background image

14

Normal Operating Sounds

■ 

You may hear a pinging noise caused by water
being picked up and thrown against the
condenser on rainy days or when the humidity 
is high. This design feature helps remove
moisture and improve efficiency.

■ 

You may hear the thermostat click when the
compressor cycles on and off.

■ 

Water will collect in the base pan during
high humidity or on rainy days. The water
may overflow and drip from the outdoor side
of the unit.

■ 

The fan may run even when the compressor 
does not.

Troubleshooting Tips…

Troubleshooting Tips: Save time and money!

Problem

Possible Causes

What To Do

Air conditioner

The air conditioner

Make sure the air conditioner plug is pushed

does not start

is unplugged.

completely into the outlet.

The fuse is blown/circuit

Check the house fuse/circuit breaker box and replace

breaker is tripped.

the fuse or reset the breaker.

Power failure.

If power failure occurs, turn the air conditioner 

OFF

.

When power is restored, wait 3 minutes to restart the
air conditioner to prevent tripping of the compressor 
overload.

Air conditioner does

Airflow is restricted.

Make sure there are no curtains, blinds or furniture

not cool as it should

blocking the front of the air conditioner.

The temp control may

On models with touch pads: In 

COOL

mode, press the 

not be set correctly.

DECREASE

▼ 

pad. 

On models with control knobs, turn the temperature 
knob to a higher number. 

The air filter is dirty.

Clean the filter at least every 30 days.
See the 

Operating Instructions

section.

The room may have been hot.

When the air conditioner is first turned on, you need 
to allow time for the room to cool down.

Cold air is escaping.

Check for open furnace registers and cold air returns.

Set the air conditioner’s vent to the closed position.

Cooling coils have iced up.

See “

Air conditioner freezing up

” below.

Air conditioner

Ice blocks the air flow

On models with control knobs, set the mode control 

freezing up

and stops the air conditioner

at 

HIGH FAN 

or 

HIGH COOL

with the temp at 

1

or 

2

.

from cooling the room.

On models with touch pads, set the controls at 

HIGH FAN 

or 

HIGH COOL 

and set the thermostat to 

a higher temperature.

The remote control is 

The batteries are inserted

Check the position of the batteries. They should be 

not working

incorrectly.

inserted in the opposite (+) and (–) direction.

The batteries may be dead.

Replace the batteries.

Water drips outside

Hot, humid weather. 

This is normal.

Water drips indoors

The air conditioner is not

For proper water disposal, make sure the air conditioner

tilted to the outside.

slants slightly from the case front to the rear.

Water collects in 

Moisture removed from air 

This is normal for a short period in areas with little

base pan

and drains into base pan.

humidity; normal for a longer period in very humid areas.

“E1” appears

Function error code.

Unplug the air conditioner. Wait 3 minutes and plug it 

in the display

back in. 

TIMER feature not 

A power outage or interruption 

In the case of a power outage or interruption, the unit  

working properly

occurred.

TIMER

feature will reset to the original setting. You may 

need to set a new time if desired. 

Consumer Support

Tr

oubleshooting T

ips

Operating Instructions

Safety Instructions

Installation Instructions

Summary of Contents for ASF05

Page 1: ...g Tips 14 Normal Operating Sounds 14 Consumer Support Consumer Support 18 Product Registration 15 16 Warranty 17 DB98 15878A 49 7471 11 03 JR ASF05 ASL05 ASM05 ASN05 ASQ05 ASV05 ASL06 ASN06 Air Condit...

Page 2: ...federal law must be removed prior to product disposal If you are getting rid of an old product with refrigerants check with the company handling disposal about what to do SAFETY PRECAUTIONS Do not un...

Page 3: ...made to a properly grounded 2 prong wall outlet by use of a UL listed adapter available at most local hardware stores The larger slot in the adapter must be aligned with the larger slot in the wall ou...

Page 4: ...air conditioner is off it can be set to automatically turn on in 1 to 12 hours at its previous setting Each touch will set the time in hours OFF When the air conditioner is on it can be set to automa...

Page 5: ...tat at a higher number and the indoor air will become warmer NOTE If the air conditioner is off and is then turned on while set to COOL it will take approximately 3 minutes for the compressor to start...

Page 6: ...nt For Maximum Cooling Select HIGH COOL with the temp control at the highest number available on your knob For Quieter Nighttime Cooling Select LOW COOL with the temp control at midpoint Temp Controls...

Page 7: ...ntal louvers adjusts the air direction up or down OR Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions 7 www GEAppliances com Additional contro...

Page 8: ...conditioner should be checked regularly If they are clogged with dirt or soot they may be professionally steam cleaned a service available through your GE service outlet Grille and Case Turn the air...

Page 9: ...els remove the knobs filter and screw behind the filter bottom Gently but firmly grasp the lower grille corners and pull forward to release Lift the top of the grille up and off to release from the ta...

Page 10: ...nded outlet protected with a 15 amp time delay fuse or circuit breaker The 3 prong grounding plug minimizes the possibility of electric shock hazard If the wall outlet you plan to use is only a 2 pron...

Page 11: ...on Instructions PARTS INCLUDED Type A 9 Security bracket 3 Type B 8 Top mounting rail Right accordion panel Foam top window gasket Window sash seal Left accordion panel Air conditioner Top mounting ra...

Page 12: ...d without the accordion panels if needed to fit in a narrow window See the window opening dimensions All supporting parts must be secured to firm wood masonry or metal The electrical outlet must be wi...

Page 13: ...o the side of the case using 6 type A screws 3 D Top mounting rail Accordion panels Installation Instructions 4 A Window sash seal B INSTALL AIR CONDITIONER IN WINDOW CONT Extend the left and right ac...

Page 14: ...ay have been hot When the air conditioner is first turned on you need to allow time for the room to cool down Cold air is escaping Check for open furnace registers and cold air returns Set the air con...

Page 15: ...tection or you may request your money back on the remaining value of your contract No questions asked It s that simple Protect your refrigerator dishwasher washer and dryer range TV VCR and much more...

Page 16: ...r Cut here Complete and mail your Consumer Product Ownership Registration today Have the peace of mind of knowing we can contact you in the unlikely event of a safety modification After mailing the re...

Page 17: ...de reasonable and necessary maintenance In commercial locations labor necessary to move the unit to a location where it is accessible for service by an individual technician Replacement of house fuses...

Page 18: ...ded warranty and learn about special discounts that are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consum...

Page 19: ...r problemas 14 Sonidos normales de operaci n 15 Servicio al consumidor Garant a 17 Servicio al consumidor 18 DB98 15878A 49 7471 11 03 JR ASF05 ASL05 ASM05 ASN05 ASQ05 ASV05 ASL06 ASN06 Acondicionador...

Page 20: ...iene refrigerantes los que por Ley Federan deben ser removidos antes de desecharlos Si usted planea deshacerse de alg n producto que contenga refrigerantes p ngase en contacto con la compa a que se en...

Page 21: ...L disponible en la mayor a de las ferreter as La ranura mayor en el adaptador debe estar alineada con la p a mayor en la pared para proporcionar una polaridad apropiada en la conexi n del cable el ctr...

Page 22: ...te dentro de 1 a 12 horas en el nivel previo Cada toque ajustar el tiempo en horas OFF APAGADO Cuando el acondicionador de aire est encendido puede ajustarse para que se apague autom ticamente dentro...

Page 23: ...ire est apagado y luego se enciende mientras est ajustado en COOL FR O tomar aproximadamente 3 minutos para que el compresor comience a enfriar otra vez Descripciones de enfriamiento Para enfriamiento...

Page 24: ...de temperatura en el n mero mayor disponible en su teclado Para enfriamiento silencioso durante la noche Seleccione LOW COOL ENFRIAMIENTO BAJO con el control de temperatura en el nivel medio Controles...

Page 25: ...a con los dedos en las parrillas horizontales ajustar la direcci n del aire hacia arriba o hacia abajo O BIEN 7 www GEAppliances com Controles adicionales e informaci n importante Control de ventilaci...

Page 26: ...eben inspeccionar con frecuencia las bobinas en el lado exterior del acondicionador de aire Si las mismas est n obstruidas con suciedad u holl n podr an limpiarse profesionalmente con vapor En un punt...

Page 27: ...lla por la parte inferior y tire hacia adelantes para liberarla Levante la tapa de la parrilla para liberarla de las orejillas Para reemplazar la parrilla Enganche el frente de la parrilla en las orej...

Page 28: ...15 amperios o un cortacircuitos El enchufe de tres p as con conexi n a tierra minimiza la posibilidad de descargas el ctricas Si el tomacorriente de la pared que usted planea usar solamente tiene 2 t...

Page 29: ...Soporte de seguridad 3 Tipo B 8 Riel de montaje superior Panel de acorde n derecho Parte superior de la espuma de la junta de la ventana Banda de sello de la ventana Panel de acorde n izquierdo Acondi...

Page 30: ...opiadamente Para solucionar este problema adhiera un pedazo de madera a la repisa PIEZAS DE MADERA ANCHO 2 LONGITUD Suficiente longitud para ajustarse al interior del marco de la ventana ESPESOR Para...

Page 31: ...o los 6 tornillos tipo A 3 D Riel de montaje superior Paneles de acorde n Instrucciones para la instalaci n 4 A Sello de la banda de ventana B INSTALE EL ACONDICIONADOR DE AIRE EN LA VENTANA CONT Exti...

Page 32: ...bobinas de enfriamiento Ver Acondicionador de aire congel ndose m s adelante se congelaron El acondicionador de aire El hielo bloquea el flujo En modelos con los botones de control coloque el modo se...

Page 33: ...sos o cuando la humedad es alta Esta caracter stica de dise o ayuda a remover la humedad y mejora la eficiencia Quiz s escuche que el termostato hace clic cuando el compresor hace ciclo entre encendid...

Page 34: ...16 Servicio al consumidor Solucionar problemas Operaci n Seguridad Instalaci n Notas...

Page 35: ...y necesario En locales comerciales la mano de obra necesaria para retirar la unidad hacia un lugar para revisi n por parte de un t cnico individual Reemplazo de fusibles de la casa o reajuste del sist...

Page 36: ...nga detalles sobre descuentos especiales disponibles mientras su garant a est a n activa Puede comprarla en l nea en cualquier momento o llamar al 800 626 2224 durante horas normales de oficina GE Con...

Reviews: