background image

Consumer Product Ownership Registration

Im

po

rta

nt

Ma

il 

To

da

y!

GE Appliances

GE Consumer & Industrial
Louisville, Kentucky
www.GEAppliances.com

First

Name

Mr. 

Ms. 

Mrs. 

Miss 

Street

Address

City

State

Date Placed

In Use

Month

Day

Year

Zip

Code

Apt. #

Last

Name

Phone

Number

_

_

Consumer Product Ownership Registration

Dear Customer:
Thank you for purchasing our product and thank you for placing your confidence in us. 
We are proud to have you as a customer!

Follow these three steps to protect your new appliance investment:

Important: If you did not get a registration card with your 

product, detach and return the form below to 
ensure that your product is registered, or register
online at www.GEAppliances.com.

1 2 3

Model Number

Serial Number

Cut here

Complete and mail
your Consumer
Product Ownership
Registration today.

Have the peace of
mind of knowing we
can contact you in
the unlikely event of a
safety modification.

After mailing the
registration below, 
store this document 
in a safe place. It
contains information
you will need should 
you require service. 
Our service number is
800.GE.CARES 
(800.432.2737).

Read your Owner’s
Manual carefully.
It will help you
operate your new
appliance properly.

Model Number

Serial Number

E-mail Address*

* Please provide your e-mail address to receive, via e-mail, discounts, special offers and other important

communications from GE Appliances (GEA).

■ 

Check here if you do not want to receive communications from GEA’s carefully selected partners.

FAILURE TO COMPLETE AND RETURN THIS CARD DOES NOT DIMINISH YOUR WARRANTY
RIGHTS.

For information about GEA’s privacy and data usage policy, go to www.GEAppliances.com and click on
“Privacy Policy” or call 800.626.2224.

18

Summary of Contents for AFQ08 Series

Page 1: ...mal Operating Sounds 16 Consumer Support Consumer Support 20 Product Registration 17 18 Warranty 19 TINSC2317C2R0 49 7486 02 04 JR Owner s Manual and Installation Instructions Write the model and serial numbers here Model __________________________ Serial __________________________ Find these numbers on a label on the side of the air conditioner Air Conditioners Room www GEAppliances com ...

Page 2: ...aw must be removed prior to product disposal If you are getting rid of an old product with refrigerants check with the company handling disposal about what to do SAFETY PRECAUTIONS Do not under any circumstances cut or remove the third ground prong from the power cord For personal safety this appliance must be properly grounded The power cord of this appliance is equipped with a 3 prong grounding ...

Page 3: ...rounded 2 prong wall outlet by use of a UL listed adapter available at most local hardware stores The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord When disconnecting the power cord from the adapter always hold the adapter in place with one hand while pulling the power cord plug with the other hand ...

Page 4: ...DE Use to set the air conditioner to COOL DEHUM Dehumidification or FAN mode Increase Decrease Pads Use to set temperature when in COOL mode FAN Use to set the fan speed at HIGH F3 MED F2 or LOW F1 AUTO ON OFF ON When the air conditioner is off it can be set to automatically turn on in 1 to 24 hours at its previous setting Each touch will set the time in hours OFF When the air conditioner is on it...

Page 5: ...the compressor to start and cooling to begin Cooling Descriptions For Normal Cooling Select the COOL mode and HIGH F3 MED F2 or LOW F1 fan with a middle set temperature For Maximum Cooling Select the COOL mode and HIGH F3 fan with a lower set temperature For Quieter Nighttime Cooling Select the COOL mode and LOW F1 fan with a middle set temperature COOL Mode Use the FAN at HIGH F3 MED F2 or LOW F1...

Page 6: ...arly If they are clogged with dirt or soot they may be professionally steam cleaned a service available through your GE service outlet Outdoor Coils The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary Clean the filter with warm soapy water Rinse and let the filter dry before replacing it NOTE DO NOT put the filter in an automatic d...

Page 7: ... grounded outlet protected with a 15 amp time delay fuse or circuit breaker The 3 prong grounding plug minimizes the possibility of electric shock hazard If the wall outlet you plan to use is only a 2 prong outlet it is your responsibility to have it replaced with a properly grounded 3 prong wall outlet Some models require 230 208 volt a c protected with a time delay fuse or circuit breaker These ...

Page 8: ... Foam top window gasket Window sash seal thin adhesive backed Left accordion panel Type B 9 Top mounting rail seal strip Top mounting rail Window locking bracket Sill support 2 Nut 2 Bolt 2 8 Installation Instructions PARTS INCLUDED ...

Page 9: ...power cord 1 151 2 min 241 2 to 37 With accordion panels 173 4 min Without accordion panels STORM WINDOW REQUIREMENTS A storm window frame will not allow the air conditioner to tilt toward the outside and will keep it from draining properly To adjust for this attach a piece of wood to the stool WOOD PIECES WIDTH 2 LENGTH Long enough to fit inside the window frame THICKNESS To determine the thickne...

Page 10: ...le pressing in on the case sides with your finger tips Pull out to release and lift it up NOTE Do not pull the bottom edge toward you more than 3 or you may damage the tabs of the grille Remove the screw from each side of the case Keep them in a safe location Slide the air conditioner from the case by gripping the base pan handle and pulling forward while bracing the case E F D 10 Installation Ins...

Page 11: ...p of the case with 4 Type A screws B Type A screws 11 Installation Instructions Remove and discard the shipping pad INSTALL THE TOP MOUNTING RAIL ONTO THE CASE Remove the backing from the top mounting rail seal strip and attach it to the bottom of the top mounting rail 5 A Seal strip Top mounting rail Top mounting rail Bottom ...

Page 12: ...h the accordion panels to the case using 4 Type A screws on each side 6 A B Type A screws Top mounting rail Bottom mounting rail Accordion panel PREPARE THE WINDOW Cut the window sash seal to the window width and stick the adhesive side to the bottom of the sash 7 Window sash seal 12 Installation Instructions BACK INSIDE ...

Page 13: ...sill supports near the outermost point on the sill Attach the sill supports to the case track hole in relation to the selected position using 2 type A screws in each support 8 Bolt Nut Sill support OUTDOOR INDOOR INSTALL THE CASE IN THE WINDOW CONT Adjust the bolt and the nut in each support so that the case is installed with a slight tilt to the outside Use a level about 1 2 bubble will be the co...

Page 14: ... removed earlier one on each side of the case Attach the front grille to the case by inserting the tabs on the grille into the slots on the front top of the case Push the grille in until it snaps into place around the power cord on the right side Secure the front grille to the case by replacing the 3 screws removed earlier Install the filter Connect power 10 B C INSIDE 9 INSTALL THE AIR CONDITIONE...

Page 15: ...ner freezing up below Air conditioner Ice blocks the air flow and Set the controls at HIGH FAN or HIGH COOL and set the freezing up stops the air conditioner thermostat to a higher temperature from cooling the room Water drips outside Hot and humid weather This is normal Water drips indoors The air conditioner is not For proper water disposal make sure the air conditioner tilted to the outside sla...

Page 16: ...y days or when the humidity is high This design feature helps remove moisture and improve efficiency You may hear the thermostat click when the compressor cycles on and off Water will collect in the base pan during high humidity or on rainy days The water may overflow and drip from the outdoor side of the unit The fan may run even when the compressor does not Normal Operating Sounds Before you cal...

Page 17: ... protection or you may request your money back on the remaining value of your contract No questions asked It s that simple Protect your refrigerator dishwasher washer and dryer range TV VCR and much more any brand Plus there s no extra charge for emergency service and low monthly financing is available Even icemaker coverage and food spoilage protection is offered You can rest easy knowing that al...

Page 18: ... Complete and mail your Consumer Product Ownership Registration today Have the peace of mind of knowing we can contact you in the unlikely event of a safety modification After mailing the registration below store this document in a safe place It contains information you will need should you require service Our service number is 800 GE CARES 800 432 2737 Read your Owner s Manual carefully It will h...

Page 19: ...ary maintenance In commercial locations labor necessary to move the unit to a location where it is accessible for service by an individual technician Replacement of house fuses or resetting of circuit breakers Failure due to corrosion on models not corrosion protected Damage to the product caused by improper power supply voltage accident fire floods or acts of God Incidental or consequential damag...

Page 20: ...discounts that are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your warranty expires Parts and Accessories www GEAppliances com Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard ...

Page 21: ... 15 Sonidos normales de operación 16 Apoyo al consumidor Apoyo al consumidor 20 Garantía 19 TINSC2317C2R0 49 7486 02 04 JR AFQ08 Acondicionadores de Aire Manual del Propietario e Instrucciones de Instalación www GEAppliances com Escriba el modelo y número de serie aquí Número de modelo ______________ Número de serie ________________ Usted puede encontrar estos números al costado del acondicionador...

Page 22: ...frigerantes los cuales se deben retirar antes de la eliminación del producto de acuerdo con la ley federal Si va a desechar algún aparato antiguo de refrigeración consulte con la compañía a cargo de desechar el aparato para saber qué hacer PRECAUCIONES DE SEGURIDAD Bajo ninguna circunstancia corte o remueva la tercera púa tierra del cable eléctrico En pos de la seguridad personal este electrodomés...

Page 23: ... disponible en la mayoría de las ferreterías La ranura mayor en el adaptador debe estar alineada con la púa mayor en la pared para proporcionar una polaridad apropiada en la conexión del cable eléctrico Cuando se disponga a desconectar el cable eléctrico del adaptador siempre sostenga el adaptador en su lugar con una mano mientras tira del cable eléctrico con la otra mano Si no hace esto la termin...

Page 24: ... la velocidad del ventilador a HIGH ALTO F3 MED MEDIANO F2 o LOW BAJO F1 AUTO ON OFF ON Cuando el acondicionador de aire está apagado se puede ajustar para que se encienda automáticamente de 1 a 24 horas en la última selección en que estuvo Cada toque aumentará o disminuirá la selección en una hora OFF Cuando el acondicionador de aire está encendido se puede ajustar para que se apague automáticame...

Page 25: ...TO F3 MED MEDIANO F2 o LOW BAJO F1 con una temperatura de ajuste media Para enfriamiento máximo Seleccione el modo de ventilador COOL FRÍO y HIGH ALTO F3 con una temperatura de ajuste menor Para enfriamiento silencioso y enfriamiento nocturno Seleccione el modo de ventilador COOL FRÍO y LOW BAJO F1 con una temperatura de ajuste media Dirección del aire Hacia arriba y hacia abajo Una presión sencil...

Page 26: ...ara retirar Usando la lengüeta tire del filtro hacia la derecha para removerlo Bobinas para exteriores Las bobinas en el lado exterior del acondicionador de aire debe ser inspeccionada regularmente Si la misma está obstruida con suciedad u hollín podría ser limpiada profesionalmente con vapor y nosotros en GE podemos proporcionarle tales servicios Parrilla y caja Apague el acondicionador de aire y...

Page 27: ...mpo de 15 amperios o un cortacircuitos El enchufe de tres púas con conexión a tierra minimiza la posibilidad de descargas eléctricas Si el tomacorriente de la pared que usted planea usar solamente tiene 2 tomas es su responsabilidad hacer que un técnico lo reemplace por uno de tres tomas con conexión a tierra REQUISITOS ELECTRICOS HERRAMIENTAS QUE USTED NECESITARÁ Destornillador Phillips Llave aju...

Page 28: ...del marco de la ventana fino con adhesivo en la parte posterior Panel de acordeón izquierdo Tipo B 9 Cinta de sellado del riel de montaje Riel de montaje superior Soporte para bloqueo de ventana Soporte del umbral 2 Tuerca 2 Perno 2 PARTES INCLUIDAS 8 Instrucciones para la instalación ...

Page 29: ...r de aire 1 151 2 mín 241 2 a 37 con paneles de acordeón 173 4 mín sin paneles de acordeón REQUISITOS DE UNA VENTANA DE TORMENTAS Un marco de ventana de tormentas no permitirá que el acondicionador de aire se incline hacia el exterior y evitará que drene apropiadamente Para solucionar este problema adhiera un pedazo de madera a la repisa PIEZAS DE MADERA ANCHO 2 LONGITUD Suficiente longitud para a...

Page 30: ... hacia adentro en los lados de la caja con las puntas de sus dedos Tire hacia afuera para liberarla y levántela NOTA No hale el borde inferior hacia usted más de 3 o podría dañar las lengüetas de la rejilla Remueva el tornillo de cada lado de la caja Manténgalos en un lugar seguro Deslice el acondicionador de aire de la caja agarrando la manija del recipiente de la base y halando hacia el frente m...

Page 31: ...do del compresor 4 B 11 Instrucciones para la instalación Retire y deseche la almohadilla de empaque INSTALE EL RIELE DE MONTAJE SUPERIOR EN LA CAJA Retire el refuerzo de la cinta de sellado del riel de montaje superior y únala a la parte inferior del riel de montaje superior 5 A Cinta de sellado Riel de montaje superior Parte inferior Tornillos tipos A Riel de montaje superior ...

Page 32: ...ón a la caja usando 4 tornillos tipos A en cada lado 6 A B Tornillos tipos A Riel de montaje superior Riel de montaje inferior Panel de acordeón PREPARE LA VENTANA Corte el sello del marco de la ventana a lo ancho de ésta y pegue la cinta adhesiva en la parte inferior del marco 7 Sello del marco de la ventana 12 Instrucciones para la instalación POSTERIOR INTERIOR ...

Page 33: ...ás alejado en el umbral Una los soportes del umbral al agujero de trayectoria de la caja en relación con la posición seleccionada usando dos tornillos tipo A en cada soporte 8 Tornillo Tuerca Soporte del umbral EXTERIOR INTERIOR INSTALE LA CAJA EN LA VENTANA CONT Ajuste el tornillo y la tuerca en cada soporte de forma tal que la caja esté instalada con una inclinación ligera hacia el exterior Use ...

Page 34: ...tale el filtro Conecte la energía eléctrica ASEGURE LA CAJA EN LA VENTANA E INSTALE EL EMPAQUE SUPERIOR DE ESPUMA DE LA VENTANA Pegue el soporte de cierre de la ventana con un tornillo tipo B Corte el empaque superior de espuma de la ventana al ancho de la ventana Rellene la espuma entre el vidrio y la ventana para evitar que el aire y los insectos entren al cuarto A B C Instrucciones para la inst...

Page 35: ...ción podría haber Cuando el acondicionador de aire se enciende usted estado caliente necesita darle tiempo para que enfrié la habitación El aire frío se está escapando Cerciórese de que los registros de la calefacción no están abiertos y se encuentran retornando el aire frío Las bobinas de enfriamiento Ver Acondicionador de aire congelándose más adelante se congelaron El acondicionador de aire El ...

Page 36: ... la eficiencia Quizás escuche que el termostato hace clic cuando el compresor hace ciclo entre encendido y apagado El agua se acumula en la bandeja durante días lluviosos o con mucha humedad El agua podría derramarse y gotear desde el lado externo de la unidad El ventilador podría funcionar aun si el compresor no lo hace Apoyo al consumidor Solucionar problemas Operación Seguridad Instalación 16 A...

Page 37: ...Notas www GEAppliances com 17 Apoyo al consumidor Solucionar problemas Operación Seguridad Instalación ...

Page 38: ...18 Apoyo al consumidor Solucionar problemas Operación Seguridad Instalación Notas ...

Page 39: ...de obra necesaria para retirar la unidad hacia un lugar para revisión por parte de un técnico individual Reemplazo de fusibles de la casa o reajuste del sistema de circuitos Fallos debido a la corrosión en modelos que no están protegidos contra la corrosión Daño al producto causado por voltaje inapropiado hacia el equipo accidentes incendios inundaciones o actos de la naturaleza de fuerza mayor Da...

Page 40: ...a detalles sobre descuentos especiales disponibles mientras su garantía está aún activa Puede comprarla en línea en cualquier momento o llamar al 800 626 2224 durante horas normales de oficina GE Consumer Home Services estará aún ahí cuando su garantía termine Piezas y accesorios www GEAppliances com Aquellos individuos con la calificación necesaria para reparar sus propios electrodomésticos puede...