D20 ME Jumper Options, 

Continued 

JP1 -  
VME Control 

This jumper sets the Master or Slave function of the board on the VME bus. 

Note: 

Single-node D20 systems are 

always

 set to Master. 

   

JP2 -  
VME Address 

JP2 is a group of four jumpers that set the VME bus address of the board. The 
address should reflect the board location in a D200 CCU chassis. 

Example: The board with address 1 will be the lead node, with nodes 2 

through 8 positioned to the right of the lead node. 

Note: 

Single-node D20s are set to address 0 (all jumpers IN). 

   

JP3-1 and  
JP3-2 
RTC Options 

These two jumpers determine the 

R

eal-

T

ime 

C

lock (RTC) source for each 

D20 ME board in a CCU: 

• 

Single-node D20s and the first, or 

lead,

 node of a D200 both use an internal 

clock. 

• 

Non-lead nodes of a D200 synchronize the clocks to the clock of the lead node. 

  

Table: JP4 -  
Watchdog 
Enable/Disable 

This two-position jumper enables or disables the hardware Watchdog. 

Note: 

Never leave the Watchdog disabled during normal D20 ME 
operation. 

Jumper Position 

Function 

pin 1 to 2 

(center) 

Disables the hardware Watchdog. 

JP4 

Pin 1 = SLOWCK 
Pin 3 = /WD 

pin 3 to 2 

(center) 

Enables the hardware Watchdog. 

   

Table: JP8 –  
Battery Backup 
Enable/Disable 

The D20 ME card has two 3.6V Lithium batteries, TADIRAN

TM

 TL-2150 or 

equivalent, to maintain NVRAM contents in the event of a power failure. 

Important:  Disconnect the batteries if you are storing the board for extended 

periods of time. 

Jumper Position 

Function 

pin 1 to 2 

Disconnects the batteries from the NVRAM 

pin 3 to 2 

Connects the batteries to the NVRAM 

JP8 

pins 4 to 5 

Always jumpered 

 

 

 994-0025-1.00-8 

General 

 Full 

Release 

 

Summary of Contents for D20 ME

Page 1: ...g GE Power Systems D20 ME Quick Start Guide Document Number 994 0025 Version 1 00 Revision 8 Date 03 11 24 Classification General Full Release ...

Page 2: ...n purposes only Reproduction in whole or in part to create working hardware or software for other than General Electric Canada Inc products is strictly prohibited except as permitted by written license agreement with General Electric Canada Inc TRADEMARK NOTICES GE and gare trademarks and service marks of General Electric Company WESDAC is a registered trademark of General Electric Company General...

Page 3: ...E Power Systems D20 ME Quick Start Guide Contents Topic See Page D20 ME Jumper Options 4 Introduction to Downloading Flash Code 7 Code Download D20 ME D20 Base 9 Code Download D20 ME CCU 11 994 0025 1 00 8 General 3 Full Release ...

Page 4: ...e D20 ME Jumper Options D20 ME Board Layout This diagram shows the location of some of the optional jumpers and components found on the D20 ME cards Part 526 2004 and 526 2005 JP1 JP3 BootROM JP2 JP4 JP8 994 0025 1 00 8 General 4 Full Release ...

Page 5: ...OUT IN Multi Node For D20 or D200 Board Function JP1 Master Slave JP2 VME Address Bits 4 3 2 1 JP3 1 RTC SERCLOCK JP3 2 RTC BRTC Node 1 OUT IN IN IN OUT IN IN Node 2 IN IN IN OUT IN IN OUT Node 3 IN IN IN OUT OUT IN OUT Node 4 IN IN OUT IN IN IN OUT Node 5 IN IN OUT IN OUT IN OUT Node 6 IN IN OUT OUT IN IN OUT Node 7 IN IN OUT OUT OUT IN OUT Node 8 IN OUT IN IN IN IN OUT Notes Single Node is the f...

Page 6: ...ad node of a D200 both use an internal clock Non lead nodes of a D200 synchronize the clocks to the clock of the lead node Table JP4 Watchdog Enable Disable This two position jumper enables or disables the hardware Watchdog Note Never leave the Watchdog disabled during normal D20 ME operation Jumper Position Function pin 1 to 2 center Disables the hardware Watchdog JP4 Pin 1 SLOWCK Pin 3 WD pin 3 ...

Page 7: ...nstalled you need to determine the type of D20 ME module before downloading the Flash code Note The xx in the Label column is the software revision number Module Type BootROM Label D20 ME D20 Base SBU0000 xx D20 ME CCU SBU0001 xx Prerequisites for Code Download You need the following items to successfully load a Flash code file into a D20 ME module Windows PC with HyperTerminal or equivalent commu...

Page 8: ...ile For more information on upgrading from earlier versions refer to the D20 ME Processor Module Installation and Operations Guide Procedure Setup To set up the equipment for downloading code files to the D20 ME Step Action Configure and Connect PC to D20 ME 1 Connect a WESMAINT cable from the PC s COM port to the D20 ME s front panel WESMAINT serial port 2 Start Windows HyperTerminal communicatio...

Page 9: ...nfiguration file is overwritten with a default configuration The 68K Monitor is initiated 4 Press ENTER In the login dialog type westronic and press ENTER then type rd and press ENTER Result After a Welcome message the D20M prompt displays 5 Type sp to suspend all processes running on the D20 ME 6 Type erase to clear the Flash This will take several seconds Result Flash Erased is displayed when co...

Page 10: ...press ENTER to ready the D20 ME to receive the downloadable code file 11 Click Transfer Send Text File from menu bar Result A dialog box opens prompting you to locate the Down shx file that you wish to download 12 Select the correct file and click Open to start the transfer Result The file transfer may take from less than 10 minutes to over 30 minutes depending on the communication speed selected ...

Page 11: ...type westronic and press ENTER then type rd and press ENTER Result After a Welcome message the D20MES prompt displays 5 Type sp to suspend all processes running on the D20 ME 6 Type erase to clear the Flash This will take several seconds Result The monitor displays the messages below and then returns the D20MES prompt Erasing FLASH memory Checking FLASH contents Optional Step 1 To speed up communi...

Page 12: ... Code File 10 Type dl and press ENTER to ready the D20 ME to receive the downloadable code file 11 Click Transfer Send Text File from menu bar Result A dialog box opens prompting you to locate the Down shx file that you wish to download 12 Select the correct file and click Open to start the transfer Result The file transfer may take from less than 10 minutes to over 40 minutes depending on the com...

Page 13: ...cation code for each D20 ME module in a multi node system can be the same or different for one or more of the modules The download procedure is the same for a multi node system as for a single node repeat the procedure for each node Note Do not restart i e Boot the multi node system until you have finished downloading code to all the D20 ME cards 994 0025 1 00 8 General 13 Full Release ...

Reviews: