3-WIRE INSTALLATION

WARNING:

The neutral or ground wire of the power cord must be connected 

to the neutral terminal located in the center of the terminal block. Ground strap must connect
the neutral teminal to the ground plate. The power leads must be connected to the lower 
left and the lower right terminals of the terminal block.

DO NOT remove the ground strap connection.

FOR POWER CORD INSTALLATION

A. 

Remove the 3 lower terminal screws from the terminal block. 

B.

Insert the 3 terminal screws through each power cord termi-
nal ring and into the lower terminals of the terminal block. Be
certain that the center wire (white/neutral) 
is connected to the center lower position of the terminal
block. 

C.

Tighten screws securely into the terminal block.

FOR CONDUIT INSTALLATION

A. 

Loosen the 3 lower terminal screws from the terminal block. 

B. 

Strip wire to expose tip about 5/8" long. Insert the center 
(white/neutral) wire tip through the bottom center terminal block opening. On
certain models, the wire will need to be inserted 
through the ground strap opening and then into the bottom 
center block opening. Insert the two side bare wire tips into 
the lower left and the lower right terminal block openings. 

C. 

Tighten screws until the wire is firmly secured (35 to 50 inch-lbs.). 
Do not over-tighten the screws.

NOTE: ALUMINUM WIRING: 

Aluminum building wire may 

be used but it must be rated for the correct amperage and voltage. 

PROCEED TO STEP 9.

7

Ground
strap

Terminal block
(appearance
may vary)

Neutral 
terminal

Power cord

Ground 
plate

Power Cord

4-WIRE INSTALLATION

WARNING:

The neutral wire of the supply

circuit must be connected to the neutral terminal
located in the lower center of the terminal block.
The power leads must be connected to the lower
left and the lower right terminals of the terminal block. 
The grounding lead must be connected to the frame 
of the range with the ground plate and the green 
ground screw.

FOR POWER CORD INSTALLATION

A. 

Remove the 3 lower terminal screws from 
the terminal block. Remove the ground screw 
and ground plate and retain them.

Cut and discard 

the ground strap. DO NOT DISCARD ANY SCREWS.

B.

Insert the one ground screw into the power cord ground
wire terminal ring, through the ground plate and into 
the frame of the range.

C.

Insert the 3 terminal screws (removed earlier) through 
each power cord terminal ring and into the lower terminals 
of the terminal block. Be certain that the center wire
(white/neutral) is connected to the center lower position 
of the terminal block. Tighten screws securely into 
the terminal block.

FOR CONDUIT INSTALLATION

A.

Loosen the 3 lower terminal screws from the terminal block.
Remove the ground screw and ground plate and retain
them. 

Cut and discard the ground strap. DO NOT

DISCARD ANY SCREWS.

B.

Strip the wire to expose tip about 5/8" long. Insert 
the ground bare wire tip between the range frame 
and the ground plate (removed earlier) and secure 
it in place with the ground screw (removed earlier). 
Insert the bare wire (white/neutral) tip through the bottom 
center of the terminal block opening. Insert the two 
side bare wire tips into the lower left and the lower 
right terminal block openings. 

C.

Tighten the screws until the wire is firmly secured 
(35 to 50 inch-lbs.). Do not over-tighten the screws.

NOTE: ALUMINUM WIRING: 

Aluminum building wire may be used but it must be rated 

for the correct amperage and voltage. 

8

Before–Power Cord and Conduit

Terminal
block

Terminal
block

Neutral termi-
nal

Neutral
terminal

Ground
strap

Ground plate
(grounding to
range)

Ground
screw

Ground strap 

or

After–Conduit

Terminal
block

Ground
plate
(grounding
to range)

Wire
tips

Ground screw

After–Power Cord

REPLACE THE WIRE COVER

Replace wire cover on range back by sliding its left edge under 
the retaining tabs and replace the screws removed earlier. Make sure
that no wires are pinched between cover and range back.

9

POWER CORD AND CONDUIT INSTALLATION (CONT.)

C. For power cord installations only 

(see the next

step if using conduit), assemble the strain relief 
in the hole. Insert the power cord through the strain
relief and tighten. Allow enough slack to easily
attach the cord terminals to the terminal block. 
If tabs are present at the end of the winged 
strain relief, they can be removed for a better fit.

NOTE: Do not install the power cord without a
strain relief. The strain relief bracket MUST be
installed before reinstalling the rear range wiring
cover.

D. For conduit installations only

, purchase a squeeze

connector matching the diameter of your conduit and
assemble it in the hole. Insert the conduit through the
squeeze connector and tighten. Allow enough slack to eas-
ily attach the wires to the terminal block.

NOTE: 

Do not install the conduit without a squeeze con-

nector. 

The squeeze connector MUST be installed

before reinstalling the rear range wiring cover.

6

Power cord

Strain relief

Terminal
block

Bracket

Squeeze connector

Terminal
block

Bracket

Wire
cover

Wire tips

Terminal 
block

Conduit

Conduit

Summary of Contents for 31-10673 09-08 JR

Page 1: ...pe Measure Pliers 1 4 Nut Driver PREPARE THE OPENING FOR INDOOR USE ONLY If the countertop area is not flat excess tension may be applied to the glass cooktop causing breakage and voiding the warranty Make sure the wall covering countertop flooring and cabinets around the range can withstand the heat up to 200 F generated by the range A Allow 30 minimum clearance between surface units and bottom o...

Page 2: ... new construction not existing utilize a 4 conductor connection to an electric range When installing an electric range in new con struction mobile home recreational vehicle or an area where local codes prohibit grounding through the neutral conductor refer to the section on four conductor branch circuit connections Check with your local utilities for electrical codes which apply in your area Failu...

Page 3: ...e terminal block Be certain that the center wire white neutral is connected to the center lower position of the terminal block Tighten screws securely into the terminal block FOR CONDUIT INSTALLATION A Loosen the 3 lower terminal screws from the terminal block Remove the ground screw and ground plate and retain them Cut and discard the ground strap DO NOT DISCARD ANY SCREWS B Strip the wire to exp...

Page 4: ...t Make sure edge of countertop fits flush against the end of Front Control Panel Countertop ANTI TIP DEVICE INSTALLATION To reduce the risk of tipping the range the range must be secured by a properly installed anti tip bracket See installation instructions shipped with the bracket for complete details before attempting to install To check if the bracket is installed and engaged properly remove th...

Reviews: