background image

 Your 

 

 Only 

Selector 

Thermostat Control

LOW

HI

OFF

OFF turns air conditioner off.

HIGH permits high fan speed
operation without cooling.

LOW permits low fan speed
operation without cooling.

LOW COOL permits cooling with
low fan speed operation.

HIGH COOL permits cooling
with high fan speed operation.

Heat/Cool 

Selector 

OFF

HE

HEAT permits heating with low
fan speed operation.

FAN permits high fan speed
operation without cooling.

OFF turns air conditioner off.

LOW COOL permits cooling with
low fan speed operation.

HIGH COOL  permits cooling
with high fan speed operation.

When you turn this control to
the desired setting, the thermostat
will automatically control the
temperature of the indoor air.
The higher the number selected,

the cooler the indoor air will be.

To test the air conditioner in cold
weather,  
turn the Thermostat
Control to TEST RUN. Return
control to desired setting when test
is completed. Note: Do not leave
Thermostat Control at TEST RUN
position any longer than necessary.

Thermostat Control

When you turn this control to
the desired setting, the thermostat

will automatically control the

temperature of the indoor air.
The higher the number selected,
the cooler the indoor air will be.

4

Summary of Contents for ANS18

Page 1: ...aning 6 Condenser oils 6 C ontrol Settings 4 5 Electrical Requirements 3 Energy Saving Tips 2 Extension Cords 3 lrille and abinet 6 irounding 3 Model and Serial Numbers 2 Problem Solver 7 Safety Instructions 2 User Maintenance Instructions 6 Cooling Only Models ANS18 ANS24 Heat Cool Models S18 S24 GEAppiances ...

Page 2: ...onnector end Ene y savi tips Keep the air filter clean See instructions on page 6 For most efficient operation keep vent in closed position except when you want to exhaust air smoke or odors from the room Don t let the room get too hot or too cold Whenever possible turn the unit on before the room heats up or cools down Keep windows and doors closed Conditioned air escapes when they re open Keep f...

Page 3: ...ecked by a qualified electrician if there is any doubt as to whether a proper ground exists Use a single branch circuit protectd with a time delay fuse or circuit breaker s is recommended for best performance and to prevent overloading house wiring circuits which could cause a possible fire h ard from overheating wires For branch circuit ratings refer to the unit nameplate 3 ...

Page 4: ...its cooling with low fan speed operation HIGH COOL permits cooling with high fan speed operation When you turn this control to the desired setting the thermostat will automatically control the temperature of the indoor air The higher the number selected the cooler the indoor air will be To test the air conditioner in cold weather turn the Thermostat Control to TEST RUN Return control to desired se...

Page 5: ...ector Switch to fan setting For ventilation Whether controls are set for cooling heating on heat cool models or fan only operation setting the Ventilation Control at OPEN lets room air be exhausted to the outside This is helpful in removing stale air smoke or odors from the room and permits outdoor air to enter through normal openings in the house However cooling effectiveness is reduced when this...

Page 6: ...at least every 30 days or as often as it Grasp the tab at the bottom left side of the unit and pull downward Clean the filter with a vacuum cleaner to remove light dust Wash the filter in lukewarm soapy water and rinse in clear water to remove sticky dust When replacing the filter be sure the word FRONT is facing you as you slide the filter back into place Wont GrWe Removal If your air conditioner...

Page 7: ...ast every 30 days See instructions on page 6 c Room may have been very hot when air conditioner was first turned on Allow time for it to cool down Q Cold air maybe escaping through open furnace floor registers and cold air returns Ventilation control maybe set at OPEN allowing hot outside air to enter room Thermostat click a metilic sound maybe heard when compressor cycles on and off This is norma...

Page 8: ...General Electric Company hUiSVii e KY40225 a is a registered trademark of eneral k lect ric ompany U S A I Pub No 49 7204 I I I 12 88 ANS18 ARS18 ANS24 ARS24 Printed In Japan ...