background image

Summary of Contents for Appliances AS706

Page 1: ... 6 Installation Imtructions Preparing to Install the Air Conditioner 7 Through the Wall Installation Optional 12 Window Installation 8 11 Troubleshooting Tips 13 Nolrnal Operating Sounds 13 ConsumerSupport Consumer Support Back Cover Product Registration 17 18 Wananty 19 ASP05 ASV05 AST05 AS706 Write the modeland serial numbershere Find these numbers on a label on the side of the air conditioner 4...

Page 2: ...ot store or use combustible mamrials gasoline or other flammable vapors or liquids in the vidnity of this or any other appliance HOWTOCONNECT ELECTRICITY Do not under any circumstances cut or remove the third ground prong from the power cord For personal safety this appliance must be properly grounded The power cord of this appliance is equipped with a 3 prong grounding plugwhich mates with a stan...

Page 3: ... properly gq ounded 2 prong wall outlet by use of a UL listed adapter available at most local hardware stores The lalger slot in the adapter must be aligned with tile larger slot in tile wall outlet m provide proper polarity in the connection of tile power cord When disconnecting tile power cord fl om the adapter always hold the adapter in place with one hand while pulling the power cord plug with...

Page 4: ...ng NOTE If youmovetheswitchfromacoolsettingto OFF orto a fansetting waitat least3 minutes beforeswitching backto acoolsetting Cooling Descriptions ForNormal Cooling Select HIGHCOOL or MED COOL with the temp control at midpoint ForMaximum Cooling Select HIGH COOL with the temp control at the highest number available on your knob ForQuieter Nighttime Cooling Select LOWCOOL with the temp control at m...

Page 5: ...ated and conditioned When _t at OPEN some inside air isexhattsted outside r TO open the vent push the lever to the right TO close it push it to the left Air Direction Side to Side On some models the side lo side air direction is adjusted by Ille louver levers or by gPasping and moving the inner vertical louvers OR Air Direction Up and Down on some models Fingertip pressure on the hork _ ntal louve...

Page 6: ...irFilter The air filter behind the front _ille should be checked and cleaned at least every 30 lays o1 more often if necessaly Clean Ihe filter with walrn soapy water Rinse and let the filter dry before replacing it CAUTION DONOToperate theairconditioner without a filterbecause dirt andlint will clogit andreduce performance TO remove onsomemodels pen the inlet grille upward by pulling out the bott...

Page 7: ...ower cord of this air conditioner Aluminum house wiring may present special problems consult a qualified electrician Electrical Requirements _ me models require 115 120 voh a c 60 Hz grounded outlet protected with a 15 amp time delay lla_ or circuit breaker The 3 prong grounding plug minimizes 1he lX ssibility of electric shock hazard If the wall outlet you plan m use is only a 2 prong outlet it i...

Page 8: ...ndowInstallationInstructions Parts Included Top mounting rail Air conditioner Window seal w 22a T P me _s_inpg rail gasKez_ Left accordion panel Right accordion panel TypeA 9 Type B 8 Security bracket 3 8 ...

Page 9: ...e within reach of the Ix wet cord I I IB 4 12W rain 22 to 36 Withaccordion panels I I 1T_6 min Withoutaccordion panels Storm Window Requirements A storm window frame will not allow flae air conditioner m tilt rewards the outside and will keep it from draining properly To adjttst for this attach a piece of wood to the stool Wood 1 2 higher I 1 WOODPIECES WIDTH 2 LENGTH Ixmg enough to fit inside the...

Page 10: ...ty bracket on each side Tighten the screws to secure the brackefs in place Install 1he top mounting rail with 3 lype A screws fl om the outside of flle case Top mounting rail _ _ _ Bottom mounting rail Security bracket Security bracket Inserl the fl ames of the accordion panels into the top and bottom mounting rails Attach the accordion panels to the side of the case ttsing 6 type A screws Top mou...

Page 11: ...ts back edge Center it and close the window securely behind the top mounting rail It should be level or slightly tilted to the outside Use a level about a 1 3 bubble will be the correct case slant to the outside TypeB SCreWS Type B screw screws Attach the brackets to the stool on both sides using two 1ype B screws Install the Security Bracket and the Foam Top Window Gasket A tlach a security brack...

Page 12: ...on refer to the Window InstallationInstructions Make certain a walt receptacle is available close to the hole location or make arrangements to install a receptacle Place the case in the wall opening and secure with 12 1 long 10 wood screws NOTE Drill pilot holes if necessary for proper installation If the frame is oversized use shims to prevent case distortion Finish the Wall Open g Caulk all four...

Page 13: ... for pen furnace floor registei_ and cold air retui_qs Set the air conditioner s vent to the closed position Cooling coils have iced up See A conditioner freezing up below Ice blocks the air flow Set the mode control at HIGHFANor HIGHCOOL with and stops the air conditioner the temp at torZ from cooling the room Excessively hot and This is normal humid weather The air conditioner is not Forproperwa...

Page 14: ...m Notes m m m h m i_ _ m 14 ...

Page 15: ...Notes e _h z_ e q 15 ...

Page 16: ...m Notes m m m h m i_ _ m 16 ...

Page 17: ...remaining value of your contract No questions asked It s that simple Protect your reffigeralor dishwasher washer and dlyer range _ VCR and much more any brand Plus there s no extra charge for emergency service and low monthly financing is available Even icemaker coverage and food spoilage protection is offered You can rest easy knowing that all your valuable household products are protected agains...

Page 18: ...te yollr new appliance properly Model Number Serial Number IIIIIIIIIII IIIIIII Important If you did not get a registration card with your product detach and return the form below to ensure that your product is registered or register online at www GEAppliances com _ _ _ ut here Consumer Product Ownership Registration Model Number Serial Number I I I I I I I I I I I I I I I I I M_ _ Ms D M_s D MissD...

Page 19: ...installer You are responsible for providing adequate electrical connecting facilities _ Failure of the product resulting from modifications to the product or due to unreasonable use including failure to provide reasonable and necessary maintenance _ In commercial locations labor necessary to move the unit to a location where it is accessible for service by an individual technician _ Replacement of...

Page 20: ...ecml d_scounts that m e avadable while yore wmTanty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business horns GE Consumer Home Serv ces _ allsull be there afmr your warranty expu es PartsandAccessories w_ GEAppliances com Individuals qualified to _iwice their own appliances can have parts or accessories sent directly Io their homes VISA MasterCard and...

Reviews: