– 26 –
L3 Dryer - Gas Model
Note: See schematic for proper switch connections.
1. Other factors contributing to long dry times or clothes conditions include load size, number of
large or bulky items, ambient temperature, room size (if not exhausted outdoors), wetness of
clothes, and washer rinse temperature.
2. Small loads (less than 3 lb) may develop static, causing clothes to cling to the drum surface
(no tumble) and resulting in wrinkles, shrinkage, or melting. Use a fabric softener in the
washer or dryer, or add two large bath towels to act as a buffer when drying.
GEA00550
L1
BLACK
BLACK
BLACK
BLACK
BROWN
RED
IDLER SWITCH
YELLOW/BLACK
BLACK
WHITE
WHITE
PINK
GRAY
PINK
LOWER ROD
MOV
UPPER ROD
MOV
GRAY
M6
START
DRUM/BLOWER MOTOR
OVERLOAD
PROTECTOR
RUN
M5
M4
WHITE
M1
M2
BROWN/YELLOW
GREEN
BROWN/YELLOW
PURPLE
PURPLE
BLUE
BLUE
PURPLE
YELLOW
YELLOW
YELLOW/BLACK
ORANGE
ORANGE
ORANGE
BROWN/WHITE
BROWN/WHITE
BLACK
BLACK
BLACK
9K
9K
9K
GAS VALVE
SAFETY
COIL
SAFETY
ULTRACARE
CONTROL
INLET
DRUM
OUTLET
BOOSTER
COIL
MAIN
COIL
IGNITOR
DETECT
YELLOW
BLACK
YELLOW
ELECTRONIC DRYER
POWER BOARD
N
DOOR SWITCH
NC
NO
N
2A
L1
10
16
9
7
8
6
1
J
1
3
4
5
6
COM
DRUM LAMP
TRANSFORMER
POWER/START
RELAY
K1-no
BIAS
RELAY
K3-no
GAS VALVE
RELAY
K4-no
OUTLET/ULTRACARE
BIAS RELAY
K2-no
ULTRACARE RELAY
(GENTAL HEAT)
K5-no
G8P
G8P
G5S
G5S
G8P
TRIMMER
SOLDER TRACES ON PC BOARD
GANGED SWITCH
COMMERCIAL OMITTED
LEGEND
Caution: Label all wires prior to disconnection when
servicing the controls. Wiring errors can cause
improper and dangerous operation. Verify proper
operation after servicing.