background image

Safety Instructions

  .  .  .  .  .  .  .  .  .  .  .  . 2, 3

Operating Instructions

  .  .  .  .  .  .  .  .  . 4, 5

Care and Cleaning

Air Filter   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6

Outdoor Coils  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6

Installation Instructions

  .  .  .  .  .7–10

Troubleshooting Tips

  .  .  .  .  .  .  .  .  .  .  . 11

Normal Operating Sounds  .  .  .  .  .  .  .  .  .  .  . 11

Consumer Support

Consumer Support  .  .  .  .  .  .  .  .  .  .Back Cover

Ownership Registration for 

Customers in Canada only  .  .  .  .  .  .  .  .13, 14

Warranty for Customers 

in Canada   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 16

Warranty for Customers 

in the U .S .A .

  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 15

49-7700

     03-12 GE  

AEG10*

Owner’s Manual and 

Installation Instructions

Write the model and serial numbers here:

Model #  _________________________

Serial # __________________________

Find these numbers on a label on the side of 

the air conditioner .

A

ir 

Co

nd

iti

on

er

s

GEAppliances .com

Ro

om

As an 

E

nErgy

 S

tar

®

 partner, GE has 

determined that this product meets  

the 

E

nErgy

 S

tar

®

 guidelines for 

energy efficiency .

*

E

nErgy

 S

tar

®

 labeled product

Climatiseur

Acondicionador  

de aire

Manuel d’utilisation et 

instructions d’installation

Manual del propietario 

e instrucciones de 

instalación

La section française commence à la page 17

La sección en español empieza en la página 35

In Canada, contact us at: 

www .GEAppliances .ca

Summary of Contents for AEG10 series

Page 1: ...ite the model and serial numbers here Model _ _________________________ Serial ___________________________ Find these numbers on a label on the side of the air conditioner Air Conditioners GEAppliances com Room As an Energy Star partner GE has determined that this product meets the Energy Star guidelines for energy efficiency Energy Star labeled product Climatiseur Acondicionador de aire Manuel d ...

Page 2: ...ified electrician n These R410A air conditioning systems require contractors and technicians to use tools equipment and safety standards approved for use with this refrigerant DO NOT use equipment certified for R22 refrigerant only SAFETY PRECAUTIONS Do not under any circumstances cut or remove the third ground prong from the power cord For personal safety this appliance must be properly grounded ...

Page 3: ... reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful...

Page 4: ...e the Auto pad to turn Auto fan on Mode Pad Use to set the air conditioner to Cool Energy Saver or Fan Only mode Delay Pads Delay 1 24hr Pad Delay ON When the air conditioner is off it can be set to automatically come on in 1 to 24 hours at its previous mode and fan settings Delay OFF When the air conditioner is on it can be set to automatically turn off in 1 to 24 hours How to set Press the Delay...

Page 5: ...h a middle set temperature Energy Saver Mode Power Consumption Reduction Mode on Automatically turns on after receiving the DRLC PRICE command from Server The compressor will cycle on and off or fully off based on the reduction ratio Mode off Automatically turns off at the expiration of given duration or after receiving STOP CANCEL command from Server Fan Only Mode Use the Fan Only Mode at Low Med...

Page 6: ...ng it back into position NOTES n Use 2 AAA 1 5 volt alkaline batteries Do not use rechargeable batteries n Remove the batteries from the remote control if the system is not going to be used for a long time n Do not mix old and new batteries Do not mix alkaline standard carbon zinc or rechargeable ni cad ni mh etc batteries How to Insert the Batteries in the Remote Control Air Filter The air filter...

Page 7: ...imizes the possibility of electric shock hazard If the wall outlet you plan to use is only a 2 prong outlet it is your responsibility to have it replaced with a properly grounded 3 prong wall outlet Some models require 230 208 volt AC protected with a time delay fuse or circuit breaker These models should be installed on their own single branch circuit for best performance and to prevent overloadi...

Page 8: ...lation Instructions Right accordion panel Foam top window gasket Left accordion panel Screw 6 Window sash seal Air conditioner Window locking bracket 1 PARTS INCLUDED Appearance may vary Frame locking bracket 2 ...

Page 9: ...panels if needed to fit in a narrow window See the window opening dimensions All supporting parts must be secured to firm wood masonry or metal The electrical outlet must be within reach of the power cord 1 PREPARE THE AIR CONDITIONER Hold the accordion panel in one hand and gently pull back to free the open end Slide the free end of the accordion panel into the side panel rails Slide the panel do...

Page 10: ...rly constructed windows attach the window locking bracket to the window side jamb with one screw B C Wood Vinyl 3 Screws C 10 INSTALL THE AIR CONDITIONER IN THE WINDOW Place the air conditioner on the sill with the bottom mounting rail against its back edge Center it and close the window securely behind the top mounting rail It should be level or slightly tilted to the outside Use a level about a ...

Page 11: ... Make sure there are no curtains blinds or furniture not cool as it should blocking the front of the air conditioner The temp control may On models with touch pads In the Cool mode press the not be set correctly Decrease pad On models with control knobs turn the temperature knob to a higher number The air filter is dirty Clean the filter at least every 30 days See the Care and Cleaning section The...

Page 12: ...cted to connected to different network Check the SSID of the router Nucleus is connected to If both SSIDs are different choose SSID of the router that Nucleus is connected to Air Conditioner is turned off Make sure the air conditioner plug is pushed completly into the outlet Make sure the air conditioner is turned on and operating now Nucleus is turned off Make sure Nucleus plug is pushed competel...

Page 13: ...13 Notes ...

Page 14: ...14 Notes ...

Page 15: ... Properly pack your unit We recommend using the original carton and packing materials n Return the product to the retail location where it was purchased n Include in the package a copy of the sales receipt or other evidence of date of original purchase Also print your name and address and a description of the defect In Order to Make a Warranty Claim During the First 30 Days from the Date of Origin...

Page 16: ...cceeding owner for products purchased in Canada for home use within Canada Some provinces do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from province to province To know what your legal rights are in your province consult your loc...

Reviews: