Install an approved junction box where it
can be easily reached through the front of
the cabinet where the cooktop will be
located. 

The cooktop conduit is 3 feet long.

IMPORTANT: The junction box
must be located where it will allow
considerable slack in the conduit
for serviceability.

Place a towel or tablecloth onto the
countertop. Lay the cooktop upside down
onto the protected surface.

5

Install junction box 

so that it can be reached 

through the front of 

the cabinet.

16" 

Min.

Installing
the
Junction
Box

Protect
Surface of
Cooktop

(Continued on following page)

Bottom of cooktop

Cloth under Cooktop

Installation

Electronic Radiant Cooktop

!

Five inches (5

) minimum vertical clearance between

the cooktop bottom and any combustible surfaces.

Vertical
Clearance

To insure accuracy, it is best to make a
template when cutting the opening in the
counter.  Make sure there is clearance
inside the cabinet before cutting the
countertop.

Make sure the wall coverings, countertop and
cabinets around the cooktop can withstand heat
(up to 200°F) generated by the cooktop.

Cutout
Dimensions
of the
Countertop

Wall
Coverings,
Countertop
& Cabinets

5"Min.

 Vertical Clearance

1 3/4" Min.

Between cutout 

and the wall behind 

the cooktop

19 1/8" width of cut

33 7/8"

length of 

cut

2 1/2"Min. 

from front edge 

of cutout 

and front edge 

of countertop

2 1/2" Min.

Wall covering,
cabinets and
countertop must
withstand heat
up to 200°F.

Summary of Contents for 36 ELECTRIC RADIANT COOKTOP ZEU36R

Page 1: ...GE Monogram Installation Instructions 36 Electric Radiant Cooktop Model ZEU36R Monogram com...

Page 2: ...1845 For Monogram Service in Canada 1 888 880 3030 For Monogram Parts and Accessories call 1 800 626 2002 Make sure the cabinets and wall coverings around the cooktop can withstand the temperatures u...

Page 3: ...preparing the opening When installing your cooktop in your home make sure all local codes and ordinances are followed exactly as stated 3 Make sure the wall coverings countertop and cabinets around t...

Page 4: ...mensions must be maintained Overall Cooktop Dimensions Minimum Clearances 2 MIN clearance from cutout to side wall on the left of the unit 30 MIN clearance from countertop to unprotected overhead surf...

Page 5: ...op Installation Electronic Radiant Cooktop Five inches 5 minimum vertical clearance between the cooktop bottom and any combustible surfaces Vertical Clearance To insure accuracy it is best to make a t...

Page 6: ...DES Installation Electronic Radiant Cooktop Apply the foam strips around the outer edge of the glass Do not overlap the foam strips Attach Foam Strips Foam Strips Bottom of Cooktop Cooktop Glass Remov...

Page 7: ...lead attach the appliance grounding lead green or copper to the residence grounding conductor green or bare copper in accordance with local codes When connecting to a 3 conductor branch circuit if lo...

Page 8: ...ads supplied with this appliance are UL recognized for connections to larger gauge household wiring The insulation of these leads is rated at temperatures much higher than the temperature rating of ho...

Reviews: