background image

15

Safety Instructions

Operating Instructions

Care and Cleaning

Installation Instructions

Troubleshooting T

ips

Consumer Support

Air Conditioner Warranty.

For The Period Of:

GE Will Replace:

One Year

Any part 

of the air conditioner which fails due to a defect in materials or workmanship. 

From the date of the

During this 

full one-year warranty, 

GE will also provide, 

free of charge, 

all labor 

original purchase

and in-home service to replace the defective part.

Five Years

Any part of the sealed refrigerating system 

(the compressor, condenser, evaporator 

From the date of the

and all connecting tubing) which fails due to a defect in materials or workmanship.

original purchase

During this 

five-year warranty, 

GE will also provide, 

free of charge, 

all labor and 

in-home service to replace the defective part.

Service trips to your home to teach you how to use the
product.

Improper installation. If you have an installation
problem, or if the air conditioner is of improper cooling
capacity for the intended use, contact your dealer or
installer. You are responsible for providing adequate
electrical connecting facilities.

Failure of the product resulting from modifications to
the product or due to unreasonable use including
failure to provide reasonable and necessary
maintenance.

In commercial locations labor necessary to move the
unit to a location where it is accessible for service by an
individual technician.

Replacement of house fuses or resetting of circuit
breakers.

Failure due to corrosion on models not corrosion-
protected.

Damage to the product caused by improper power
supply voltage, accident, fire, floods or acts of God.

Incidental or consequential damage caused by possible
defects with this air conditioner.

What GE Will Not Cover:

This warranty is extended to the original purchaser and any succeeding owner for products purchased for
home use within the USA. In Alaska, the warranty excludes the cost of shipping or service calls to your home.

Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty
gives you specific legal rights, and you may also have other rights which vary from state to state. To know
what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.

Warrantor: General Electric Company. Louisville, KY 40225

All warranty service provided by our Factory Service Centers, 
or an authorized Customer Care

®

technician. To schedule service,

on-line, 24 hours a day, contact us at www.GEAppliances.com, or
call 800-GE-CARES.

Staple your receipt here. 

Proof of the original purchase

date is needed to obtain service

under the warranty.

Summary of Contents for AVX07

Page 1: ...dow Installation 13 Horizontal Sliding Window Installation 9 12 Preparation 8 Troubleshooting Tips 14 Normal Operating Sounds 14 Consumer Support Consumer Support Back Cover Warranty 15 AVX07 AVX08 AVX10 Owner s Manual and Installation Instructions www GEAppliances com Write the model and serial numbers here Model ________________________ Serial ________________________ Find these numbers on a lab...

Page 2: ...Installation Instructions before it is used Never unplug your air conditioner by pulling on the power cord Always grip plug firmly and pull straight out from the receptacle Repair or replace immediately all electric service cords that have become frayed or otherwise damaged Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end Turn the mode ...

Page 3: ...e Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded Where a 2 prong wall outlet is encountered it is your personal responsibility and obligation to have it replaced with a properly grounded 3 prong wall outlet The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches ...

Page 4: ... temporary connection may be made to a properly grounded 2 prong wall outlet by use of a UL listed adapter available at most local hardware stores The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord When disconnecting the power cord from the adapter always hold the adapter in place with one hand while...

Page 5: ...ing Select HI COOL or MED COOL with the temp control at 5 or 6 For Maximum Cooling Select HI COOL with the temp control at 10 For Quieter Nighttime Cooling Select LOW COOL with the temp control at 3 or 4 Temp Control The temp control is used to maintain the room temperature The compressor will cycle on and off to keep the room at the same level of comfort When you turn the knob to a higher number ...

Page 6: ...portant information Exhaust Control When set at CLOSED only the air inside the room will be circulated and conditioned When set at OPEN some inside air is exhausted outside OPEN CLOSED Air Direction The air direction tabs are located at the top on either side of the front grille The tabs let you control the air to the left right or straight ahead To adjust it up or down move the bank of louvers ...

Page 7: ...nhook the filter from the tabs Clean the filter with warm soapy water Rinse and let the filter dry before replacing it Replace the inlet grille CAUTION DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance 4 3 2 1 Outdoor Coils The coils on the outdoor side of the air conditioner should be checked regularly If they are clogged with dirt or so...

Page 8: ...ng from the power cord Do not change the plug on the power cord of this air conditioner Aluminum house wiring may present special problems consult a qualified electrician Before You Begin Some models require 115 120 volt a c 60 Hz grounded outlet protected with a 15 amp time delay fuse or circuit breaker The 3 prong grounding plug minimizes the possibility of electric shock hazard If the wall outl...

Page 9: ...ns Read these instructions completely and carefully Parts Included 1 2 3 4 5 6 7 3 9 10 TEMP MODE OFF HI COOL HI FAN LOW FAN LOW COOL MED COOL OPEN CLOSED Leveling bolt nut Window stopping clips 2 Filler panel Foam window side gasket Type A 2 Washer and nut 2 Type B 2 Type C 7 Support angle Air conditioner Sill plate Top retainer bar Adhesive back foam seal 3 Support platform ...

Page 10: ...t and nut Place the sill plate against the lower window track and firmly against the vertical side edge of the window frame Attach the sill plate to the window stool using 2 type B screws NOTE To overcome interference of the support platform with the window track or storm window securely attach a 2 wide shim strip to the window sill This strip should be as long as the width of the support platform...

Page 11: ...ges of the window frame and the sliding window that will rest against the air conditioner Cut one piece to the width of the window opening and apply to the top inside edge of the window frame Slide the air conditioner onto the support platform Be sure the side channel butts against the vertical side edge of the window frame Drill two 1 8 holes in the window channel frame through the existing holes...

Page 12: ...w Attach the top retainer bar to the top of the panel Put the filler panel into the bottom retainer attached to the air conditioner and extend the sliders upward making sure the panel stays in the tracks of the sliders Drill 1 8 holes to align with the existing holes in the sliders Secure with 2 type C screws NOTE Check all seals and plug any remaining air gaps with a suitable weatherproof caulk L...

Page 13: ... weather If you want to install the air conditioner in a window that opens you must remove the catch handle and the entire crank handle assembly Then either remove the window or fold it back against the building and fasten it securely TEMP MODE OPEN CLOSED LOW FAN HI FAN LOW COOL HI COOL MED COOL OFF 3 4 5 6 7 8 9 10 2 1 C TEMP MODE OPEN CLOSED LOW FAN HI FAN LOW COOL HI COOL MED COOL OFF 3 4 5 6 ...

Page 14: ... high enough provides maximum cooling The air filter is dirty Clean the filter at least every 30 days See the Care and cleaning of the air conditioner section The room may have been hot When the air conditioner is first turned on you need to allow time for the room to cool down Cold air is escaping Check for open furnace floor registers and cold air returns Set the air conditioner s vent to the cl...

Page 15: ...re to provide reasonable and necessary maintenance In commercial locations labor necessary to move the unit to a location where it is accessible for service by an individual technician Replacement of house fuses or resetting of circuit breakers Failure due to corrosion on models not corrosion protected Damage to the product caused by improper power supply voltage accident fire floods or acts of Go...

Page 16: ...rn about special discounts that are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your warranty expires Parts and Accessories www GEAppliances com Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes...

Reviews: