REMOVE AIR CONDITIONER FROM CASE

  

Remove the front grille. See the Care and Cleaning 

section.

  Find the locking plate located on the front 

left side.

  Remove the screw and the locking plate to unlock 

the air conditioner.

   Remove and discard the shipping screw  

on the back of the air conditioner to allow 

removal of the air conditioner from the case.

  Pull the bottom corners of the air conditioner  

and slide it out of the case.

  Remove all shipping pads (if present) inside the air 

conditioner next to the compressor.

   Remove the rear grille that is taped to the back  

of the case. Remove the packet of screws taped  

to the back of the grille. While holding the grille at a  

45° angle, insert it into the clips at the top of the case  

and push the bottom in. Keep slight upward pressure 

on the grille until it fits flush with the bottom of the 

case.

  

17

 

 STORM WINDOW REQUIREMENTS

A storm window frame will not allow the air 

conditioner to tilt towards the outside and will keep  

it from draining properly. To adjust for this, attach  

a piece of wood to the stool.

WOOD PIECES
WIDTH:

 

 2

LENGTH:

 

Long enough to fit inside the window frame.

THICKNESS

:

 

To determine the thickness, place a piece 

of wood on the stool to make it 1/2

 higher than the top 

of the storm window frame.
Attach securely with nails or screws provided by  

the installer.

2

1/2

 higher

than frame

Storm 

window 

frame

Stool

Sill

Wood

3

A

B

C

Locking 

plate

Remove 

screw

D

Remove 

screw

E

F

   If attaching the grille  

from the outside of the 

case, use the 2 long screws.

If attaching the grille  

from the inside of the case, 

use the 2 short screws. 

G

Clips

Insert the 2 long screws  

on the outside

Insert the 2 short screws  

on the inside

Installation Instructions

Remove shipping pads 

(if present)

Summary of Contents for AJCM08ACD

Page 1: ...ling a J Model in an Existing Wall Case 14 Through the Wall Installation 15 Window Installation Optional 16 21 Troubleshooting Tips 22 Normal Operating Sounds 22 Consumer Support Consumer Support Back...

Page 2: ...with refrigerants check with the company handling disposal about what to do SAFETY PRECAUTIONS WARNING Risk of electric shock Can cause injury or death This appliance must be properly grounded Do not...

Page 3: ...properly grounded 2 prong wall outlet by use of a UL listed adapter available at most local hardware stores n The larger slot in the adapter must be aligned with the larger slot in the wall outlet to...

Page 4: ...cally turn off in half an hour to 24 hours Each touch will set the time in half hours up to 10 and then in hours up to 24 To cancel the Off Timer press the OFF pad until the display time disappears SL...

Page 5: ...umber and the indoor air will become warmer NOTE If the air conditioner is off and is then turned on while set to COOL it will take approximately 3 minutes for the compressor to start and cooling to b...

Page 6: ...the On Timer press the ON pad until the display time disappears OFF When the air conditioner is on it can be set to automatically turn off in half an hour to 24 hours Each touch will set the time in...

Page 7: ...circulation and filtering without cooling or heating Since fan only settings do not provide cooling or heating a temperature setting will not be displayed Remote Control Press FAN pad Press LOW or HIG...

Page 8: ...CLOSE position Mesh end toward front Locating hole Screw hole The unit leaves the factory set at the CLOSE position The auxiliary dip switch controls are located behind the room cabinet as shown in t...

Page 9: ...sult from improper connections Special care must be used in connecting the wires No line voltage connections should be made to any circuit Isolate all wires in building from line voltage Terminal Conn...

Page 10: ...Hook the tabs on the front grille even with the tabs on the case and snap into place Replace the screws and filter Front Grille Outdoor Coils The coils on the outdoor side of the air conditioner shou...

Page 11: ...onditioner is to clean the filter at least every 30 days A clogged filter reduces cooling heating and air flow Keeping the air filter clean will n Decrease cost of operation n Save energy n Prevent cl...

Page 12: ...pliances com Installation Air Conditioner Instructions 12 ELECTRICAL REQUIREMENTS cont Some models require 230 208 volt a c protected with a time delay fuse or circuit breaker These models should be i...

Page 13: ...apts Whirlpool wall case to a J model chassis Wall Case Fits Whirlpool wall cases 257 8 W x 161 2 H x 231 8 D RAK1102 GE RAB30 Adapts GE wall case to a J model chassis F models Fits the RAB 30 wall ca...

Page 14: ...STALLING A J MODEL IN AN EXISTING WALL CASE Read these instructions completely and carefully Remove shipping pads if present CAREFULLY SLIDE AIR CONDITIONER BACK INTO CASE Make sure that the tubing on...

Page 15: ...the opening should be structural wall members Lintel Use a lintel in brick veneer and brick and block types of wall to support the bricks or blocks above the opening Do not allow the wall case to be u...

Page 16: ...d right hand Case side gasket 2 Vinyl window gasket Bottom window gasket Case top gasket Foam top window gasket B Right side A Left side holes are on the left holes are on the right WINDOW REQUIREMENT...

Page 17: ...pressure on the grille until it fits flush with the bottom of the case 17 STORM WINDOW REQUIREMENTS A storm window frame will not allow the air conditioner to tilt towards the outside and will keep it...

Page 18: ...require a longer adjusting bolt than the standard hex head bolt provided On wood sills use the large washer between the bolt head and the sill This prevents the bolt from digging into the wood PREPAR...

Page 19: ...and attach it to the angle Push a pencil point through the gaskets to locate the holes in the angles Install the panels in the window Place the spring clips 3 from the top and the bottom Squeeze and...

Page 20: ...With the window closed mark where the window sash meets the case Peel off the backing from the case top gasket Hold on to the case open the window and place the gasket along the mark on the case Place...

Page 21: ...e front grille An opening for the power cord is on the bottom of the front grille Fill holes and cracks with caulking provided by the installer INSTALL WINDOW GASKET AND LOCKING BRACKET Cut the foam t...

Page 22: ...of the air conditioner and contact a qualified service technician Air conditioner does Airflow is restricted Make sure there are no curtains blinds or furniture blocking not cool or heat some the fro...

Page 23: ...Replacement of house fuses or resetting of circuit breakers n Failure due to corrosion on models not corrosion protected n Damage to the product caused by improper power supply voltage accident fire f...

Page 24: ...while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your warranty expires...

Reviews: