PanaFlow™ LC User’s Manual
51
Chapter 3. Programming
Table 11: Frequency Output Error Handling with Path Error Handling set to ON
Ch1 in Error Ch2 in Error Ch3 in Error
Error displayed in
Meter
Expected
Composite
Volumetric(Act)
behavior
Analog Output
Response
No
No
No
No Error
Measured
Composite
Volumetric(Act)
Frequency
proportional to the
Measured Composite
Volumetric(Act)
Yes
No
No
E22:
SingleChAccuracy
Measured
Composite
Volumetric(Act)
Frequency
proportional to the
Measured Composite
Volumetric(Act)
No
Yes
No
E22:
SingleChAccuracy
Measured
Composite
Volumetric(Act)
Frequency
proportional to the
Measured Composite
Volumetric(Act)
No
No
Yes
E22:
SingleChAccuracy
Measured
Composite
Volumetric(Act)
Frequency
proportional to the
Measured Composite
Volumetric(Act)
Yes
Yes
No
E23:
MultiChAccuracy
Measured
Composite
Volumetric(Act)
Frequency
proportional to the
Measured Composite
Volumetric(Act)
No
Yes
Yes
E23:
MultiChAccuracy
Measured
Composite
Volumetric(Act)
Frequency
proportional to the
Measured Composite
Volumetric(Act)
Yes
No
Yes
E23:
MultiChAccuracy
Measured
Composite
Volumetric(Act)
Frequency
proportional to the
Measured Composite
Volumetric(Act)
Yes
Yes
Yes
E23:
MultiChAccuracy
Measured
Composite
Volumetric(Act)
will hold the last
good value
Frequency value based
on the [Error Handling]
setting
Summary of Contents for Baker Hughes PanaFlow LC XMT1000
Page 1: ...Flow 910 327 Rev A Sep 2019 bhge com PanaFlow LC User s Manual ...
Page 2: ......
Page 4: ...ii no content intended for this page ...
Page 10: ...Contents viii PanaFlow LC User s Manual ...
Page 14: ...Preface xii PanaFlow LC User s Manual no content intended for this page ...
Page 142: ...Appendix E CE Mark Compliance 128 PanaFlow LC User s Manual no content intended for this page ...
Page 182: ...Warranty 168 PanaFlow LC User s Manual no content intended for this page ...
Page 189: ......