Page 1: ...all a clothesdryer with flexible plastic ducting materials If flexiblemetal semi rigidor foil type duct is installed it must be ULlisted and installedin accordance with the instructions found in ConnectingThe DryerToHouseVent onpage 6 of this manual Flexibleventing materials are knownto collapse beeasiiy crushed and trap lint Theseconditionswilt obstruct dryerairflow and increasethe risk of fire D...

Page 2: ...is drger for use with propane LP gas ALL CONVERSIONSMUST BEMADE BY PROPERLY TRAINED AND QUALIFIED PERSONNELAND IN ACCORDANCEWITH LOCAL CODESAND ORDINANCE REQUIREMENTS The dryer must be disconnected from the gas supply piping system during any pressure testing of that system at a test pressure in excess of O 5 PSI 3 4 KPa The dryer must be isolated from the gas supply piping system bg closing the e...

Page 3: ...UTION Use adapters as shown Connector nuts must not be connected directly to pipe threads APPLYPIPECOMPOUND TOTHEADAPTER AND DRYER GASINLET GAS LINE USING TWO _ I TIGHTENTHE FLEXIBLE _ ADJUSTABLEWRENCHE _ APPLYPIPECOMPOUND TO ALL MALETHREADS TIGHTEN ALL CONNECTIONS USINGTWO ADJUSTABLE WRENCHES DO NOT OVERTORQUE GAS CONNECTIONS I 1 LEAK TEST WARNING NEVER USE ANOPEN FLAME TO TEST FOR GAS LEAKS OPEN...

Page 4: ...the warranty Removeanddiscardexisting plastic or metalfoil transition duct and replacewith ULlistedtransition duct TheMAXIMUMALLOWABLE duct length and number of bendsof the exhaust systemdependsuponthe type of duct number of turns the type of exhausthood wallcap and all conditions noted below The maximumduct length for rigid metal duct is shownin the table below EXHAUST LENGTH RECOMMENDED MAXIMUM ...

Page 5: ... hazard Do not assemble ductwork with any fasteners that extend into the duct These fasteners can accumulate lint creating a potential fire hazard Do not obstruct incoming or exhausted air Provide an access for inspection and cleaning of the exhaust system especially at turns and joints Exhaust system shall be inspected and cleaned at least once year THIS DRYER COMES READY FOR REAR EXHAUSTING IF S...

Page 6: ...t to the exhaust pipewith the other clamp ELBOW HIGHLY RECOMMENDED _WS HIGHLY RECOMMENDE_ DO EXCESSIVE EXHAUST LENGTH LCOVE OR CLOSETINSTALLATION If your dryer is approvedfor installation in an alcoveor closet it will bestated on a labelon the dryer back Thedryer MUSTbe ventedto the outdoors Seethe EXHAUST INFORMATION section Minimum clearancebetween dryercabinet and adjacent wallsor other surface...

Page 7: ...ear opening locate the tab in the middle of the appliance base Lift the tab to about 450 using a flat blade screwdriver ADDING NEW DUCT FIXING HOLE PORTION A LEFT SIDE EXHAUST Reconnectthe cut portion A of the duct to the blower housing Makesure that the shortened duct is aligned with the tab inthe base Usethe screw saved previouslgto secure the duct in place through the tab on the appliance base ...

Page 8: ...ape otherwise they may separate and cause a safety hazard ADDING COVER PLATE TO REAR OF CABINET PLATE KITWEII454 Connect standard metal elbows and ducts to complete the exhaust system Cover back opening with a plate Kit WEllV1454 available from your local service provider Place dryer in final location WARNING NEVER LEAVE THE BACK OPENING WITHOUT THE PLATE CHANGING DIRECTION OF DOOR OPENING REMOVE4...

Page 9: ...er is in place and attach the other end of the dryer s long inlet hose to the fill valve connector at the bottom of the dryer back panel Tighten by hand until firmly seated 7 Using pliers tighten all the couplings with an additional two thirds turn NOTE Do not overtighten Damage to the couplings may result CONNECTING INLET HOSES cont 8 Turn the water faucet on 9 Check for leaks around the Y connec...