background image

Care and 

USER 

Turn air conditioner off and
remove the plug from the wall
outlet before cleaning.

Grille & Cabinet

Wipe both sides of grille with a
clean cloth lightly dampened with
mild liquid 

 detergent,

or clean with a vacuum cleaner
brush. Be careful not to force the
movable louvers out of position.

Other areas behind the grille may
be wiped or vacuumed, taking care
not to damage the coil fins.

Wash cabinet with mild soap or
detergent and lukewarm water.
Never use strong chemicals,

 or bleaching agents.

Condenser Coils

These coils on the weather side
of the unit should be checked
periodically and cleaned if 
with dirt or soot from the atmosphere.
If extremely soiled, they may 
to be steam cleaned, a service 
through your 

 Electric service

outlet.

Air Filter

The air filter behind the front grille
should be checked and cleaned at
least every 30 days or as often as it
needs cleaning.

To 

remove the filter:

Grasp the tab at the bottom left side
of the unit and pull downward.

Clean the filter with a vacuum
cleaner to remove light dust. Wash
the filter in lukewarm, soapy water
and rinse in clear water to remove

sticky dust.

When replacing the filter, be sure
the word FRONT is facing you as
you slide the filter back into place.

Front Grille Removal

If your air conditioner is mounted
flush inside the room or if the
window sill extends further into the
room than the chassis, it may be
necessary to remove the front grille
before the filter can be removed.

To remove the grille:

1. Grasp the bottom of the grille

and swing it toward you about 30
degrees.

2. Slide the grille upward to free
the three tabs at the top of the grille

from slots in the top of the cabinet.

The air filter can now be removed
from the grille—grasp the tab on
the filter and pull.

After cleaning, replace the air filter
and grille, hooking top of grille
onto top of cabinet and pushing
bottom of grille in until it snaps
into place.

6

Summary of Contents for APS12

Page 1: ...RS18 Control Settings 4 5 Electrical Requirements 3 Energy Saver Switch 4 Energy Saving Tips 2 Extension Cords 3 Grille and Cabinet 6 Grounding 3 Model and Serial Numbers 2 Problem Solver 7 Repair Service 7 Safety Instructions 2 User Maintenance Instructions 6 Warranty Back Cover Your Direct Line to Geneml Electric The GE Amwer Centef 800 626 2000 GENERAL ELECTRIC ...

Page 2: ...ructions before it is used See grounding instructions on page 3 Never unplug your air conditioner by pdiing on the power cord Always grip plug firndy and pull straight out from the outlet Repair or replace hnmediately all elwtric service cords that have become frayed or otherwise damaged Do not use a cord that shows cracks or abrasion damage along ih length or at either the plug or connector end S...

Page 3: ...CTION Whether your air conditioner is a f15 volt or a 230 208 volt unit it is important to have the wall outlet and circuit checked by a qualified electrician if there is any doubt as to whether a proper ground exists Use of adapter plug volt modek only Because of potential safety hazards under certain conditions we strongly recommend against use of an adapter plug However if you still elect to us...

Page 4: ... HIGH COOL permits cooling with high fan speed operation LOW HEAT permits heating with low fan speed operation D HEAT permits heating with medium fan speed operation HIGH HEAT permits heating with high fan speed operation THERMOSTAT Thermo t When you turn this control to the desired setting the thermostat will automatically control the temperature of the indoor air The higher the number selected t...

Page 5: ...st be in NOMAL position For Ventilation Whether controls are set for cookg heating or fa ody operation setting VENTILATION control at OPEN lets room air be exhausted to the outside This is helpful in removing stale air smoke or odors from the room and permits outdoor air to enter through norrnd openings in the house However cooling effectiveness is reduced when this control is set at OPEN so we su...

Page 6: ...nd cleaned at least every 30 days or as often as it needs cleaning To remove the filter Grasp the tab at the bottom left side of the unit and pull downward Clean the filter with a vacuum cleaner to remove light dust Wash the filter in lukewarm soapy water and rinse in clear water to remove sticky dust When replacing the filter be sure the word FRONT is facing you as you slide the filter back into ...

Page 7: ...ff with compressor when Selector is in cool or heat position and ENER SAVER switch is at SAVE Otherwise f runs continuously when air conditioners on Excess wa r may overflow in ext me y hot and humid weather This is normal Air conditioner must be instiled level or tilted slightly to the outside for proper water disposaI If you need more help call toll free The GE Answer Center 800 626 2000 consume...

Page 8: ...ERVICE WHAT IS N COVERED Service trips to teach you how to use the product Read your Use and Care material If you then have any questions about operating the product please contact your dealer or our Consumer Affairs office at the address below or call toll free The GE Answer Cente 800 626 2000 consumer information service Improper installation If you have an installation problem or if the air con...