background image

GE Appliances

Room

Air Conditioners

Pub. No. 49-7389 

JR 10-99

AG_05  – 5,200 BTU models

AG_06  – 6,000 BTU models

Owner’s Manual &

Installation Instructions

www.geappliances.com

3828A30036N

Summary of Contents for 200 BTU

Page 1: ...GE Appliances Room Air Conditioners Pub No 49 7389 JR 10 99 AG_05 5 200 BTU models AG_06 6 000 BTU models Owner s Manual Installation Instructions www geappliances com 3828A30036N ...

Page 2: ...iginal purchase date is needed to obtain service under the warranty Inside you will find many helpful hints on how to use and maintain your air conditioner properly Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner READ THIS MANUAL IF YOU NEED SERVICE You ll find many answers to common problems in the Before You Call For Se...

Page 3: ...s in the vicinity of this or any other appliance SAFETY PRECAUTIONS 3 Customer Service Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Do not under any circumstances cut or remove the third ground prong from the power cord For personal safety this appliance must be properly grounded The power cord of this appliance is equipped with a 3 prong grounding plug...

Page 4: ...rary connection may be made to a properly grounded 2 prong wall outlet by use of a UL listed adapter available at most local hardware stores The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord When disconnecting the power cord from the adapter always hold the adapter in place with one hand while pulli...

Page 5: ...MED COOL with the temp control at midpoint For Maximum Cooling Select HI COOL with the temp control at the highest number available on your knob For Quieter Nighttime Cooling Select LO COOL with the temp control at midpoint Temp Control The temp control is used to maintain the room temperature The compressor will cycle on and off to keep the room at the same level of comfort When you turn the knob...

Page 6: ...s About the controls on the air conditioner Additional controls and important information Outdoor Coils The coils on the outdoor side of the air conditioner should be checked regularly If they are clogged with dirt or soot they may be professionally steam cleaned a service available through your GE service outlet Air Filter The air filter behind the front grille should be checked and cleaned at le...

Page 7: ...screw beneath the bottom knob Press in on the lower left side of the case and pull the grille forward Gently press inward on the right side of the case and pull the lower right side of the grille forward to release from the slot Lift the top of the grille up and off to release from the tabs To replace the grille Hook the front of the grille onto the tabs on the top of the case Snap the bottom righ...

Page 8: ...t and circuit checked by a qualified electrician if there is any doubt as to whether a proper ground exists Follow National Electric Codes NEC and or local codes and ordinances CAUTION Do not under any circumstances cut or remove the third ground prong from the power cord Do not change the plug on the power cord of this air conditioner Aluminum house wiring may present special problems consult a q...

Page 9: ...tions Safety Instructions Installation Instructions 9 Window Installation Instructions Parts Included Air conditioner Window sash seal Type A 2 Type B 4 Type C 9 Window locking bracket Foam top window gasket Top mounting rail Support bracket Sliding panels ...

Page 10: ...pening dimensions to the right All supporting parts must be secured to firm wood masonry or metal The electrical outlet must be within reach of the power cord Do not use an extension cord Window opening dimensions are for a standard double hung window 13 min 22 to 36 with sliding panels 18 3 4 min without sliding panels Storm Window Requirements A storm window frame will not allow the air conditio...

Page 11: ... window sash Insert the sliding panels into the guides of the air conditioner and attach them to the case with 8 type C screws 4 on each side Use type C screws B A Install the Support Bracket Open the window and mark the center of the sill Center the support bracket on the mark on the sill against the stool Attach it to the sill with 2 type A screws C B A 3 4 11 Sash Seal Stool Type A screws Outsi...

Page 12: ...iding panels to fill the window opening and use 4 type B screws to secure them 2 on each side C B A 5 12 Customer Service Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructio...

Page 13: ...sket and the Locking Bracket Cut the foam top window gasket to the window width Stuff the foam between the glass and the window to prevent air and insects from getting into the room Seal any air leaks around the air conditioner and the window with gum type sealer Attach the window locking bracket with a type C screw D C B A 6 13 ...

Page 14: ...s and cold air returns Set the air conditioner s vent to the closed position Cooling coils have iced up See freezing up below Air conditioner Ice blocks the air flow Set the mode control at HI FAN or HI COOL with freezing up and stops the air conditioner the temp at 1 or 2 from cooling the room 14 Customer Service Troubleshooting Tips Operating Instructions Safety Instructions Installation Instruc...

Page 15: ...15 Notes Customer Service Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions ...

Page 16: ...Safety Instructions Installation Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions Notes ...

Page 17: ...otection or you may request your money back on the remaining value of your contract No questions asked It s that simple Protect your refrigerator dishwasher washer and dryer range TV VCR and much more any brand Plus there s no extra charge for emergency service and low monthly financing is available Even icemaker coverage and food spoilage protection is offered You can rest easy knowing that all y...

Page 18: ... ensure that your product is registered or register online at www geappliances com 1 2 3 Model Number Serial Number Cut here Complete and mail your Consumer Product Ownership Registration today Have the peace of mind of knowing we can contact you in the unlikely event of a safety modification After mailing the registration below store this document in a safe place It contains information you will ...

Page 19: ...ler or installer You are responsible for providing adequate electrical connecting facilities Failure of the product resulting from modifications to the product or due to unreasonable use including failure to provide reasonable and necessary maintenance In commercial locations labor necessary to move the unit to a location where it is accessible for service by an individual technician Replacement o...

Page 20: ...l discount GE Consumer Service will still be there after your warranty expires Parts and Accessories 800 626 2002 Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discover cards are accepted Instructions contained in this manual cover procedures to be performed by any user Other servicing generally should be referr...

Reviews: