B-14
C60 Breaker Protection System
GE Multilin
B.4 MEMORY MAPPING
APPENDIX B
B
07E8
...Repeated for IEC103 Command 27
07EC
...Repeated for IEC103 Command 28
07F0
...Repeated for IEC103 Command 29
07F4
...Repeated for IEC103 Command 30
07F8
...Repeated for IEC103 Command 31
07FC
...Repeated for IEC103 Command 32
Digital Counter States Actual Values (Read Only Non-Volatile) (8 modules)
0800
Digital Counter 1 Value
-2147483647 to
2147483647
---
1
F004
0
0802
Digital Counter 1 Frozen
-2147483647 to
2147483647
---
1
F004
0
0804
Digital Counter 1 Frozen Time Stamp
0 to 4294967295
---
1
F050
0
0806
Digital Counter 1 Frozen Time Stamp us (microsecond part
of time stamp)
0 to 4294967295
---
1
F003
0
0808
...Repeated for Digital Counter 2
0810
...Repeated for Digital Counter 3
0818
...Repeated for Digital Counter 4
0820
...Repeated for Digital Counter 5
0828
...Repeated for Digital Counter 6
0830
...Repeated for Digital Counter 7
0838
...Repeated for Digital Counter 8
FlexStates (Read Only)
0900
FlexState Bits (16 items)
0 to 65535
---
1
F001
0
Element States (Read Only)
1000
Element Operate States (64 items)
0 to 65535
---
1
F502
0
User Displays Actuals (Read Only)
1080
Formatted user-definable displays (16 items)
---
---
---
F200
(none)
Modbus User Map Actuals (Read Only)
1200
User Map Values (256 items)
0 to 65535
---
1
F001
0
Element Targets (Read Only)
14E0
Target Sequence
0 to 65535
---
1
F001
0
14E1
Number of Targets
0 to 65535
---
1
F001
0
Element Targets (Read/Write)
14E2
Target to Read
0 to 65535
---
1
F001
0
Element Targets (Read Only)
14E3
Target Message
---
---
---
F200
“.”
Contact Input/Output States (Read Only)
1500
Contact Input States (6 items)
0 to 65535
---
1
F500
0
1508
Virtual Input States (8 items)
0 to 65535
---
1
F500
0
1510
Contact Output States (4 items)
0 to 65535
---
1
F500
0
1518
Contact Output Current States (4 items)
0 to 65535
---
1
F500
0
1520
Contact Output Voltage States (4 items)
0 to 65535
---
1
F500
0
1528
Virtual Output States (6 items)
0 to 65535
---
1
F500
0
1530
Contact Output Detectors (4 items)
0 to 65535
---
1
F500
0
Remote Input/Output States (Read Only)
1540
Remote Device States (2 items)
0 to 65535
---
1
F500
0
1542
Remote Input States (4 items)
0 to 65535
---
1
F500
0
1550
Remote Devices Online
0 to 1
---
1
F126
0 (No)
1551
Remote Double-Point Status Input 1 State
0 to 3
---
1
F605
3 (Bad)
1552
Remote Double-Point Status Input 2 State
0 to 3
---
1
F605
3 (Bad)
1553
Remote Double-Point Status Input 3 State
0 to 3
---
1
F605
3 (Bad)
1554
Remote Double-Point Status Input 4 State
0 to 3
---
1
F605
3 (Bad)
1555
Remote Double-Point Status Input 5 State
0 to 3
---
1
F605
3 (Bad)
Platform Direct Input/Output States (Read Only)
15C0
Direct Input States (6 items)
0 to 65535
---
1
F500
0
Table B–10: MODBUS MEMORY MAP (Sheet 6 of 66)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Summary of Contents for C60
Page 10: ...x C60 Breaker Protection System GE Multilin TABLE OF CONTENTS ...
Page 30: ...1 20 C60 Breaker Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 420: ...5 284 C60 Breaker Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 466: ...8 4 C60 Breaker Protection System GE Multilin 8 1 FAULT LOCATOR 8 THEORY OF OPERATION 8 ...
Page 478: ...9 12 C60 Breaker Protection System GE Multilin 9 6 DISPOSAL 9 MAINTENANCE 9 ...
Page 492: ...A 14 C60 Breaker Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Page 648: ...E 10 C60 Breaker Protection System GE Multilin E 1 OVERVIEW APPENDIX E E ...
Page 660: ...F 12 C60 Breaker Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Page 670: ...H 8 C60 Breaker Protection System GE Multilin H 2 ABBREVIATIONS APPENDIX H H Z Impedance Zone ...
Page 672: ...H 10 C60 Breaker Protection System GE Multilin H 3 WARRANTY APPENDIX H H ...
Page 682: ...x C60 Breaker Protection System GE Multilin INDEX ...