GE DCVH640EJ Dimensions And Installation Information Download Page 2

For answers to your Monogram,

® 

GE Profile

 or  

GE

®

 appliance questions, visit our website at 

ge.com or call GE Answer Center

®

 service,  

800.626.2000.

360451

Specification Revised 1/08

Special Installation Requirements:
Stacked Installation: 
• Brackets for stacking dryer over washer are included with the washer.
Alcove or Closet Installation: 
•  If your dryer is approved for installation in an alcove or closet, it will be  

stated on a label on the dryer back.

• The dryer MUST be exhausted to the outside.
•  Minimum clearances between dryer cabinet and adjacent walls or other  

surfaces are: 0" either side, 3" front and rear

• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".
•  Closet doors must be louvered or otherwise ventilated and must contain a  

minimum of 60 sq. in. of open area equally distributed. If this closet contains  
both a washer and a dryer, doors must contain a minimum of 120 sq. in. of  
open area equally distributed.

•  No other fuel-burning appliance shall be installed in the same closet with  

a gas dryer.

Bathroom or Bedroom Installation: 
• The dryer MUST be exhausted to the outdoors.
•  The installation must conform with the local codes, or in the absence of  

local codes, with the National Fuel Gas Code, ANSI Z223.

Minimum Clearance other than Alcove or Closet Installations: 
• Minimum clearances to combustible surfaces 0" both sides, 3" rear.
For more information on venting kits and accessories,  

please call 1-800-GE-CARES.

Stacked Dimensions (in inches) 

80-1/8

DCVH640EJ 

GE

®

 7.0 Cu. Ft. Super Capacity Frontload Electric Dryer

 

Listed by 

Underwriters 

Laboratories

Summary of Contents for DCVH640EJ

Page 1: ...cuit Requirements An individual properly grounded branch circuit protected by a 30 amp circuit breaker or a time delay fuse is required Note Dryer wall outlet must be located within 36 of service cord entry and accessible when dryer is mounted in position Installation Information For complete information see installation instructions packed with your dryer 27 1 5 8 41 1 2 31 1 8 5 1 2 3 3 4 Electr...

Page 2: ...set doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq in of open area equally distributed If this closet contains both a washer and a dryer doors must contain a minimum of 120 sq in of open area equally distributed No other fuel burning appliance shall be installed in the same closet with a gas dryer Bathroom or Bedroom Installation The dryer MUST be exhausted to t...

Page 3: ...le ducts are less than for rigid duct A turn of 45 or less may be ignored Two 45 turns within the duct length should be treated as a 90 elbow A turn over 45 should be treated as a 90 elbow Exhausting the dryer to the outside is strongly recommended to prevent large amounts of moisture and lint from being blown into the room Gas dryers or any dryer located in a closet must be exhausted to the outsi...

Page 4: ...ng inside for easy loading and unloading Quiet By Design Engineered for quiet operation Adjustable End of Cycle Signal Alerts you when cycle is done saving time between loads Multiple Dry Cycles Deliver optimal drying results Antibacterial Option Certified by the NSF to reduce up to 99 9 of certain types of bacteria 5 Heat Selections Offer enhanced drying performance and fabric care DuraDrum Provi...

Reviews: