background image

10

11

RAK201 

(AZC and AZ Series*)

  

Access Plate Cover

The RAK201 access plate cover is made of heavy-gauge steel 
with multiple knockouts for special applications. Will adapt to 
service conduit .875" or 1.125"; circuit breaker up to 0 amp or 
0 amp receptacle. The RAK201 fits old sub-bases RAK120, 
RAK121 and RAK122 for easy replacement of A-B series with 
AZC and AZ series.

RAK7022 

(AZ Series*—2200, 2500, 2800, 200,  

500 and 800 only)

 Duct Transition for Replacement  

of AZC with Rounded Front AZ Chassis 

The RAK7022 duct transition is designed to allow duct installation where 
the original chassis was a slope front discharge (AZC/AZR/AZ21/AZ1) 
chassis. Using the RAK7022 will allow the existing duct adapter and 
extension to be used without requiring the relocation of the hole through 
the wall to the adjacent room.

RAK204 

(AZ Series*—2200, 2500, 200 and 500 only)

 

Standard Sub-Base

The RAK204 sub-base is made of heavy-gauge steel to provide support of the 
wall case. It has full base enclosure with break-away side channels, simple 
connection to wall case, and 4-point leveling legs. The sub-base will adapt to 
service conduit, circuit breakers and receptacles up to 0 amps. It may also be 
used as a non-electrical sub-base to provide support for the unit.
   

 

Circuit

 

Kit No. 

Sub-Base 

Ampacity 

Chaseway 

Power Cord

RAK204U** 

Standard 

N/A 

Not Included 

Not Included

RAK204D20 

Sub-Base 20/208V 

15 & 20  

Included 

Not Included

RAK204D0 

Sub-Base 20/208V 

Included 

Not Included

RAK204E15 

Sub-Base 265/277V 

15 

Included 

Not Included

RAK204E20 

Sub-Base 265/277V 

20 

Included 

Not Included

RAK204E0 

Sub-Base 265/277V 

Included 

Not Included

Power cord and junction box 
not included with sub-base.

Chaseway

A-B Series:

 Zonelines built before 1987 – Zoneline 

I, II, III, 

and 

IV; AZC Series:

 Zonelines built from 1987 to 1992 – includes AZR Series – Zoneline 1000, 2000, 2500, 2700, 000, 

4000, 5000; 

AZ Series:

 Zonelines built after 1992 – Zoneline 2100, 100, 2600, 5100 / Zoneline 2200, 200, 5200 / Zoneline 2500, 500, 5500 / Zoneline 2800, 800, 5800.

Zoneline

®

 units

Zoneline units

RAK205CW  

(AZ Series*—2200, 2500, 2800, 200, 500, 800, 5200, 5500  
and 5800 only)

  

Chaseway

Chaseway for wiring containment between junction box on  
chassis and RAK204U sub-base.

RAK702 

(AZ Series*—2100 and 100 only)

 

Duct Transition for Replacement of  

AZC with Sloped Front AZ Chassis

The RAK702 duct transition is designed to allow duct installation 
where the original chassis was a slope front discharge (AZC or 
AZR) chassis. Using the RAK702 will allow the existing duct 
adapter and extension to be used without requiring the 
relocation of the hole through the wall to the adjacent room.

RAK7012 

(AZ Series*—2200, 2500, 200, 500,  

2800 and 800 only) 

Duct Adapter for Replacement of  

A-B with Rounded Front AZ Chassis

The RAK7012 duct adapter is designed to line up with the duct 
extension where the original chassis was a flat-top discharge  
A-B Series. Using the RAK7012 will allow the existing duct 
extension to be used without requiring the relocation of the hole 
through the wall to the adjacent room. Discharge grille, end 
plate, and extension mounting hardware must be removed from 
old duct adapter and installed on the RAK7012.

8-/8"

6-1/2"

Chaseway

RAK204 

(AZ Series*—2800, 800, 5200, 5500 and 5800 only)

 

Standard Sub-Base

The RAK204 sub-base is made of heavy-gauge steel to provide support  
of the wall case. It has full base enclosure with break-away side channels, simple 
connection to wall case, and 4-point leveling legs. The sub-base will adapt to 
service conduit, circuit breakers and receptacles up to 0 amps. It may also be 
used as a non-electrical sub-base to provide support for the unit.
   

 

Circuit

 

Kit No. 

Sub-Base 

Ampacity 

Chaseway 

Power Cord

RAK204D15P  Sub-Base 20/208V 

15 

Included 

Included

RAK204D20P  Sub-Base 20/208V 

20  

Included 

Included

RAK204D0P  Sub-Base 20/208V 

Included 

Included

RAK5157/5207/5307

  

(AZ Series*—2800, 800, 5500 & 5800 only)

  

265/277-Volt Universal Power Supply Kit

•  9-pin connector with three 7" 12-gauge conductor wires.

   

 

 

Circuit 

Kit No. 

