AZ6500 series ONLY
The indoor fan is turned on 3 seconds before the compressor and outdoor fan is turned ON. The outdoor fan
and the compressor are turned ON at the same time. The indoor fan is then turned OFF 6 seconds after the
compressor and outdoor fan are turned OFF.
FAN CYCLE - HEAT PUMP MODE
Fan Cycle - Heat Pump Mode
Temp. S0.9°F
Temperature
COMPRESSOR AND
OUTDOOR FAN
INDOOR FAN
ON
ON
ON
ON
6 sec
3 sec