background image

Summary of Contents for 31-16223

Page 1: ...ns for local inspector s use Before the old dryer is removed from service or discarded remove the dryer door inspect the dryer exhaust outlet and straighten the outlet walls if they are bent Service information and the wiring diagram are located in the control console Do not allow children on or in the appliance Close supervision is necessary when the appliance is used near children install the dr...

Page 2: ...ury STEP 1 Attach two chains using Phillips head screws to each end of upper unit cabinet STEP 2 Locate two wall studs behind desired operating location of stacked units NOTE For wall studs not appropriately spaced see section for Alternate Method for Installation of Wall Hooks STEP 3 Screw two wall hooks into two wall studs same height as chain connections on cabinet of upper unit Both chains sho...

Page 3: ...ion must conform to local codes and ordinances or in their absence the NATIONAL FUEL GAS CODE ANSI Z223 This gas dryer is equipped with a Valve Burner Assembly for use only with natural gas Using conversion kit WE25X0217 your local service organization can convert this dryer for use with propane LP gas ALL CONVERSIONS MUST BE MADE BY PROPERLY TRAINED AND QUALIFIED PERSONNEL AND IN ACCORDANCE WITH ...

Page 4: ...rs as shown Connector nuts must not be connected directly to pipe threads APPLYPIPECOMPOUND TO THEADAPTERAND DRYER GAS INLET Tighten the flexible gas line using two adjustable wrenches INFORMATION continued APPLYPiPECOMPOUND TOALL MALETHREADS Tighten all connections using two adjustable wrenches Do not overtorque gas connections LEAKTEST A_ WARNING NEVERUSEAN OPEN FLAMETOTEST FORGAS LEAKS OPEN GAS...

Page 5: ...H The MAXIMUM ALLOWABLE duct length and number of bends of the exhaust system depends upon the type of duct number of turns the type of exhaust hood wall cap and all conditions note below The maximum allowable length for rigid metal duct is shown in the table below More than two 90 turns is not recommended The total length of flexible metal duct shall not exceed 8 ft 2 4 m In Canada and in the Uni...

Page 6: ...ecure the duct in place through the tab on the appliance base Use standard metal elbows and duct to complete exhaust system Insert standard elbow and ducts through rear and side or bottom openings Cover the opening at the back with the plate Kit WE1 M454 available from your Local Service Provider HOUSING BASE TAB LOCATION 9 CUT UNDER EXHAUST PORTION Only metal duct may be used inside the dryer cab...

Page 7: ...NANCE iNSTRUCTiONS The Drum The drum is rust resistant and requires no special care The Exterior Wipe off any spills or washing compounds Wipe or dust with damp cloth Try not to strike the surface with sharp objects The Lint Filter Wipe lint filter before every use Periodically lint filter should be removed and suction hose from vacuum cleaner should be inserted into the opening Dryer Exhaust Insp...

Reviews: