background image

2

IMPORTANT SAFETY INFORMATION.

READ ALL INSTRUCTIONS BEFORE USING

.

WARNING!

For your safety, the information in this manual must be followed to minimize the risk of fire, electric 

shock or personal injury.

„

Use this appliance only for its intended 

purpose as described in this Owner’s 

Manual. 

„

This air conditioner must be properly 

installed in accordance with the Installation 

Instructions before it is used. 

„

Never unplug your air conditioner by pulling 

on the power cord. Always grip plug firmly 

and pull straight out from the receptacle. 

„

Replace immediately all electric service 

cords that have become frayed or otherwise 

damaged. A damaged power supply cord 

must be replaced with a new power supply 

cord obtained from the manufacturer and 

not repaired. Do not use a cord that shows 

cracks or abrasion damage along its length  

or at either the plug or connector end. 

„

Turn the unit 

OFF

 and unplug your air 

conditioner before cleaning. 

„

GE does not support any servicing of the 

air conditioner. We strongly recommend 

that you do not attempt to service the air 

conditioner yourself.

„

For your safety…do not store or use 

combustible materials, gasoline or other 

flammable vapors or liquids in the vicinity  

of this or any other appliance.

„

All air conditioners contain refrigerants, 

which under federal law must be removed 

prior to product disposal. If you are getting 

rid of an old product with refrigerants, check 

with the company handling disposal about 

what to do.

„

If the receptacle does not match the plug, 

the receptacle must be changed out by a 

qualified electrician.

„

These R410A air conditioning systems 

require contractors and technicians to  

use tools, equipment and safety standards 

approved for use with this refrigerant.  

DO NOT use equipment certified for  

R22 refrigerant only.

SAFETY PRECAUTIONS

Do not, under any circumstances, cut or remove 

the third (ground) prong from the power cord.  

For personal safety, this appliance must be 

properly grounded.

  DO NOT use an adapter plug with this appliance.

The power cord of this appliance is equipped 

with a 3-prong (grounding) plug which mates 

with a standard 3-prong (grounding) wall outlet 

to minimize the possibility of electric  

shock hazard from this appliance.
Power cord includes a current interrupter device. 

A test and reset button is provided on the plug 

case. The device should be tested on a periodic 

basis by first pressing the 

TEST

 button and 

then the 

RESET

 button while plugged into the 

outlet. If the 

TEST

 button does not trip  or if the 

RESET

 button will not stay engaged, discontinue 

use of the air conditioner and contact a qualified 

service technician.

Have the wall outlet and circuit checked by  

a qualified electrician to make sure the outlet  

is properly grounded.
Where a 2-prong wall outlet is encountered,  

it is your personal responsibility and obligation to 

have it replaced with a properly grounded  

3-prong wall outlet.
The air conditioner should always be plugged 

into its own individual electrical outlet which has 

a voltage rating that matches the rating plate.
This provides the best performance and also 

prevents overloading house wiring circuits which 

could cause a fire hazard from overheated wires.
See the Installation Instructions, 

Electrical 

Requirements 

section for specific electrical 

connection requirements. 

HOW TO CONNECT ELECTRICITY

Summary of Contents for AHM18DP

Page 1: ...ustomers in the U S A 15 49 7677 12 10 GE AHM18 Owner s Manual and Installation Instructions Write the model and serial numbers here Model _________________________ Serial __________________________ F...

Page 2: ...ctrician These R410A air conditioning systems require contractors and technicians to use tools equipment and safety standards approved for use with this refrigerant DO NOT use equipment certified for...

Page 3: ...AREFULLY SAVE THESE INSTRUCTIONS WARNING USE OF EXTENSION CORDS RISK OF FIRE Could cause serious injury or death DO NOT use an extension cord with this Window Air Conditioner DO NOT use surge protecto...

Page 4: ...Pads Use to set temperature or delay time Temperature can be set in Cool Energy Saving and Auto mode Mode Pad Use to set the air conditioner to Fan Only Cool Energy Saver or Auto mode Fan Speed Pads...

Page 5: ...HOHFW WKH Cool mode and High or Med fan with a middle set temperature For Maximum Cooling 6HOHFW WKH Cool mode and High fan with a lower set temperature For Quieter and Nighttime Cooling 6HOHFW WKH Co...

Page 6: ...f necessary To remove Open the inlet grille by pulling downward on the tabs at the top upper corners of the inlet grille until the grille is in a 45 position Remove the filter Clean the filter with wa...

Page 7: ...y to have it replaced with a properly grounded 3 prong wall outlet Some models require 230 208 volt AC protected with a time delay fuse or circuit breaker These models should be installed on their own...

Page 8: ...DED Appearance may vary 13 32 Screws 12 Installation Bracket 2 Window Lock Bracket Remote Control Top Mounting Rail Left and Right Side Curtains Foam Seal 13 32 Screws 6 31 32 Screws 8 2 1 2 Flat Head...

Page 9: ...to fit in a narrow window See the window opening dimensions All supporting parts must be secured to firm wood masonry or metal The electrical outlet must be within reach of the power cord Follow the...

