background image

IMPORTANT SAFETY INFORMATION.
READ ALL INSTRUCTIONS BEFORE USING.

WARNING!

For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock
or personal injury.

■ 

Use this appliance only for its intended

purpose as described in this Owner’s

Manual. 

This air conditioner must be properly

installed in accordance with the Installation

Instructions before it is used. 

Never unplug your air conditioner by pulling

on the power cord. Always grip plug firmly

and pull straight out from the receptacle. 

■ 

Repair or replace immediately all electric

service cords that have become frayed or

otherwise damaged. Do not use a cord that

shows cracks or abrasion damage along its

length or at either the plug or connector end. 

■ 

Turn the mode control to 

OFF

and unplug

your air conditioner before making any

repairs or cleaning. 

NOTE:

We strongly recommend that any

servicing be performed by a qualified

individual.

■ 

For your safety…do not store or use

combustible materials, gasoline or other

flammable vapors or liquids in the vicinity 

of this or any other appliance. 

SAFETY PRECAUTIONS

3

Customer Service

Troubleshooting T

ips

Operating Instructions

Safety Instructions

Installation Instructions

Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord. For
personal safety, this appliance must be properly
grounded.

The power cord of this appliance is equipped

with a 3-prong (grounding) plug which mates

with a standard 3-prong (grounding) wall

outlet to minimize the possibility of electric 

shock hazard from this appliance.
Have the wall outlet and circuit checked by a

qualified electrician to make sure the outlet is

properly grounded.
Where a 2-prong wall outlet is encountered, 

it is your personal responsibility and obligation

to have it replaced with a properly grounded 

3-prong wall outlet.

The air conditioner should always be 

plugged into its own individual electrical 

outlet which has a voltage rating that matches

the rating plate.
This provides the best performance and also

prevents overloading house wiring circuits

which could cause a fire hazard from

overheated wires.
See the Installation Instructions, 

Electrical

Requirements

section for specific electrical

connection requirements. 

HOW TO CONNECT ELECTRICITY

Summary of Contents for AG_07 Series

Page 1: ...Room Air Conditioners Pub No 49 7390 JR 10 99 AG_07 7 000 BTU models AG_08 8 000 BTU models AG_10 10 000 BTU models AG_12 12 000 BTU models Owner s Manual Installation Instructions www geappliances co...

Page 2: ...ginal purchase date is needed to obtain service under the warranty Inside you will find many helpful hints on how to use and maintain your air conditioner properly Just a little preventive care on you...

Page 3: ...in the vicinity of this or any other appliance SAFETY PRECAUTIONS 3 Customer Service Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Do not under any circums...

Page 4: ...ary connection may be made to a properly grounded 2 prong wall outlet by use of a UL listed adapter available at most local hardware stores The larger slot in the adapter must be aligned with the larg...

Page 5: ...p control at midpoint For Maximum Cooling Select HIGH COOL with the temp control at the highest number available on your knob For Quieter Nighttime Cooling Select LOW COOL with the temp control at mid...

Page 6: ...in Air Direction Side to Side On some models the side to side air direction is adjusted by moving the lever to the left or right CIRCULAIRE on some models For fixed side to side air direction set the...

Page 7: ...thout a filter because dirt and lint will clog it and reduce performance 2 1 Outdoor Coils The coils on the outdoor side of the air conditioner should be checked regularly If they are clogged with dir...

Page 8: ...odes and ordinances CAUTION Do not under any circumstances cut or remove the third ground prong from the power cord Do not change the plug on the power cord of this air conditioner Aluminum house wiri...

Page 9: ...rail Top mounting rail seal strip Right accordion panel Foam top window gasket Window sash seal Left accordion panel Type B 3 Type C 5 Bolt 2 Nut 2 Customer Service Troubleshooting Tips Operating Inst...

Page 10: ...s below 7 000 and 8 000 BTU models All supporting parts must be secured to firm wood masonry or metal The electrical outlet must be within reach of the power cord 10 000 and 12 000 BTU models 16 min 2...

Page 11: ...for the accordion panels into the top mounting rail and the frame guides Attach the accordion panels to the side of the case using 4 type A screws on each side D C B A Remove the Air Conditioner From...

Page 12: ...il NOTE Do not shut the window so tightly that movement of the accordion panels is restricted Loosely assemble the sill supports Select the position that will place the sill supports near the outermos...

Page 13: ...earlier on each side of the case Before installing the front grille pull out the vent control lever located above the unit control knobs as shown Attachthefrontgrilletothecasebyinsertingthe tabsonthe...

Page 14: ...should blocking the front of the air conditioner The temp control may Turn the knob to a higher number The highest setting not be set high enough provides maximum cooling The air filter is dirty Clean...

Page 15: ...15 Notes Customer Service Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions...

Page 16: ...afety Instructions Installation Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions Customer Service Troubleshooting Tips Installati...

Page 17: ...tection or you may request your money back on the remaining value of your contract No questions asked It s that simple Protect your refrigerator dishwasher washer and dryer range TV VCR and much more...

Page 18: ...ensure that your product is registered or register online at www geappliances com 1 2 3 Model Number Serial Number Cut here Complete and mail your Consumer Product Ownership Registration today Have th...

Page 19: ...er or installer You are responsible for providing adequate electrical connecting facilities Failure of the product resulting from modifications to the product or due to unreasonable use including fail...

Page 20: ...discount GE Consumer Service will still be there after your warranty expires Parts and Accessories 800 626 2002 Individuals qualified to service their own appliances can have parts or accessories sen...

Reviews: