FOR SERVICE TECHNICIAN ONLY—DO NOT REMOVE OR DESTROY

175D6149P002

DETAILS FUNCTION

Requirement

Sequence

t01

none

Start

Displays defined Model id (1-6); displays “---” if new board (to set Model id, rotate knob until desired id (1-6) 

displayed, press and hold “START” key to program this model)

Power

Returns to “t01”

t02

none

Start

Displays most recent error code (E00=none)

Start

Displays previous error code (up to previous 10)

Hold start

Clear all error codes (and then displays E00)

Power

Returns to “t02”

t03

none

Start

Alternate “UL” and UL software version

Start

Alternate “cod” and Control Software version

Start

Alternate “EE” and eePROM version

Start

Alternate “Inv” and Inverter Software version

Power

Returns to “t03”

t04

none

Start

Loops on lighting LED’s, LCD, and cycle ids

Any button

Beeps when depressed

Power

Returns to “t04”

t05

none

Start

Displays “P” and pump for 60 seconds

Power

Returns to “t05”

t06

none

Start

Displays “E” (for Empty) and starts filling when reaches Foam level—displays “F”

Start

Fill, when reaches Main level—displays “nl”

Start

Fill, when reaches overflow level—briefly displays “OF,” pumps out, displays “E” when tub empty

Power

Returns to “t06”

t07

Main level 

pressure 

switch must 

work

Start

For GFWH1100, GFWN1200, GFWN1300, GMAN1200 models: 

Displays temperature in °F, turns on cold water (CV1) for 10 seconds, turns off CV1 and turns on HV for a maximum

pressure time-out of 5 minutes

For GFWH1200, GFWH1300, GFWH1400, GFWH1405, GFWS1500, GFWS1505 models: 

Displays temperature in °F, turns on the CV and fills the tub until the Main level switch closes. Turn on the heater for a 

maximum of 5 minutes

Power

Pumps out water and returns to “t07”

t08

none

Start

Displays “SEA” and rotates the basket at 43 revolutions per minute (only for GFWS1500 and GFWS1505 models

Power

Stops rotating the basket, turns off the steam and returns to “t08”

t10

none

Start

Displays “tt” and tumbles tub alternating the direction every 5 seconds

Power

Stops tumbling and returns to “t10”

t11

none

Start

Spins to 400 RPM displaying increasing RPM

Start

For GFWH1100, GFWN1200, GFWN1300, GMAN1200, GFWH1200, GFWH1300 models: 

Spins to 1000 RPM (displays A00)

For GFWH1400, GFWH1405, GFWS1500, GFWS1505 models: 

Spins to 1100 RPM (displays B00)

Power

Stops spinning and returns to “t11” when stops

t12

none

Start

Displays “ddt” and turns on HV to fill detergent compartment (for GFWH1100, GFWN1200, GFWN1300, GMAN1200, 

GFWH1200, GFWH1300 models)

Displays “pdt” and turns on HV to fill Pre Wash compartment (for GFWH1400, GFWH1405, GFWS1500, GFWS1505 models)

Start

Displays “bdt” and turns on CV2 to fill bleach compartment (for GFWH1100, GFWN1200, GFWN1300, GMAN1200, GFWH1200, 

GFWH1300 models)

Displays “ddt” and turns on HV to fill main dispensing compartment (for GFWH1400, GFWH1405, GFWS1500, GFWS1505 

models)

Start

Displays “Fdt” and turns on CV1 and CV2 to fill softener compartment (for GFWH1100, GFWN1200, GFWN1300, GMAN1200, 

GFWH1200, GFWH1300 models)

Displays “bdt” and turns on CV to fill bleach compartment (for GFWH1400, GFWH1405, GFWS1500, GFWS1505 models)

Start

Displays “HCt” and turns on CV1 and HV to fill detergent compartment (for GFWH1100, GFWN1200, GFWN1300, GMAN1200 

GFWH1200, GFWH1300 models)

Displays “Fdt” and turns on CV to fill softener compartment (for GFWH1400, GFWH1405, GFWS1500, GFWS1505 models)

Power

Pumps out water and returns to “t12”

t13

none

Start

Starts EOL test sequence (NOT used in Repair)

Power

Returns to “t13”

6

Summary of Contents for Appliances GMAN1200

Page 1: ...sed into connections far enough The most common cause for control failure is corrosion on connectors Therefore disconnecting and reconnecting wires will be necessary throughout test procedures Connect...

Page 2: ...2 FOR SERVICE TECHNICIAN ONLY DO NOT REMOVE OR DESTROY 175D6149P002 WIRE DRAWING for models GFWN1100 GFWN 1200 GFWN1300 and GMAN1200 WIRE DRAWING for models GFWH1400 and GFWH1405...

Page 3: ...3 FOR SERVICE TECHNICIAN ONLY DO NOT REMOVE OR DESTROY 175D6149P002 WIRE DRAWING for models GFWH1200 and GFWH1300 WIRE DRAWING for models GFWS1500 and GFWS1505...

Page 4: ...4 FOR SERVICE TECHNICIAN ONLY DO NOT REMOVE OR DESTROY 175D6149P002 SYSTEM DRAWING...

Page 5: ...at all the displays and buttons work t05 Pump Test Test drain out pump t06 Pressure Switch Test Fills to all 3 levels then pumps out water t07 Thermistor Heater Test Verifies that both the Thermistor...

Page 6: ...um of 5 minutes Power Pumps out water and returns to t07 t08 none Start Displays SEA and rotates the basket at 43 revolutions per minute only for GFWS1500 and GFWS1505 models Power Stops rotating the...

Page 7: ...sure AC outlet voltage ensure correct range 102V to 132V AC 4B 4C internal Check electrical connections at the drum motor motor drive 50 52 problems Check harness integrity between main control and mo...

Page 8: ...OR SERVICE TECHNICIAN ONLY DO NOT REMOVE OR DESTROY MODEL NUMBERS GFWN1100 GFWN1200 GFWH1200 GMAN1200 GFWN1300 GFWH1300 GFWH1400 GFWH1405 GFWS1500 GFWS1505 31 16849 04 12 GE Printed in China 175D6149P...

Reviews: