background image

 

Contents

Adapter Plug

3

Model and Serial Numbers

2

Air Direction

5

Problem Solver

7

Appliance Registration

2

Repair Service

7

Care and Cleaning

6

Safety Instructions

2

Air Filter

6

User Maintenance Instructions 6

Condenser Coils

6

Back Cover

Grilles & Cabinet

6

Control Settings

4

Electrical Requirements

3

Energy-Saving Tips

2

Extension Cords

3

 Center

m

Grounding

3

Models 

 

 
 
 

Summary of Contents for ACD09L

Page 1: ... 7 Care and Cleaning 6 Safety Instructions 2 Air Filter 6 User Maintenance Instructions 6 Condenser Coils 6 Warrantv Back Cover Grilles Cabinet 6 Control Settings 4 Electrical Requirements 3 Energy Saving Tips 2 Extension Cords 3 GEAmwer Centerm Grounding 3 80 6262000 Models ACD09L ACD21D ACD14A ACS15D ACD15D ACS18D ACD18D ACS24D GEAppiances ...

Page 2: ...ions before it is used See grounding instructions on page 3 Never unplug your air conditioner by pulling on the power cord Always grip plug firmly and pull straight out from the receptacle Repair or replace immediately all eleetric service cords that have beeome frayed or otherwise damaged Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector en...

Page 3: ...r cord from the adapter always hold the adapter with one hand If this is not done the adapter ground terminal is very likely to break with repeati use Should the adapter ground terminal break DO N USE the appliance until a proper ground has again been established personal responsibility and bligation to have it replaced with a properly Whether your air conditioner is a grounded three prong wall ou...

Page 4: ...ORM ENERGY SAVER SAVE D I i conditioner starts immediately and operates continuously if the Selector Switch is at any setting other than OFF When used with the Delay Start Stop Switch the Timer Control turns the air conditioner on or off at preset times To delay the stirt of the air conditioner anywhere from 1 to hours 1 Set the Timer Control for the number of hours you want to delay the start of ...

Page 5: ...AIR OUT buttons are in the out position 4 Set the Energy Saver Switch at the NORM position For quieter operation 1 Set the Selector Switch at LOW COOL position 2 Turn the Thermostat Control to the desired number When the Thermostat Control is set on 9 or 10 and the Fan is set on low speed moisture may freeze on the coils and prevent the unit from cooling If this happens set the Fan at high speed a...

Page 6: ...r behind the front grille should be checked and cleaned at least every 30 days or as often as it needs cleaning To remove the filter Air Inlet Grille Removal If your air conditioner is mounted flush inside the room or if the window sill extends farther into the room than the chassis it maybe necessary to remove the air inlet grille before the filter can be removed To remove the grille pull the air...

Page 7: ...n runs continuously when Selector Switch is in Cool or Fan position This is normal When Energy Saver Switch is set at SAVE fan cycles on and off with compressor WATER DRIPPING Excess water may overflow in extremely hot and humid weather This is normal OUTSIDE WATER DRIPPING Air conditioner must be installed level or tilted slightly to the outside for proper INSIDE water disposal WATER IN BASE PAN ...

Page 8: ...ICE WHAT IS NOT COVERED Service trips to teach you how to Improper installation Failure of the product resulting from use the product If you have an installation modifications to the product or due to Read your Use and Care material problem or if the air conditioner unreasonable use including failure to If you then have any questions is of improper cooling capacity provide reasonable and necessary...

Reviews: