Appendix B: Reference Tables
34
Check marks (
√
) represent characteristics present in a group.
*
This group is not certified as a primary protection circuit for UL-listed systems and is for supplementary use only.
† Sounds instant police siren if two or more sensors are tripped within 4 minutes. Otherwise sensors are followers to
delayed
sensors. If Alarm Verification is on, group 18 functions like group 17.
‡ This group has not been investigated by UL.
a
The DTIM will report in all levels.
Siren Type:
Police - A high level steady siren.
Fire - A high level temporal siren.
Silent -No siren.
Emergency - A low level on-off patterned siren.
Delay:
Instant -A sensor of this type will cause an immediate alarm if a violation occurs anytime in an active arming level.
Standard - A sensor of this type will cause an entry delay if a violation occurs anytime in active arming level. A violation
during an exit delay will not cause an alarm.
If the arming level modifier No Delay is enabled a sensor of this type will cause an immediate alarm if the violation occurs
during an active arming level.
Follower - A sensor of this type will cause an immediate alarm if a violation occurs during an active level unless an entry
or exit delay is in progress. If violated during an entry delay and the entry delay expires the sensor will go into alarm.
Table B7: Sensor Group Characteristics (Continued)
No.
Name
Application
Alarm
Delay
Re
s
tora
l
Supe
rv
iso
ry
CS Re
port
Chim
e
Active
Levels
Table B8: System Settings
Menu Name
Default
Parameters
Settings
Account
00-000
4-10 digits; 0-9, A-F
Number 1
none
24 digits; 0-9, *, #, pause
FMT - CID/SIA
CID
On=CID, Off=SIA
High LVL
On
off, on
Low LVL
On
off, on
Openings
Off
off, on
Closings
Off
off, on
Number 2
none
24 digits; 0-9, *, #, pause
FMT - CID
CID
On=CID, Off=SIA
High LVL
Off
off, on
Low LVL
Off
off, on
Openings
Off
off, on
Closings
Off
off, on
Backup
On
off, on
Dial DLY
30
15-120
Pre-dial String
none
8 digits; 0-9, *, #, pause
DTMF Dial
On
off, on
Number
none
24 digits; 0-9, *, #, pause
DL Code
12345
5 digit code, 0-9
Install Code
4321
4 digit code, 0-9
Dealer Code
none
4 digit code, 0-9
Duress Code
none
4 digit code, 0-9
Manager Code
none
4 digit code, 0-9