Page 1: ...elines for energy efficiency Write the model and serial numbers here Model Serial Find these numbers on a label on the front of the base pan behind the front grille Cool Only Heat Cool AJCM 08 10 ACF AJCM 10 12 DCF AJCQ O6 LCF AJCQ 08 1O 12 ACF AJCQ 09 1O 12 DCF AJEM 12 DCE F AJEQ O6 LCE F AJEQ O8 ACE F AJEQ 09 10 12 DCE F Espa ol For a Spanish version of this manual visit our Website at GEApplian...

Page 2: ...ng disposal about what to do HOW TOCONNECT ELECTRICITY A WARNING Risk ofelect_ic shock Can cause injury or death This appliance must be properly grounded Do not under any circumstances cut or remove the third ground prong from the power cord For personal safety this appliance must be properly grounded i The power cord of this appliance is equipped with a 3 prong grounding plug which mates with a s...

Page 3: ...d with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord When disconnecting the power cord from the adapter always hold the adapter in place with one hand while pulling the power cord plug with the other hand If this is not done the adapter ground terminal is very likely to break with repeated use If the adapter ground terminal breaks DO NOTUSEthe ai...

Page 4: ...n half hours up to 10 and then in hours up to 24 To cancel the Delay Timer press the On pad until CL appears Then wait until the display turns off Off When the air conditioner is on it can be set to automatically turn off in half an hour to 24 hours Each touch will set the time in half hours up to 10 and then in hours up to 24 To cancel the Delay Timer press the Offpad until CL appears and wait fo...

Page 5: ...itioner is off and is then turned on while set to Cool it will take approximately 3 minutes for the compressor to start and cooling to begin Cooling Descriptions For Normal Cooling Select the Cool mode and High or Medfan with a middle set temperature For tfeximum Cooling Select the Cool mode and HIGHfan with a lower set temperature For Quieter and Nighttime Cooling Select the Cool mode and Lowfan ...

Page 6: ...g Each touch will set the time in half hours upto 10 and then in hours upto 24 To cancel the On Timer press the ON pad until CL appears Then wait until the display turns off OFF When the air conditioner is on it can be set to automatically turn off in half an hour to 24 hours Each touch will set the time in half hours up to 10 and then in hours up to 24 To cancel the Off Timer press the OFF pad un...

Page 7: ...2 Press LOWor HIGHpads to set desired fan speed 3 Pressthe INCREASE DECREASE pads to set the desired temperature 60 Fto 85 F in l F increments Control Panel 1 Pressthe MODEpad until the HEATindicator light is lit 2 Pressthe FANpad until HIGHor LOWindicator light is lit for desired fan speed 3 Pressthe INCREASE DECREASE pads to set the desired temperature 60 Fto 85 F in 1 Fincrements A thermostat i...

Page 8: ...witch controls are located behind the room cabinet as shown in this figure The owner is responsible for checking switches and ensuring they are in the desired position Cycle Continuous Cool Filter Reminder Function Fan Cycle Continuous Cool When this switch is enabled RIGHt it allows the indoor fan to cycle on off with the compressor When this switch is disabled LEFt it allows the indoor fan to ru...

Page 9: ...e screws and plastic cover To make wiring connections insert the wires into the bottom of the terminals and tighten screws securely r_ fter all desired connections have been made replace the plastic cover and front grille The owner is responsible for making all connections and setting the appropriate dip switches When connected the unit will be controlled by a remote thermostat NOTE The number 3 d...

Page 10: ...may be professionally steam cleaned a service available through your GE service outlet 10 Front Grille The front grille can be removed for more thorough cleaning and to locate the model and serial numbers on the front of the base pan To remove 1 Pull the filter out 2 Remove the two grille screws On some models I i On some models 3 Pull the grille out from the bottom and lift up from the tabs on th...

Page 11: ...me models Carefully pull the tab forward up and out M_ ri _ E _ 1_1C Do not operate the air conditioner without the filter in place ff a filter becomes torn or damaged it should be replaced immediately Operating without the filter in place or with a damaged filter will allow dirt and dust to reach the indoor coil and reduce the cooling heating airflow and efficiency of the unit Replacement filters...

Page 12: ...t is your responsibility and obligation to have it replaced with a properly grounded 3 prong outlet Some models require a 115 1 20 volt a c 60 Hz grounded outlet protected with a 15 amp time delay fuse or circuit breaker The 3 prong grounding plug minimizes the possibility of electric shock hazard If the wall outlet you plan to use is only a 2 prong outlet it is your responsibility to have it repl...

Page 13: ... Ruler or Tape Measure Level Scissors or knife Hand or Saber Saw GE KIT NUMBERS USE GE KIT NUMBER DESCRIPTION RAB46A 46 Standard wall case for J model chassis RAG13 stamped 47A 47 48A aluminum exterior grille included Remove the existing case 48B 48 and replace RAK65A1 Kit for window installation RAK690 RAG13 RAG14E FOR Use these kits for all GE models and other brands not listed All GE Models RAB...

Page 14: ...R INTO CASE Make sure that the tubing on the unit does not touch the wall case and that the case installation is secure jj j_ JJ _ REMOVE THE FILTER AND FRONT GRILLE Remove the two screws behind the filter then remove the front grille t P 1_ REINSTALL LOCKING PLATE WITH TAB BEHIND WALL CASE FLANGE TIGHTEN SCREW Locking plate Tighten screw iili 14 1 51 ATTACH FRONT GRILLE An opening for the power c...

Page 15: ...1 4 rain extension out from the outside wall The finished sides of the opening should be structural wall members Lintel Use a lintel in brick veneer and brick and block types of wall to support the bricks or blocks above the opening Do not allow the wall case to be used in lieu of a lintel Flashing Install flashing drip rail as shown to prevent water from dripping inside the wall and down the outs...

Page 16: ...heck for open furnace registers and cold air returns Make sure the air conditioner s vent is in the closed position Cooling coils have iced up See Air conditioner freezing up below Air conditioner Ice blocks the airflow Setthe controls at HIGHFANor HIGHCOOL and set the freezingup and stops the air conditioner thermostat to a higher temperature to allow the ice to melt from cooling the room Check f...

Page 17: ...Notes 17 ...

Page 18: ...Notes 18 ...

Page 19: ... unreasonable use including failure to provide reasonable and necessary maintenance In commercial locations labor necessary to move the unit to a location where it is accessible for service by an individual technician Replacement of house fuses or resetting of circuit breakers Failure due to corrosion on models not corrosion protected Damage to the product caused by improper power supply voltage a...

Page 20: ...e your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your warranty expires Parts and Accessories GEApplia ncespa rts corn Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discover cards are accept...