Special Installation Requirements:
Stacked Installation: 

• Brackets for stacking dryer over washer are included with the washer.

Alcove or Closet Installation: 

•  If your dryer is approved for installation in an alcove or closet, it will be  

stated on a label on the dryer back.

• The dryer MUST be exhausted to the outside.
•  Minimum clearances between dryer cabinet and adjacent walls or other  

surfaces are: 0" either side, 3" front and rear

• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".
•  Closet doors must be louvered or otherwise ventilated and must contain a  

minimum of 60 sq. in. of open area equally distributed. If this closet contains  
both a washer and a dryer, doors must contain a minimum of 120 sq. in. of  
open area equally distributed.

•  No other fuel-burning appliance shall be installed in the same closet with  

a gas dryer.

Bathroom or Bedroom Installation: 

• The dryer MUST be exhausted to the outdoors.
•  The installation must conform with the local codes, or in the absence of  

local codes, with the National Fuel Gas Code, ANSI Z223.

Minimum Clearance other than Alcove or Closet Installations: 

• Minimum clearances to combustible surfaces 0" both sides, 3" rear.

For more information on venting kits and accessories,  

please call 1-800-GE-CARES.

Stacked Dimensions (in inches) 

80-1/8

27

10-3/8

27

13-3/8

28-3/4

Pedestal Dimensions  (in inches) 
SBSD107HWW - white 

SBSD137HWW - white 

SBSD137HGG - granite 

SBSD137HBB - black

These optional 10" and 13" 
pedestals raise the door opening 
and height of the washer or dryer. 
Feet on 10" pedestal allow it to 
adjust to 10-3/8" height. Feet on 
13" pedestal allow it to adjust to 
13-3/8" height.

Listed by 

Underwriters 

Laboratories

Specification Revised 10/07

360462

DCVH660EH 

GE

®

 7.0 Cu. Ft. Super Capacity Frontload Electric Dryer

 

Summary of Contents for DCVH660EH

Page 1: ...cuit Requirements An individual properly grounded branch circuit protected by a 30 amp circuit breaker or a time delay fuse is required Note Dryer wall outlet must be located within 36 of service cord entry and accessible when dryer is mounted in position Installation Information For complete information see installation instructions packed with your dryer 27 1 5 8 41 1 2 31 1 8 5 1 2 3 3 4 Electr...

Page 2: ...m of 120 sq in of open area equally distributed No other fuel burning appliance shall be installed in the same closet with a gas dryer Bathroom or Bedroom Installation The dryer MUST be exhausted to the outdoors The installation must conform with the local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 Minimum Clearance other than Alcove or Closet Installations Mi...

Page 3: ...uct A turn of 45 or less may be ignored Two 45 turns within the duct length should be treated as a 90 elbow A turn over 45 should be treated as a 90 elbow Exhausting the dryer to the outside is strongly recommended to prevent large amounts of moisture and lint from being blown into the room Gas dryers or any dryer located in a closet must be exhausted to the outside Caution For personal safety do ...

Page 4: ... quiet operation Adjustable End Of Cycle Signal Alerts you when cycle is done saving time between loads Multiple Dry Cycles Deliver optimal drying results Antibacterial Option Certified by the NSF to reduce up to 99 9 of certain types of bacteria Five Heat Selections Temperatures are matched to fabric type for better fabric care DuraDrum Provides long lasting dependability and durability Model DCV...

Reviews: