– 23 –
Load Operation Map
Load
(Relays)
Relay
Microwave
(time cook)
Microwave
(sensor)
Speedcook Oven/Bake
(before
reached
target
temp.)
Oven/Bake
(after
reached
target
temp.)
Warm
(Crisp)
Warm
(Moist)
Ventilation
Cook Top
Upper
Heater,
Ceramic
RY8
o
o
x (a)
o
o
o
o
Upper
Heater,
Halogen
RY3
o
o
x (a)
o
o
o
o
Lower
Heater,
Ceramic
RY9
o
o
x (a)
x (pl8)
x (pl6)
o
o
MAG
RY2
x
x
x (a)
o
o
o
o
Upper
Heater,
Sheath
RY7
o
o
o
x
x
x
x
Oven Lamp RY1
x
x
x
x
x
x
x
Fan Motor,
(for MAG)
RY6
x
x
x
x
x
x
x
Convection
Motor
RY16
x
(after 15min
from start)
x
(after 250sec.
from sensing
point)
x
x
x
x
x
Vent Fan,
High
RY11
I
I
I
I
I
I
I
I
Vent Fan,
Low
RY12
I
I
I
I
I
I
I
I
Vent Fan,
Slow
RY13
o
o
x
o
x
o
o
Damper
Motor
RY10
Open
Open
Close
Close
Close
Open
Close
Cook Top
Lamp, Hi
RY14
I
I
I
I
I
I
I
I
x = Operation o = No operation x(a) = Alternative operation I = Independence
Summary of Contents for Advantium SCA1000
Page 15: ...13 GEA01122 Figure 3 Vent Fan Airflow...
Page 16: ...14 Notes...
Page 17: ...15 Notes...
Page 59: ...57 Schematics and Wiring Diagrams 02 05 2 12 8 2 5 22 5 36 6 B Y 32 G R 7 B W 18 W G 24...
Page 60: ...58 2001...
Page 64: ...62 Illustrated Parts Breakdown...
Page 65: ...63...
Page 66: ...64...
Page 67: ...65...
Page 68: ...66...
Page 72: ...70 Notes...
Page 73: ...71 Notes...
Page 74: ...72...