For example, during a sensor test you normally expect to hear up 
to eight data rounds. Because the power saving feature is on, you 
may only hear up to four data rounds.

To ensure a sensor is within range of a panel, leave the sensor in 
the closed (non-alarm) condition for five minutes prior to trip-
ping it. This allows the sensor to disengage the power-saving 
feature and provides for more accurate test results.

Battery Replacement

When the system indicates a low sensor battery, immediately 
replace the battery. Use only exact replacement batteries (see 

Specifications

).

1.

Remove sensor cover.

2.

Remove battery and dispose as required by local laws.

3.

Insert replacement battery. Observe polarity (see Figure 4).

4.

Perform sensor test.

Figure 4.

Observing Battery Polarity

Specifications

Notices

This device complies with FCC Rules Part 15. Operation is subject to the 
following two conditions:

1. This device may not cause harmful interference.
2. This device must accept any interference that may be received, 

including interference that may cause undesired operation.

Changes or modifications not expressly approved by GE Security can 
void the user’s authority to operate the equipment.
FCC ID: B4Z-503A-DWS

Positive Terminal

Model No.

60-362: Door/Window Sensor
60-641: Long Life Door/Window Sensor

Compatibility

All GE Security 319.5 MHz Learn Mode panels

Power Source

60-362: 1/2 AA 3.6V Saft or Tekcell Lithium Battery
60-641: AA 3.6V Lithium Battery

Storage Temperature

-30° to 140°F (-34° to 60°C)

Operating Temperature

10° to 120°F (-12° to 49°C)

Maximum Humidity

90%, non-condensing

Transmit Range

Minimum of 500 feet in open-air

UL Listings

UL 1023 – Household Burglar Alarm Units

 

                   and Systems

                      GE Security
       1275 Red Fox Road
 Arden Hills, MN 55112

Technical Support
T: 800.777.2624
F: 651.779.4890

www.gesecurity.com