Installer: Leave these instructions
with the appliance.
•
Owner: Keep these instructions for
future use.
•
For personal safety, this air
conditioner must be properly
grounded.
•
It is important to have the wall out-
let and circuit checked by a quali-
fied electrician if there is any doubt
as to whether a proper ground
exists.
•
Follow national electrical codes or
local codes and ordinances.
CAUTION:
•
Do not, under any circumstances,
cut or remove the third (ground)
prong from the power cord.
•
Do not change the plug on the
power cord of this air conditioner.
•
Aluminum house wiring may
present special problems–
consult a qualified electrician.
Important Notes
The 230/208-volt models
require
their own single branch circuit sup-
plying 230/208-volt a.c., protected
with a time delay fuse or circuit
breaker.
This is recommended for best
performance and to prevent over-
loading house wiring circuits,
which could cause a possible fire
hazard from overheating wires.
Electrical
Requirements
Parallel
115V., 15 Amp.
Perpendicular
230/208V., 20 Amp.
Tandem
230/208V., 15 Amp.
Large Tandem
230/208V., 30 Amp.
Installation Instructions
Important Electrical Safety—Read Carefully
7