MDS 05-4670A01, Rev. E
SD Series Reference Manual (x710 Mode)
37
The SNR is an indication of the received signal quality. A value of
10 dB represents a very poor signal. A value of 24 dB represents a very
good signal.
When the SNR command is used, it causes the
DIAG.
port to enter an
update mode, and the signal-to-noise ratio is updated and redisplayed
every 2 seconds. The SNR continuously updates until the
key is
pressed.
SPECTRUM [xxx.xx]
Internal Spectrum
Analyzer
Activates the built-in spectrum analyzer tool (see Figure 18) that can be shown
on a connected PC. This tool is helpful in diagnosing interference problems on
or near your channel frequency.
Access the spectrum analyzer by entering
spectrum
at the command prompt. A
display appears showing detected signals on your
current channel
.
Optionally, you can specify a frequency at the command prompt to view the
surrounding spectrum of that frequency. To do this, enter
spectrum xxx.xx
,
where
xxx.xx
is the frequency in MHz.
A typical spectrum analyzer display is shown in Figure 18. The display creates
a received signal strength indication (RSSI) vs. frequency plot for the fre-
quency and surrounding signals. By analyzing the display, you can determine
the presence of other signals near the transceiver’s operating frequency. This
information can be helpful in troubleshooting interference problems.
Invisible place holder
Figure 18. Internal Spectrum Analyzer Display
SQUELCH [AUTO, BYPASSED]
Squelch Operation
Set or show analog squelch bypass.
SREV
Software/Firmware
Revision Level
This command shows the software revision level of the transceiver firm-
ware.
ENTER
Summary of Contents for DS-SD4-1
Page 10: ...viii SD Series Reference Manual x710 Mode MDS 05 4670A01 Rev E ...
Page 69: ...MDS 05 4670A01 Rev E SD Series Reference Manual x710 Mode 59 NOTES ...
Page 70: ...60 SD Series Reference Manual x710 Mode MDS 05 4670A01 Rev E ...
Page 74: ...MDS 05 4670A01 Rev E SD Series Reference Manual x710 Mode I 4 ...