4

Cabinet Preparation & Wire Routing

The wiring may enter the opening from either  side,

rear or the floor within the shaded area.

The hole must be free of sharp edges. If the cabinet

wall is metal, the hole edge must be covered  with a

bushing.

Cable direct connections may pass through the same

hole as the drain hose and hot water  line, if convenient.

If cabinet  wall is metal, the hole edge must be covered

with a bushing. NOTE: Power  cords with plug must pass

through a separate hole.

Electrical Connection to Dishwasher

Electrical  connection  is on the right  front of dishwasher .

For cable direct connections  the cable must be routed

as shown in Figure  5. Cable  must extend  a minimum of

24" from  the  rear  wall.

The power -supply receptacle for the 

appliance shall be installed in  a cabinet or on a

wall adjacent to the undercounter space in which the

appliance is to be installed.

Figure 5

W ARNING

FOR PERSONAL  SAFETY: Remove house

fuse or open circuit breaker  before

beginning  installation.  Do not use an

extension cord or adapter plug with this

appliance.

PREPARE ELECTRICAL  WIRING

Electrical Requirements

This appliance  must be supplied  with 120V, 60 Hz., and

connected to an individual properly grounded branch

circuit, protected by a 15 or 20 ampere circuit breaker

or time delay fuse.

Wiring must be 2 wire with ground.

If the electrical  supply does not meet the above

requirements, call a licensed electrician before

proceeding.

Grounding Instructions 

– Cable Direct

This appliance  must be connected  to a grounded  metal,

permanent  wiring  system, or an equipment  grounding

conductor  must be run with the circuit conductors  and

be connected  to the equipment  grounding  terminal  or

lead on the appliance.

Grounding Instructions 

– Power  Cord Models

This appliance  must be grounded.  In the event  of a

malfunction or breakdown, grounding will reduce the

risk of electrical  shock by providing  a path  of least

resistance  for electric  current. The plug must be

plugged into an appropriate  outlet that is installed

and grounded in accordance with local codes and

ordinances.

W ARNING

The improper connection  of the

equipment grounding conductor can

result in a risk of electric  shock. Check

with a qualified  electrician  or service

representative  if you are  in doubt that

the appliance  is properly grounded.

White

24"

from Wall

3"

from

Cabinet

Ground

Black

1-1/2" Dia.

Hole (Max.)

Cut a 1-1/2

 

For power cord connections, install a 3-prong ground-ing 

type receptacle.

Max.dia.hole to admit the electrical cable. 

Summary of Contents for 206C1559P148

Page 1: ... Note to Installer Be sure to leave these instructions for the and local inspector Inspector s use Note to Consumer Keep these instructions with your Owner s Manual for future reference Installation of this dishwasher requires basic mechanical andelectrical skills Proper installation is the responsibility of the installer Product failure due to improper installation is not covered under the Dishwa...

Page 2: ...Water line 3 8 min copper Coupler for extending drain line if applicable TOOLS YOU WILL NEED Phillips head screwdriver 5 16 and 1 4 nutdriver 6 Adjustable wrench Level Carpenters square Measuring tape Safety glasses Flashlight Bucket to catch water when flushing the line Gloves For New Installations Only Tubing cutter Drill and appropriate bits Hole saw set Elbow Ferrule and Compression Nut Wire N...

Page 3: ...rdinances require an air gap Will waste tee or disposer connection be less than 18 above the floor Will installation have a drain loop less than 32 above floor If the answer to ANY of the 3 questions above is YES Method 1 MUST be used Otherwise either Method 1 or Method 2 may be used Figure 3 or Figure 4 CAUTION An air gap MUST BE USED if the drain hose is connected to waste tee or disposer lower ...

Page 4: ...upplied with 120V 60Hz and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse Wiring must be 2 wire with ground If the electrical supply does not meet the above requirements call a licensed electrician before proceeding Grounding Instructions Cable Direct This appliance must be connected to a grounded metal permanent wiring...

Page 5: ...120PSI CAUTION Opening the door will cause the dishwasher to tip forward Do not open the door until you are ready to install the dishwasher If it is necessary to open the door hold the top of the dishwasher securely with one hand and hold the door with the other hand Open the door slowly if the door drops when released increase Spring tension If the door closes when released decrease tension Pull ...

Page 6: ......

Page 7: ......

Page 8: ......

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ...er the first fill Check dain lines If leaks are found turn power off at the breaker and correct plumbing as necessary Restore power ater corrections are made See Step 12 Open dishwasher door and make sure most of the water has drained If not check that disposer plug has been removed and or air gap is not plugged See Step 13 Also chek drain line for kinking Run the dishwasher through another fill a...

Reviews: