background image

Operating Instr

uctions

Safety Instr

uctions

Installation Instr

uctions

Tr

oubleshooting T

ips

Customer Ser

vice

Service Telephone Numbers.

GE Answer Center

®

800.626.2000

The GE Answer Center® is open 24 hours a day, 7 days a week. 

In-Home Repair Service 

800-GE-CARES (800-432-2737)

Expert GE repair service is only a phone call away. 

Special Needs Service 

800.626.2000

800-TDD-GEAC (800-833-4322)

GE offers, free of charge, a brochure to assist in planning a barrier-free kitchen for persons 

with limited mobility.

Service Contracts 

800-626-2224

Purchase a GE service contract while your warranty is still in effect and you’ll receive a 

substantial discount. GE Consumer Service will still be there after your warranty expires.

Parts and Accessories 

800-626-2002

Individuals qualified to service their own appliances can have parts or accessories sent directly 

to their homes (VISA, MasterCard and Discover cards are accepted). 

Instructions contained in this manual cover procedures to be performed by any user. Other servicing
generally should be referred to qualified service personnel. Caution must be exercised, since
improper servicing may cause unsafe operation. 

Service Satisfaction 

If you are not satisfied with the service you receive from GE: 

First, 

contact the people who serviced your appliance. 

Next, 

if you are still not pleased, write all the details—including your phone number—to:

Manager, Consumer Relations

GE Appliances

Appliance Park

Louisville, KY 40225

Finally, 

if your problem is still not resolved, write: 

Major Appliance Consumer Action Program

20 North Wacker Drive

Chicago, IL 60606

Printed in Korea

16

Summary of Contents for AGH08

Page 1: ...GE Appliances Room Air Conditioners Pub No 49 7368 2 CG 12 97 AGH08 AGP08 AGV08 Owner s Manual Installation Instructions...

Page 2: ...er 7 Window Installation 8 12 Troubleshooting Tips Before You Call For Service 13 Normal Operating Sounds 13 Customer Service Warranty 15 Service Telephone Numbers Back Cover FOR YOUR RECORDS Write th...

Page 3: ...Because most 2 prong outlets are not grounded we strongly advise against using an adapter plug However a temporary connection may be made where local codes permit and if the 2 prong wall outlet is pro...

Page 4: ...OFF or to a fan setting wait at least 3 minutes before switching back to a cool setting Cooling Descriptions For Normal Cooling Select HIGH COOL or MED COOL with the temp control at midpoint For Maxim...

Page 5: ...austed outside To open the vent pull the lever toward you To close it push it in Air Direction The horizontal air direction is adjusted by moving the lever to the left or right Fingertip pressure on t...

Page 6: ...d by pulling out the bottom of the inlet grille Using the tab pull up slightly on the filter to release it and pull it down Clean the filter with warm soapy water Rinse and let the filter dry before r...

Page 7: ...w National Electric Codes NEC and or local codes and ordinances CAUTION Do not under any circumstances cut or remove the third ground prong from the power cord Do not change the plug on the power cord...

Page 8: ...ating Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions Window Installation Instructions Parts Included Type A 16 Sill support 2 W...

Page 9: ...outlet must be within reach of the power cord Window opening dimensions are for a standard double hung window 14 min 25 to 36 With accordion panels 201 8 min Without accordion panels Storm Window Requ...

Page 10: ...he bottom of the case on each side Remove the backing from the top mounting rail seal strip and attach it to the bottom of the top mounting rail Install the top mounting rail with 3 type A screws on t...

Page 11: ...estricted Loosely assemble the sill supports Select the position that will place the sill supports near the outermost point on the sill Attach the sill supports to the case track hole in relation to t...

Page 12: ...top window gasket to the window width Stuff the foam between the glass and the window to prevent air and insects from getting into the room C B A 6 Install the Air Conditioner in the Case Slide the a...

Page 13: ...highest setting not be set high enough provides maximum cooling The air filter is dirty Clean the filter at least every 30 days See the Operating Instructions section The room may have been hot When...

Page 14: ...afety Instructions Installation Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions Customer Service Troubleshooting Tips Installati...

Page 15: ...your dealer or installer You are responsible for providing adequate electrical connecting facilities Failure of the product resulting from modifications to the product or due to unreasonable use incl...

Page 16: ...anty expires Parts and Accessories 800 626 2002 Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discover cards are...

Reviews: