background image

Consumer Support

Troubleshooting T

ips

Operating Instructions

Safety Instructions

Installation Instructions

4

■ 

To ensure proper operation, aim the 
remote control at the signal receiver 
on the air conditioner.

■ 

The remote control signal has a range of up 
to 21 feet.

■ 

Make sure nothing is between the air 
conditioner and the remote control 
that could block the signal.

■ 

Make sure batteries are fresh and installed
correctly as indicated on the remote control.

About the controls on the air conditioner—models with touch pads.

Features and appearance will vary.

Controls

ON/OFF Pad

Turns air conditioner on and off.

Display

Shows the set temperature or time remaining
on timer.

MODE

Use to set the air conditioner to 

COOL

or 

FAN

mode. 

Increase 

▲ 

/Decrease 

Pads

Use to set temperature when in 

COOL

mode.

FAN Pad

Use to set the fan speed to 

LOW (F1), MED (F2)

or 

HIGH (F3).

ENERGY SAVER –

Controls the fan.

(on some models)

ON – 

The fan and compressor cycle on and

off. This results in wider variations of room
temperature and humidity. Normally used
when the room is unoccupied. 

Note:

The fan

will continue to run for a short time after the
compressor cycles off.

OFF – 

The fan runs all the time, while the

compressor cycles on and off.

This feature must be set at 

OFF

in order to use

the fan settings (on the mode control).

Note: 

On some models, the 

ENERGY SAVER

feature cannot be set on the air conditioner. 
It must be set using the remote control.

CIRCULAIRE 

(on some models)

For continuous side-to-side air circulation
(cool settings only), set the Circulaire switch 
to 

ON

.

For fixed side-to-side air direction, turn 

ON

until the desired air direction is obtained,
then turn it 

OFF

.

TIMER Pad

ON – 

When the air conditioner is off, it can be

set to automatically come on in 1 to 12 hours
at its previous setting. Each touch will set the
timer in hours.

OFF – 

When the air conditioner is on, it can be

set to automatically turn off in 1 to 12 hours.
Each touch will set the timer in hours. After
the timer has been on for 30 minutes, the
temperature will automatically rise 2°F, and
after another 30 minutes, it will automatically
rise 2°F again. The temperature will then stay
the same until the timer goes 

OFF

.

To cancel the timer,

press the 

TIMER

pad until

the display time disappears.

Remote Control Signal Receiver

Remote Control

Air Conditioner Controls

Remote Control

FAN

Cool on

Fan on

Energy
Saver on

Timer on

Summary of Contents for AGH24

Page 1: ...4 Troubleshooting Tips 15 16 Normal Operating Sounds 16 Consumer Support Consumer Support 20 Product Registration 17 18 Warranty 19 3828A20145P 49 7429 12 01 JR Owner s Manual and Installation Instruc...

Page 2: ...in the vicinity of this or any other appliance SAFETY PRECAUTIONS Do not under any circumstances cut or remove the third ground prong from the power cord For personal safety this appliance must be pr...

Page 3: ...de to a properly grounded 2 prong wall outlet by use of a UL listed adapter available at most local hardware stores The larger slot in the adapter must be aligned with the larger slot in the wall outl...

Page 4: ...n for a short time after the compressor cycles off OFF The fan runs all the time while the compressor cycles on and off This feature must be set at OFF in order to use the fan settings on the mode con...

Page 5: ...OL mode and HIGH F3 or MED F2 fan with a middle set temperature For Maximum Cooling Select the COOL mode and HIGH F3 fan with a lower set temperature For Quieter Nighttime Cooling Select the COOL mode...

Page 6: ...number available on your knob For Quieter Nighttime Cooling Select LOW COOL with the temp control at midpoint Temp Controls The temp control is used to maintain the room temperature The compressor wi...

Page 7: ...esired air direction is obtained then move it to OFF For continuous side to side air circulation cool settings only set the Circulaire switch to ON Air Direction Up and Down Fingertip pressure on the...

Page 8: ...ION DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance 2 1 Outdoor Coils The coils on the outdoor side of the air conditioner should be check...

Page 9: ...cord Do not change the plug on the power cord of this air conditioner Aluminum house wiring may present special problems consult a qualified electrician Before You Begin Some models require 115 120 v...

Page 10: ...pe D 2 Carriage Bolt 2 Lock Nut 4 Window locking bracket Frame guide 2 Top mounting rail Top mounting rail seal strip Right accordion panel Foam top window gasket Window sash seal Left accordion panel...

Page 11: ...od masonry or metal The electrical outlet must be within reach of the power cord 18 min 29 to 41 With accordion panels 261 4 min Without accordion panels Storm Window Requirements A storm window frame...

Page 12: ...Insert the frames for the accordion panels into the top mounting rail and the frame guides Attach the accordion panels to the side of the case using 5 type A screws D C B A Remove the Air Conditioner...

Page 13: ...aligning the center front on the bottom with the centerline marked on the window stool Close the window making sure the window sash is behind the top mounting rail Using the larger diameter hole in t...

Page 14: ...the grille in until it snaps into place Lift the inlet grille and secure the front frame with a type A screw Lower the inlet grille into place D C B A 8 Install the Window Locking Bracket and the Foam...

Page 15: ...heck for open furnace floor registers and cold air returns Set the air conditioner s vent to the closed position Cooling coils have iced up See Air conditioner freezing up below Air conditioner Ice bl...

Page 16: ...picked up and thrown against the condenser on rainy days or when the humidity is high This design feature helps remove moisture and improve efficiency You may hear the thermostat click when the compr...

Page 17: ...will be completely satisfied with our service protection or you may request your money back on the remaining value of your contract No questions asked It s that simple Protect your refrigerator dishwa...

Page 18: ...duct is registered or register online at GEAppliances com 1 2 3 Model Number Serial Number Cut here Complete and mail your Consumer Product Ownership Registration today Have the peace of mind of knowi...

Page 19: ...provide reasonable and necessary maintenance In commercial locations labor necessary to move the unit to a location where it is accessible for service by an individual technician Replacement of house...

Page 20: ...arranty and learn about special discounts that are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Ho...

Page 21: ...deas para la identificaci n y reparaci n de problemas 15 16 Sonidos normales de operaci n 16 Apoyo al consumidor Apoyo al consumidor 20 Garant a 19 3828A20145P 49 7429 12 01 JR Manual del Propietario...

Page 22: ...quidos inflamables en la proximidad de ste o alg n otro electrodom stico PRECAUCIONES DE SEGURIDAD Bajo ninguna circunstancia corte o retire la tercera p a tierra del cable el ctrico En pos de la segu...

Page 23: ...iente listado UL disponible en la mayor a de las ferreter as La ranura mayor en el adaptador debe estar alineada con la p a mayor en la pared para proporcionar una polaridad apropiada en la conexi n d...

Page 24: ...encendido y apagado Esta funci n debe estar colocada en OFF APAGADO para usar las funciones del ventilador en el modelo de control Nota En algunos modelos la funci n de ENERGY SAVER AHORRADOR DE ENER...

Page 25: ...do de ventilador COOL y HIGH F3 ALTO con una temperatura de ajuste menor Para enfriamiento silencioso enfriamiento nocturno Seleccione el modo de ventilador COOL FR O y LOW F1 BAJO con una temperatura...

Page 26: ...on el control de temperatura en un n mero mayor disponible en su teclado Para enfriamiento silencioso durante la noche Seleccione LOW COOL ENFRIAMIENTO BAJO con el control de temperatura en el nivel m...

Page 27: ...IRCULADOR DE AIRE a la posici n ON ENCENDIDO y d jelo as Direcci n del aire Hacia arriba y hacia abajo Una presi n sencilla con los dedos en parte posterior de la persianita horizontal ajustar la dire...

Page 28: ...N NO opere el acondicionador de aire sin el filtro debido a que la suciedad y las pelusas lo obstruir n y reducir n su rendimiento 2 1 Bobinas para exteriores Las bobinas en el lado exterior del acond...

Page 29: ...tricista calificado ANTES DE COMENZAR Algunos modelos requieren tomacorrientes de 115 120 voltios de corriente alterna y 60 Hz conectado a tierra protegido con un fusible de dilataci n de tiempo de 15...

Page 30: ...e 4 Soporte de cierre de la ventana Gu a del marco 2 Riel de montaje superior Cinta de sellado del riel de montaje Panel de acorde n derecho Parte superior de la espuma de la junta de la ventana Banda...

Page 31: ...m nimo sin paneles de acorde n 1 Requisitos de una ventana de tormentas Un marco de ventana de tormentas no permitir que el acondicionador de aire se incline hacia el exterior y evitar que drene aprop...

Page 32: ...arcos para los paneles de acorde n en el riel de montaje superior y las gu as del marco Una los paneles de acorde n al lado de la caja usando 5 tornillos tipo A D C B A Retire el acondicionador de air...

Page 33: ...dose de que la banda est detr s del riel de montaje superior Usando el agujero de mayor di metro en la caja pegue los soportes a la caja usando 2 tornillos tipo D y 2 tuercas se cierre en cada lado Aj...

Page 34: ...rrilla hasta que encaje en su lugar Levante la parrilla de entrada y aseg rela al marco frontal con un tornillo tipo A Baje la parrilla de entrada a su lugar D C B A 8 Instale el soporte de cierre de...

Page 35: ...la calefacci n no est n abiertos y se encuentran retornando el aire fr o Coloque la ventanilla del acondicionador de aire en la posici n cerrada Las bobinas de enfriamiento Ver Acondicionador de aire...

Page 36: ...uando el compresor hace ciclo entre encendido y apagado El agua se acumula en la bandeja durante d as lluviosos o con mucha humedad El agua podr a derramarse y gotear desde el lado externo de la unida...

Page 37: ...17 Apoyo al consumidor Soluci n de problemas Instrucciones de operaci n Instrucciones de seguridad Instrucciones de instalaci n Notas...

Page 38: ...18 Notas Apoyo al consumidor Soluci n de problemas Instrucciones de operaci n Instrucciones de seguridad Instrucciones de instalaci n...

Page 39: ...para revisi n por parte de un t cnico individual Reemplazo de fusibles de la casa o reajuste del sistema de circuitos Fallos debido a la corrosi n en modelos que no est n protegidos contra la corrosi...

Page 40: ...a detalles sobre descuentos especiales disponibles mientras su garant a est a n activa Puede comprarla en l nea en cualquier momento o llamar al 800 626 2224 durante horas normales de oficina GE Consu...

Reviews: