background image

 

Specifications and Ordering Information 

Part Number 141500-01 

Rev. J (06/07) 

 

Page 4 of 6 

Ordering Information 

For spares, order the complete catalog number as 
described below.  This includes a front panel 
assembly, monitor PWAs with sheet metal, and 
appropriate relay module.  This unit is optioned, 
tested and ready to install in your system.  Spare 
relay modules can be ordered separately. 

Dual Thrust Position Monitor 

3300/20-AXX-BXX-CXX-DXX-EXX 

Option Descriptions 

A:

  Full-scale Range Option 

0 1

 

25-0-25 mils 

0 2 

30-0-30 mils 

0 3 

40-0-40 mils 

0 5

 

50-0-50 mils 

0 6

 

75-0-75 mils 

1 1 

0.5-0-0.5 mm 

1 2 

1.0-0-1.0 mm 

1 3

 

2.0-0-2.0 mm 

B: 

Transducer Input Option 

0 1 

3300 or 7200 Proximitor® 
systems, 200 mV/mil (Ranges 
01, 02, 03, 11, and 12 only.) 

0 2 

7200 11 mm (not 3300XL) 
Proximitor system, 100 mV/mil 

0 3 

7200 14 mm or 3300 HTPS 
Proximitor systems, 100 
mV/mil 

0 4

 

3000 Proximitor® 200 mV/mil 
(Transducer Output Voltage in 
power supply must be set for –
18 Vdc or use power conver-
ter.  Ranges 01 and 11 only.) 

0 5 

3300XL NSv and 3300 RAM 
Proximitor Sensor, 200 mV/mil 
(Ranges 01 and 11 only). 

Note:  

1. 

For 3300 XL 11mm transducers, use mod 146300-01. 

2. 

Contact your nearest  sales professional if 3000 series 
transducers are to be used in a monitoring system 
which also uses 3300 and/or 7200 Series transducers. 

C:

  Alarm Relay  Option 

0 0

 

No Relays 

0 1 

Epoxy-sealed 

0 2 

Hermetically-sealed 

0 3 

Quad Relay (Epoxy-sealed 
only) 

0 4 

Spare Monitor-No SIM/SIRM 

Notes:  

1. 

AND voting logic is not available with Quad Relays. 

2. 

At least one relay module must be ordered with each 
3300 System. If one common relay module per system 
has been ordered, all monitors of this type must be 
jumper programmed at the factory to activate a relay 
bus.  Order SCK (Special Configuration Kit) 157520-119 
& -120 for bus one or 157520-121 & -122 for bus two. 

3. 

Agency approval places limitations on the relay 
module. Refer to the Relay Module data sheet for 
information. 

4. 

Quad Relays are not available with the Internal Safety 
Barriers option. 

D: 

Agency Approval  Option 

0 0 

Not required 

0 1 

CSA/NRTL/C 

0 2 

ATEX self certification 

Note:

 ATEX approval requires the monitor rack be installed in a 

weatherproof housing. 

E:

  Safety Barrier Option 

0 0

 

None 

0 1

 

External 

0 2

 

Internal 

Spare Relay Module Assemblies 

(Order the option in parenthesis for ATEX approved 
spares) 

81544-01(02) 

No Relays 

81545-01(02) 

Dual Epoxy Relays 

81546-01(02) 

Dual Hermetic Relays 

84152-01(02) 

Quad Relays 

88984-01(04) 

Dual Hermetic, Internal Barriers 

88984-02(05) 

Dual Epoxy, Internal Barriers 

88984-03(06) 

No Relay, Internal Barriers

 

Notes: 

1. 

External Safety Barriers must be ordered separately. 

Summary of Contents for 3300

Page 1: ... gap voltage of the proximity probe used as an input a transducer failure gap out of range can be interpreted by the monitor as thrust position movement and result in a false thrust alarm For this reason Bently Nevada LLC does not recommend the use of a single probe for thrust position applications Instead these applications should use two proximity probes observing the same collar or shaft and co...

Page 2: ...Vdc 1 1 of signal 10 mV offset 0 to 10 Vdc 1 1 of signal 15 mV offset Output Impedance voltage outputs 100 Ω Minimum load resistance is 10 k Ω Voltage Compliance current outputs 0 to 12 Vdc range across load Load resistance is 0 to 600 Ω when using 4 to 20 mA option Buffered Transducer Outputs There is one coaxial connector per channel on the front panel and one terminal connection per channel on ...

Page 3: ...status individually for Alert and Danger Flashing alarm LED indicates First Out independent for Alert and Danger Bypass Two red LEDs indicate status of Danger Bypass and Rack Channel Bypass functions individually per channel Environmental Limits Operating Temperature 0 C to 65 C 32 F to 150 F Storage Temperature 40 C to 85 C 40 F to 185 F Relative Humidity To 95 noncondensing CE Mark Directives EM...

Page 4: ...e to be used in a monitoring system which also uses 3300 and or 7200 Series transducers C Alarm Relay Option 0 0 No Relays 0 1 Epoxy sealed 0 2 Hermetically sealed 0 3 Quad Relay Epoxy sealed only 0 4 Spare Monitor No SIM SIRM Notes 1 AND voting logic is not available with Quad Relays 2 At least one relay module must be ordered with each 3300 System If one common relay module per system has been o...

Page 5: ...Latching Nonlatching Danger Reset Mode Option Latching Nonlatching Alert Relay Mode Option Normally de energized Normally energized Danger Relay Mode Option Normally de energized Normally energized Recorder Outputs Option 4 to 20 mA 1 to 5 Vdc 0 to 10 Vdc Danger Relay Voting Option AND voting for relay drive OR voting for relay drive Note For Quad Relays AND voting logic must be done externally by...

Page 6: ...WR COM IN BUF REC NC ARM NO NC NO ARM Channel A Channel B To Channel A Recorder To Channel B Recorder Output Alert Relay Danger Relay Contacts Dual Relays Shown Quad Relays also available 3 Conductor Proximitor Channel B Channel A Shaft Thrust Collar BUFFERED TRANSDUCERS DANGER A A B B GAP ALERT BYPASS ALERT 5 5 L DANGER OK 25 0 25 20 T N 15 E R 4 10 E M E C A O U N T C 8 20 15 10 I P S D 0 12 L S...