Page 10: ...INSTALLATION Measure the width of the window opening Mark the center line on the inside windowsill 5 B A B A A Width of window opening B Center line INSTALL OUTER CASE IN WINDOW Place outer case in wi...

Page 11: ...f the bolt rests between studs D E 5 6 COMPLETE INSTALLATION Insert the foam seal behind the top of the lower window sash and against the glass of the upper window Place the window lock bracket as sho...

Page 12: ...ave two people lift the air conditioner and slide it into the case Snap the front grille back onto the air conditioner Use the screws removed at the beginning of the installation to secure the grille...

Page 13: ...ow time for the room to cool down Cold air is escaping KHFN IRU RSHQ IXUQDFH UHJLVWHUV DQG FROG DLU UHWXUQV Cooling coils have iced up 6HH LU FRQGLWLRQHU IUHH LQJ XS EHORZ Air conditioner Ice blocks t...

Page 14: ...14 Note...

Page 15: ...accessible for service by an individual technician Replacement of house fuses or resetting of circuit breakers Failure due to corrosion on models not corrosion protected Damage to the product caused...

Page 16: ...Inc Suite 310 1 Factory Lane Moncton N B E1C 9M3 Parts and Accessories In the U S A GEAppliances com Individuals qualified to service their own appliances can have parts or accessories sent directly t...

Page 17: ...Sonidos Normales de Funcionamiento 11 Soporte al Cliente Garant a para Clientes en EE UU 13 Soporte al Cliente 14 Manual del Propietario e Instrucciones de Instalaci n Escriba los n meros de modelo y...

Page 18: ...mplazar el recept culo Estos sistemas de acondicionadores de aire R410A requieren que los contratistas y t cnicos usen herramientas equipos y est ndares de seguridad aprobados para su uso con este ref...

Page 19: ...DOSAMENTE GUARDE ESTAS INSTRUCCIONES RIESGO DE INCENDIO Podr a ocasionar lesiones graves o la muerte NO use un prolongador con este Acondicionador de Aire de Ventana NO use protectores contra picos de...

Page 20: ...de entre 1 y 24 horas C mo configurar Presione la tecla Delay 1 24hr Retraso entre 1 y 24 hrs en la unidad o en el control remoto Cada vez que presione las teclas Increase Incrementar Decrease Reduci...

Page 21: ...eleccione el modo Cool Fr o y ventilador Low Bajo con una temperatura de ajuste media Modo de Fan Only Solo ventilador Use el modo Fan only Solo ventilador a velocidad Low Baja Med Media o High Alta p...

Page 22: ...ue los polos positivos y negativos est n orientados correctamente 3 Coloque la cubierta otra vez desliz ndola en su lugar NOTAS Use 2 pilas alcalinas AAA de 1 5 voltios No use pilas recargables Retire...

Page 23: ...acondicionador de aire Los cables caseros de aluminio podr an presentar problemas especiales Consulte a un t cnico electricista calificado ANTES DE INICIAR Lea estas instrucciones completa y cuidados...

Page 24: ...i n 8 Temp Delay PARTES INCLUIDAS Apariencia puede variar Taladro y broca de 1 8 Llave francesa Riel de montaje superior Sellador de Gomaespuma Cortinas Izquierda y Derecha Soporte de Instalaci n 2 So...

Page 25: ...a una ventana est ndar de dos pliegues Usted necesitar modificar el proceso para otros tipos de ventanas Todas las partes de apoyo deben quedar totalmente aseguradas a alg n metal mamposter a o a la m...

Page 26: ...entana 5 B A B A A Width of window opening B Center line INSTALE LA CAJA EXTERIOR EN LA VENTANA Coloque la caja exterior en la ventana Baje el marco hasta que se apoye detr s de la pesta a frontal del...

Page 27: ...D E 5 6 INSTALACI N COMPLETA Inserte el sello de gomaespuma detr s de la parte superior del marco de la ventana y contra el vidrio de la ventana superior Coloque el soporte de bloqueo de la ventana co...

Page 28: ...ondicionador de aire Use los tornillos retirados al comenzar la instalaci n para asegurar la parrilla 7 REGRESE EL CHASIS A LA CAJA EXTERNA Enchufe en un tomacorriente de 3 patas con conexi n a tierra...

Page 29: ...aliente necesita darle tiempo para que enfri la habitaci n O DLUH IUtR VH HVWi HVFDSDQGR HUFLyUHVH GH TXH ORV UHJLVWURV GH OD FDOHIDFFLyQ QR HVWiQ abiertos y se encuentran retornando el aire fr o DV E...

Page 30: ...Esta garant a se extiende al comprador original y cualquier comprador posterior de productos comprados para uso residencial dentro de Estados Unidos Si el producto est situado en un rea que no dispon...

Page 31: ...personas con dificultades auditivas favor de llamar al 800 TDD GEAC 800 833 4322 Piezas y accesorios GEAppliances com Aquellos individuos con la calificaci n necesaria para reparar sus propios electro...

Page 32: ...ite 310 1 Factory Lane Moncton N B E1C 9M3 Parts and Accessories In the U S A GEAppliances com Individuals qualified to service their own appliances can have parts or accessories sent directly to thei...

Reviews: