Chapter 1. Installation
12
DigitalFlow™ GF868 Startup Guide (1 and 2-Channel)
1.7.4e Wiring the Foundation Fieldbus Network
Fieldbus network connections are made at J8/J9, pins 1 and 2 (see Figure 5). Optionally, a shield can be connected to
J8/J9 pin 3, depending on the network wiring. Connector J8 or J9 will be installed depending on the option ordered by
the customer.
No connections are made to J8/J9, pins 7 and 9, under normal operation. If it is desired to reset the network board to
factory defaults:
1.
Connect a jumper between J8/J9 pin 7 and pin 9.
2.
Power cycle the instrument.
3.
Ten seconds after the power has been restored to the unit, remove the jumper to return the network board to normal
operation.
Figure 5: Network Connections - Standard Option Interior
1
9
J8
1
9
J9