GE Baker Hughes Reuter-Stokes Flame Tracker... Operation And Maintenance Manual Download Page 2

FS-9006OM 

– REV K 

 

ii 

 

 

NOTICE 

All content and material  in this Manual (including, without limitation, text, design, graphics,  logos, icons, 

images, code and software, as well as the selection and arrangement thereof) is confidential and proprietary, 

the exclusive property of and owned by Reuter-Stokes, LLC. and is protected by copyright, trademark and 

other  applicable  laws.    Any  use  of  content  and  material  in  this  Manual,  including  but  not  limited  to  the 

modification, distribution, transmission, performance, broadcast, publication, uploading, licensing, reverse 

engineering, transfer or sale of, or the creation of derivative works from, any material, information, software, 

products  or  services  obtained  from  the  content  and  material  in  this  Manual,  or  use  thereof  for  purposes 

competitive to Reuter-Stokes, LLC., is expressly prohibited.  

WHILE  EVERY  ATTEMPT  HAS  BEEN  MADE  TO  ASSURE  THE  COMPLETENESS,  ACCURACY  AND 

TIMELINESS OF THE CONTENT AND MATERIAL IN THIS MANUAL, IT IS PROVIDED ON AN "AS IS" AND "AS 

AVAILABLE" BASIS.  REUTER-STOKES, LLC. EXPRESSLY DISCLAIMS ALL WARRANTIES OF ANY KIND, 

WHETHER  EXPRESS  OR  IMPLIED,  INCLUDING  BUT  NOT  LIMITED  TO  THE  IMPLIED  WARRANTIES  OF 

MERCHANTABILITY  AND  FITNESS  FOR  A  PARTICULAR  PURPOSE  AND  ANY  WARRANTIES  THAT  THE 

CONTENT  AND  MATERIAL  IN  THIS  MANUAL  IS  NONINFRINGING,  AS  WELL  AS  WARRANTIES  IMPLIED 

FROM A COURSE OF PERFORMANCE OR COURSE OF DEALING; THE MATERIALS IN THIS MANUAL WILL 

BE  ERROR-FREE;  OR  THAT  THE  MATERIALS  IN  THIS  MANUAL  WILL  BE  COMPLETE,  ACCURATE  OR 

TIMELY. NO ADVICE OR INFORMATION, OBTAINED BY YOU FROM REUTER-STOKES, LLC. OR THROUGH 

THE CONTENT AND MATERIAL IN THIS MANUAL SHALL CREATE ANY WARRANTY OF ANY KIND. REUTER-

STOKES,  LLC.  DOES  NOT MAKE  ANY  WARRANTIES  OR  REPRESENTATIONS  REGARDING  THE  USE  OF 

THE CONTENT AND MATERIAL IN THIS MANUAL IN TERMS OF THEIR COMPLETENESS, CORRECTNESS, 

ACCURACY, ADEQUACY, USEFULNESS, TIMELINESS, RELIABILITY OR OTHERWISE. 

YOU ACKNOWLEDGE AND AGREE THAT YOU ASSUME FULL RESPONSIBILITY FOR YOUR USE OF THE 

CONTENT AND MATERIAL IN THIS MANUAL.  YOU ACKNOWLEDGE AND AGREE THAT YOUR USE OF THE 

CONTENT AND MATERIAL IN THIS MANUAL IS AT YOUR OWN RISK.  YOU ACKNOWLEDGE AND AGREE 

THAT, TO THE FULLEST EXTENT PERMITTED BY APPLICABLE LAW, REUTER-STOKES, LLC. WILL NOT 

BE  LIABLE  FOR  ANY  DIRECT,  INDIRECT,  PUNITIVE,  EXEMPLARY,  INCIDENTAL,  SPECIAL, 

CONSEQUENTIAL OR OTHER DAMAGES ARISING OUT OF OR IN ANY WAY RELATED TO THE CONTENT 

AND  MATERIAL  IN  THIS  MANUAL,  WHETHER  BASED  ON  CONTRACT,  TORT,  STRICT  LIABILITY  OR 

OTHERWISE. THIS DISCLAIMER APPLIES, WITHOUT LIMITATION, TO ANY DAMAGES OR INJURY ARISING 

FROM ANY FAILURE OF PERFORMANCE, ERROR, OMISSION, YOUR LOSS OF PROFITS, DESTRUCTION, 

AND ANY OTHER TANGIBLE OR INTANGIBLE LOSS.  

Copyright © 2017 Baker Hughes, a GE company.  

 

Contains Baker Hughes, a GE company Confidential Information. 

Summary of Contents for Baker Hughes Reuter-Stokes Flame Tracker...

Page 1: ...FS 9006 GE 07482SOCNL44819P01 Operation and Maintenance Manual FS 9006OM Rev K November 2017 www gemeasurement com A trademark of Baker Hughes a GE company LLC 2017 Baker Hughes a GE company All righ...

Page 2: ...G AS WELL AS WARRANTIES IMPLIED FROM A COURSE OF PERFORMANCE OR COURSE OF DEALING THE MATERIALS IN THIS MANUAL WILL BE ERROR FREE OR THAT THE MATERIALS IN THIS MANUAL WILL BE COMPLETE ACCURATE OR TIME...

Page 3: ...4 WRTR L Lombardo REV E DATE 06 25 10 ECN 40293054 WRTR R Martin REV F DATE 04 24 13 ECN 77469075 WRTR J Hashmi REV G DATE 12 18 15 ECN 500000157848 WRTR J Hashmi REV H DATE 02 22 16 ECN 500000204318...

Page 4: ...Ta 235 C T2 with cooling coil South Korea KTL hazardous area mark Customs Union hazardous area mark China hazardous area mark Brazil INMETRO hazardous area mark India hazardous area approved Taiwan ha...

Page 5: ...by wrenching on the body Always use the 1 3 8 inch mounting nut Wrenching on the body may breach the seal Breaching the seal of the sensor will cause loss of the inert fill gas and render the sensor u...

Page 6: ...TERCONNECTING CABLE RS E2 0279PXXX OR 362A1053PXXX 2 1 2 REFERENCE 3 1 3 GENERAL DESCRIPTION 4 2 SENSOR 4 3 INSTALLATION 5 3 1 MECHANICAL 5 3 2 ELECTRICAL 7 3 3 CONNECTOR PINOUT 8 3 4 SENSOR CHECKOUT...

Page 7: ...s III size 15 5 pin Sensor Silicon Carbide photodiode Window Sapphire Operating Sensitivity 5 mA 1x1010 photons in2 sec 310 nm Output 4 20 mA dc Max 21 mA Response Time 25 milliseconds Power Requireme...

Page 8: ...e 1 02 mm 19 strand nickel plated copper Insulation Teflon PTFE Shield Jacket 36 gauge 0 127 mm nickel plated copper braid Extruded PFA Armor Stainless steel braid Connector MIL C 38999 series III she...

Page 9: ...FS 9006OM REV K 3 1 2 REFERENCE...

Page 10: ...n a number of GE gas turbine installations 2 SENSOR Figure 1 is a block diagram of the SiC Flame Sensor The sensor has a sapphire window that is transparent to UV light and can withstand the compresso...

Page 11: ...1 5 m sec or greater at a temperature of 50 F 10 C or less above outside ambient Under these conditions the sensors will operate at outside ambient temperatures up to 140 F 60 C Air cooling with press...

Page 12: ...pplied below the 2nd thread If Never Seez is applied to the face of the sight tube upon heating it can fog the window of the Flame Sensor 3 Inspect the window and clean with Isopropanol soaked swab If...

Page 13: ...er or to earth ground at any location The inner shields should be individually jumpered through all junction boxes and connected to the proper ground terminal at the Controller The polarity of the cab...

Page 14: ...see zero flame intensity signal and with a flashlight to see a positive reading With no light the reading should be 3 7 to 4 1 milliamps while with most flashlights the reading should be above 8 milli...

Page 15: ...ize compound should be applied to the mounting thread prior to reinstallation of the sensor 5 TROUBLESHOOTING 5 1 WARNING Do not disconnect connector while circuit is energized or live unless area is...

Reviews: