE Spacemaker

® 

Stationary Dryer

Dimensions and Installation Information (in inches) 

Dryer Note:
Dryer wall outlet must be locted within 36" of service cord entry and accessible 
when dryer is mounted in position.

33-1/4

23-7/8

24-1/2

DSKS333EC

Special Installation Requirements
Alcove or Closet Installation:
 

•  If your dryer is approved for installation in an alcove or closet, it will be stated on 

a label on the dryer back.

• The dryer MUST be exhausted to the outside.

 

•  Minimum clearances between dryer cabinet and adjacent walls or other 

surfaces are: 
    0" either side 

       3" front and rear

• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”.

 

•  Closet doors must be louvered or otherwise ventilated and must contain a 

minimum of 60 sq. in. of open area equally distributed. If this closet contains 

both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open 
area equally distributed.

•  No other fuel-burning appliance shall be installed in the same closet with 

 

a gas dryer.

Bathroom or Bedroom Installation:

• The dryer MUST be exhausted to the outdoors.

 

•  The installation must conform with the local codes, or in the absence of local 

codes, with the National Electric Code and National Fuel Gas Code, ANSI Z223 

for gas dryers.

Minimum Clearances other than Alcove or Closet Installation:

•  Minimum clearances to combustible surfaces

 

    0" both sides

       3" rear

Above illustration intended for dimensional reference only. 
Refer to photography for actual product appearance.