Volts 

Heater Wattage  Ampacity

RAK5157 

265/277 

2.55 kw 

15

RAK5207 

265/277 

.45 kw 

20

RAK507 

265/277 

5.00 kw 

0

A-B Series:

 Zonelines built before 1987 – Zoneline 

I, II, III, 

and 

IV; AZC Series:

 Zonelines built from 1987 to 1992 – includes AZR Series – Zoneline 1000, 2000, 2500, 2700, 000, 

4000, 5000; 

AZ Series:

 Zonelines built after 1992 – Zoneline 2100, 100, 2600, 5100 / Zoneline 2200, 200, 5200 / Zoneline 2500, 500, 5500 / Zoneline 2800/800/5800.

**RAK204U May be used with AZC and AZ 2100, 100, 2600 and 5100.

†The power connection kit determines the heater wattage and current requirements when it is plugged into the Zoneline unit. NOTE: All power cord kits and permanent 

connection kits may be used on all units (of matching voltage). NOTE: 7,000 BTU models do not have 5,000 watt heaters.

Summary of Contents for 49218

Page 1: ...GE airconditioner accessories Vertical Zoneline Zoneline Built in models ...

Page 2: ... Vertical Zoneline units ...

Page 3: ...00 AZ Series Zonelines built after 1992 Zoneline 2100 3100 2600 5100 Zoneline 2200 3200 5200 Zoneline 2500 3500 5500 Zoneline 2800 3800 5800 RAVWP6 AZ Series 7500 Wall Plenum Wall Plenum for installation in walls less than 6 thick Wall Plenum 19 3 4 x 32 Wall cutout dimensions 20 x 32 1 4 Warm gray beige color RAVWP8 AZ Series 7500 Wall Plenum Wall Plenum for installation in walls less than 8 thic...

Page 4: ... Aluminum Outdoor Grille for installation on RAVWP series wall plenums Grille is 19 3 4 x 32 x 1 1 4 Mill finish A B Series Zonelines built before 1987 Zoneline I II III and IV AZC Series Zonelines built from 1987 to 1992 includes AZR Series Zoneline 1000 2000 2500 2700 3000 4000 5000 AZ Series Zonelines built after 1992 Zoneline 2100 3100 2600 5100 Zoneline 2200 3200 5200 Zoneline 2500 3500 5500 ...

Page 5: ... Ampacity RAK5157 265 277 2 55 kw 15 RAK5207 265 277 3 45 kw 20 RAK5307 265 277 5 00 kw 30 RAK3152 3202 3302 AZ Series 5100 5200 5500 and 7500 only 15 20 and 30 Amp 230 208 Volts Universal Power Supply Circuit Kit No Volts Heater Wattage Ampacity RAK3152 230 208 2 550 2 090 15 RAK3202 230 208 3 450 2 820 20 RAK3302 230 208 5 000 4 090 30 A B Series Zonelines built before 1987 Zoneline I II III and...

Page 6: ... Zoneline units ...

Page 7: ...re 1 2 O D copper and consist of a short right angle tube and a 6 long straight tube to suit the particular application RAF452 AZ Series 2200 3200 and 5200 only Replacement Standard Room Cabinet Room cabinet with wrap around design has attractive textured finish which matches unit sleeve Cabinet is injection molded of high impact polystyrene Cabinet fastens to chassis without tools or hardware The...

Page 8: ... Zoneline 2100 3100 2600 5100 Zoneline 2200 3200 5200 Zoneline 2500 3500 5500 Zoneline 2800 3800 5800 Zoneline units RAG61 62 63 AZ Series Architectural Rear Grille Optional one piece molded grille and frame assembly for improved appearance and protection Grilles are molded of GE Cycoloy and have a slightly textured colorfast surface to blend with most walls RAG61 Beige RAG62 Maple RAG63 Dark Brow...

Page 9: ...ine I II III and IV AZC Series Zonelines built from 1987 to 1992 includes AZR Series Zoneline 1000 2000 2500 2700 3000 4000 5000 AZ Series Zonelines built after 1992 Zoneline 2100 3100 2600 5100 Zoneline 2200 3200 5200 Zoneline 2500 3500 5500 Zoneline 2800 3800 5800 RAK605 AZ Series 2100 and 3100 only Duct Adapter Not for 2600 and 5100 Series The RAK605 duct adapter is attached to the top of the w...

Page 10: ...000 2000 2500 2700 3000 4000 5000 AZ Series Zonelines built after 1992 Zoneline 2100 3100 2600 5100 Zoneline 2200 3200 5200 Zoneline 2500 3500 5500 Zoneline 2800 3800 5800 Zoneline units RAK702 AZ Series 2100 and 3100 only Duct Transition for Replacement of AZC with Sloped Front AZ Chassis The RAK702 duct transition is designed to allow duct installation where the original chassis was a slope fron...

Page 11: ...case It has full base enclosure with break away side channels simple connection to wall case and 4 point leveling legs The sub base will adapt to service conduit circuit breakers and receptacles up to 30 amps It may also be used as a non electrical sub base to provide support for the unit Circuit Kit No Sub Base Ampacity Chaseway Power Cord RAK204D15P Sub Base 230 208V 15 Included Included RAK204D...

Page 12: ...277 volt units RAK4002 AZ Series 2200 3200 and 5200 only Direct Connect Junction Box 230 208 and 265 277 Volts RAK4002 junction box kit for permanent connection of 230 208 and 265 277 volt units to building power supply Includes multi circuit connector harness for use on value line units Junction box is included on 265 277 volt units RAK3153 3203 3303 AZ Series 2800 3800 5500 and 5800 only 15 20 a...

Page 13: ...is included on 265 277 volt units RAK8022 AZ Series 2200 2500 3200 3500 5200 and 5500 only Locking Door Kit The RAK8022 provides door lock kit and key to prevent access to Zoneline unit controls Also provides two thumb screws for securing the room cabinet to the chassis on the lower right and left sides RAK5172 5202 5302 AZ Series 2800 3800 5500 and 5800 only 15 20 and 30 Amp 265 277 Volts Univers...

Page 14: ...he up front filters on the GE Zoneline unit are conveniently accessed by simply pulling them up from the top of the room cabinet By simplifying the task filter cleaning is more likely to occur on schedule and the unit will operate as efficiently as possible Sold in pairs RAK806 Universal Cover Label 10 covers per kit The RAK806 provides a cover for the control area to refer room occupant to use a ...

Page 15: ...15 Built in units ...

Page 16: ...he unit RAB47 48 Tenant Option Wall Cases for J Chassis When the air conditioner is offered as a tenant option these wall cases provide protection against outside elements RAB47 includes wall case exterior grille weather panel and steel closure panel RAB48 includes wall case exterior grille insulated steel indoor closure panel and insulated outdoor panel RAB46 Standard Wall Case for J Chassis Buil...

Page 17: ...uminum Exterior Grille J Series Used to replace exterior grille on old J wall case to maximize efficiency and capacity of new chassis The grille is included with new wall cases RAB46 47 or 48 RAF622A Replacement Room Front for Rounded Front J Chassis Replacement Room Front for J series chassis with Oval Control Knob opening Not for use on High Mount Models RAK690 Architectural Louver Grille Adapte...

Page 18: ...eve Adapter Kit adapts Fedders A wall case for installation of the J wall case includes outdoor grille and J model chassis Existing Fedders wall case dimensions are 27 W 16 3 4 H 16 3 4 D Kit consists of four gaskets which are applied to the wall case to assure a tight weather seal between the two cases RAK1072 Hotpoint Chassis Sleeve Adapter Kit adapts Hotpoint ACXB 10 and ACXB 11 wall case used ...

Page 19: ... Washable reusable nylon mesh filter Order individually or by box of 20 Used for Standard or High Mount models RAA72A Replacement Filter for Rounded Front J Chassis Replacement filter for use in Room Fronts with Oval Control Knob openings ONLY Washable reusable nylon mesh filter Order individually or by box of 20 Used for Standard or High Mount models ...

Page 20: ...tat 24V AC digital remote wall thermostat with Single Stage Cooling and 2 Stage Heating for heat pump models Requires 6 wire hook up RAK148P1 A B AZ 3500 3800 5500 5800 7500 and AZR Series Heat Pump Programmable Remote Thermostat 24V AC programmable remote wall thermostat with Single Stage Cooling and 2 Stage Heating for heat pump models Programmable for 7 day or 5 2 day programs Requires 6 wire h...

Page 21: ... Thermostat 24V AC programmable remote wall thermostat with Single Stage Cooling and Single Stage Heating for resistance heat models Programmable for 7 day or 5 2 day programs Requires 5 wire hook up RAK164D1 A B AZ 2500 2800 7500 and AZR Series Cooling with Electric Heat Digital Remote Thermostat 24V AC digital remote wall thermostat with Single Stage Cooling and Single Stage Heating for resistan...

Page 22: ...sk control or remote thermostat control for 2200 3200 5200 only AZ 8 RAK40 Air deflector kit AZ 9 RAK4002 Direct connect junction box 230 208 and 265 277V for 2200 3200 5200 only AZ 12 RAK4002A 230 208V direct connect junction box for 2500 3500 2800 3800 only AZ 12 RAK4002B 230 208V direct connect junction box for 5500 5800 only AZ 13 RAK4002CW 230 208V and 265 277 direct connect junction box wiri...

Page 23: ...pool is a registered trademark of Whirlpool U S A Number Description Page No RAA72 Replacement filter for rounded front J chassis 2 round control knob openings 19 RAA72A Replacement filter for rounded front J chassis oval control openings 19 RAB46 Standard wall case for J chassis built in unit 16 RAB47 Tenant option wall case for J chassis 16 RAB48 Tenant option wall case for J chassis 16 RAK66 Wa...

Page 24: ...by providing answers on product features 800 626 2000 ge com features installation instructions models use care manuals specifications warranty Quick Specs Product features and dimensions are faxed to you FREE wherever and whenever you need them 800 432 3729 A nationwide network of sales professionals and service technicians wholly dedicated to the builder community 800 GE CARES 800 432 2737 GECus...

Reviews: