GE Arize Element Series Installation Manual Download Page 4

4

 

CAUTION / ATTENTION

Always wear safety gloves while handling light modules.

Portez toujours des gants de protection lorsque vous manip-

ulez les luminaires.

Installation

1

Install the support cables 
A)
 At first end of light module, wrap non carabiner 

end of support cable around structural member.
B) Pass carabiner through support cable loop to 

create a noose. 
Repeat with second support cable at other end of 

light module.

Structural member

A

A

B

B

2

Install the light module 
A)
 Attach first carabiner to the 1/4’’ round hole 

on one side of the light module. Repeat on 

other side of light module.
B) Ensure both carabiners are through the hole 

and both gates are closed.

Hanging the Light Module

NOTE: Ensure greenhouse structures and members are rated for loads created by light modules and drivers. 

Suitable min. 2 mm diameter suspension cable required to complete installation. 

4

3

Rotate driver so that the brackets can engage 

with the structural member. Lower driver into 

position.

Lift driver so that the structural member is 

between the brackets.

NOTE: The base driver mounting kit is for a 1 5/8’’ square structural member. For other structural 

members, see accessories or contact your account manager.

Hanging the Driver

Driver output

Summary of Contents for Arize Element Series

Page 1: ...es locaux applicables Ce produit doit être installé selon le code d installation pertinent par une personne qui connaît bien le produit et son fonctionnement ainsi que les risques inhérents L installation et les structures associées sont soumises à l approbation des autorités compétentes Utilisez uniquement avec les composants identifiés dans ce document Convient aux endroits secs humides et mouil...

Page 2: ... HPKR4 2NX1 Top light 4 ft pink reproductive 646W 120 208 240 277 5 4 3 1 2 6 2 3 0 9 GEHTL HPKB4 2NX1 Top light 4 ft pink balanced 646W 120 208 240 277 5 4 3 1 2 6 2 3 0 9 GEHTL HPKF4 2NX1 Top light 4 ft pink flower 646W 120 208 240 277 5 4 3 1 2 6 2 3 0 9 GEHTL HWTN4 2NX1 Top light 4 ft white industrial 646W 120 208 240 277 5 4 3 1 2 6 2 3 0 9 GEHTL MPKR4 2NX1 Top light 4 ft pink reproductive 34...

Page 3: ...ipe member bracket 2 X 1 3 8 pipe bracket 95047411 GEHAK NN NE N0 Driver universal 1 remote mount kit 2 X 1ft driver support cable 95047654 GEHAK NN NN J1 Wire dimming junction box kit Junction box 2 cable glands 95047660 GEHAK NN NN D1 UL wall mounted dimming switch Dimming switch Accessories ATTENTION ATTENTION Installation instructions and specifications for accessories can be found in the acce...

Page 4: ...und hole on one side of the light module Repeat on other side of light module B Ensure both carabiners are through the hole and both gates are closed Hanging the Light Module NOTE Ensure greenhouse structures and members are rated for loads created by light modules and drivers Suitable min 2 mm diameter suspension cable required to complete installation 4 3 Rotate driver so that the brackets can e...

Page 5: ... water tight seal and good connection Driver Output Electrical Connections Male Light module Secure locknut Driver Female Connection Schematic WARNING AVERTISSEMENT Ambient temperature surrounding each driver must be lower than 113 F 45 C La température ambiante autour de chaque module d alimentation ne doit pas excéder 113 F 45 C Driver Input Wire Colors Black Line 1 White Neutral or Line 2 Yello...

Page 6: ...sure NOTE Be sure to hold on to the screws junction box cover and gasket for future use Wall Dimming Wire Insertion Remove the sealed gland in the top of the junction box enclosure and install an appropriate Listed NPT fitting rated for the environment into the open threaded open conduit connection Bring the conductors for the building dimming network into this fitting NOTE Customer is responsible...

Page 7: ...rticultural luminaires and their placement and or positioning within the plant growth facility It is the responsibility of the plant growth facility to address these risks at the facility level and to ensure that people entering the plant growth areas while the lights are on are aware of these risks and that appropriate safeguards are in place Ces avertissements de sécurité photobiologiques sont b...