Electrical 

 Read 

How 

to connect

electricity

For personal safety,
this appliance must be
properly grounded.

Electrical requirement

115-volt models  require a 

volt a.c., 60   grounded outlet
protected with a 15 amp time delay
fuse or circuit breaker.

The 

power 

cord on these models has

a three-prong (grounding) plug that
mates with a standard three-prong
(grounding) wall outlet (Fig. 1) to
minimize the possibility of electric
shock hazard from these appliances.

PREFERRED
METHOD

INSURE PROPER

n- 

 

 

 I 

Fig. 1 ‘

BEFORE USE

Where a standard two-prong wall
outlet   encountered, it is your
personal responsibility and obligation
to have it replaced with a properly
grounded three-prong wall outlet.

DO 

 UNDER ANY

CIRCUMSTANCES, CUT
OR 

 THE THIRD

(GROUND) PRONG 

THE POWER CORD.

230/208-volt models  require their
own single branch circuit supplying
230/208-volt a.c., protected with a
time delay fuse or circuit breaker.
This is recommended for best

performance and to prevent
overloading house wiring circuits,
which could cause a possible fire
hazard from overheating wires.

The power cord on these models
has a 230/208-volt perpendicular,
tandem or large tandem type plug
that mates respectively with a

230/208-volt perpendicular,
tandem or large tandem type wall
outlet. These types of outlets are
available at most hardware stores.

230/208-VOLT

MATCHING

PERPENDICULAR TYPE WALL OUTLET

LINE CORD PLUG

REQUIRES 20 AMP TIME DELAY FUSE

OR CIRCUIT BREAKER PROTECTION

MATCHING

TANDEM TYPE

WALL OUTLET

LINE CORD PLUG

REQUIRES 15 AMP TIME DELAY FUSE

OR CIRCUIT BREAKER PROTECTION

230/208-VOLT

MATCHING

LARGE TANDEM TYPE

WALL OUTLET

LINE CORD PLUG

REQUIRES 30 AMP TIME DELAY FUSE

OR CIRCUIT BREAKER PROTECTION

Whether your air conditioner is a

115-volt or a 230/208-volt unit, it

is important to have the wall
outlet and circuit checked by a
qualified electrician if there is
any doubt as to whether a proper
ground exists.

Use of adapter plug

 

 only)

Because of potential safety hazards
under certain conditions, we

strongly recommend against use
of an adapter plug. 
However,

if you still elect to use an adapter,
where local codes permit, 

TEMPORARY 

may be made to a properly grounded

two-prong wall outlet by use of a

 listed adapter (Fig. 2) available

at most local hardware stores.

I

TEMPORARY METHOD

 

IADAPTER PLUGS NOT

ALIGN LARGE

PRONGS/SLOTS

‘\

     

 

     

/’

INSURE PROPER

 AND

FIRM CONNECTION

Fig. 2

BEFORE USE

The 

 slot in the 

 must be

 the larger 

 in the wall

outlet to provide proper polarity in
the connection of the power cord.

CAUTION: Attaching the adapter
ground terminal to wall outlet cover
screw does not ground the appliance
unless cover screw is metal, and not
insulated, and wall outlet is grounded
through house wiring. You should
have the circuit checked by a qualified
electrician to make sure the outlet

is properly grounded.

When disconnecting the power cord
from the adapter, 
always hold the
adapter with one hand. If this is not
done, the adapter ground terminal is
very likely to break with repeated use.

Should the adapter ground
terminal break, DO 

 USE the

appliance until a proper ground
has again been established.

Use of 

 cords

Because of potential safety
hazards under certain conditions,
we strongly recommend against the
use of an extension cord. 
However,
if you still elect to use an extension
cord, it is absolutely necessary that
it be a 

 listed 3-wire grounding

type appliance extension cord and
that the current carrying rating of
the cord in amperes be equal to or
greater than the branch circuit size

shown on the rating nameplate of
the appliance.

3

Summary of Contents for AMS06

Page 1: ...Appliance Registration 2 Repair Service 7 Care and Cleaning 6 Safety Instructions 2 Condenser Coils 6 User Maintenance Instructions 6 Control Settings 4 5 Warranty Back Cover Electrical Requirements 3 Energy Saver Switch 4 Energy Saving Tips 2 Extension Cords 3 GEAmww MeP Grille and Cabinet 6 800 6262000 Model NS06 GEAppBances ...

Page 2: ...purpose as described in this Use and Care Book This air conditioner must be properly instiled in accordance with the Installation Instructions before it is used See grounding instructions on page 3 Never unplug your airconditiomr by pulling on the power cord Always grip plug fidy and pull straight out from the receptacle Repair or replace immediately all electric service cords that have become fra...

Page 3: ...TION Whether your air conditioner is a 115 volt or a 230 208 volt unit it is important to have the wall outlet and circuit checked by a qualified electrician if there is any doubt as to whether a proper ground exists Use of adapter plug U5 volt modek only Because of potential safety hazards under certain conditions we strongly recommend against use of an adapter plug However if you still elect to ...

Page 4: ... peration HIGH COOL permits cooling with high fan speed operation L ENERGY SAVER NORMAL B SAVE The Energy Saver Switch controls the fan oDeration When it s in the NO AL position the fan will circulate room air continuously When it s in the SAVE position the fan will automatically cycle on and off with the compressor Room air temperature may fluctuate more widely when the Energy Saver Switch is in ...

Page 5: ...may freeze on the coils and prevent the unit from cooling If this happens set the Fan at high speed and set the Thermostat Control to a lower number 3 Set the Ventilation Control at CLOSE 4 Set the Energy Saver Switch at the NORMAL position Note When the Energy Saver Switch is at the SAVE position changes in the sound level may be more noticeable than when it s at the NORMAL position For ni ttime ...

Page 6: ...grille The grille is attached on front of the cabinet by four tabs and a screw Step 1 Set the air direction louvers upward Step 2 Grasp the grille s upper right and left corner and carefully insert the VENT knob between the lower air direction louver and the grille frame and engage two tabs on the grille s top inside edge with two slots in the cabinet front edge Grille Frame FRONT VIEW SIDE VIEW S...

Page 7: ...itch is in Cool or Fan position This is normal When Energy Saver Switch is set at SAVE fan cycles on and off with compressor WATER DWPPING Excess water may overflow in extremely hot and humid weather This is normal OUTSIDE WATER DRIPPING Air conditioner must be installed level or tilted slightly to the outside for proper INSIDE water disposal WATER IN BASE PAN This is normal for a short period in ...

Page 8: ...CUSTOMER CARE SERVICE WHAT IS N COVERED c Service trips to teach you how to use the product Read your Use and Care material If you then have any questions about operating the product please contact your dealer or our Consumer Affairs office at the address below or call toll free GE Answer Cente 800 626 2000 consumer information service Improper installation If you have an installation problem or i...

Reviews: