GE 0150-0241 ProBridge User Manual Download Page 18

Philips ProBridge                        18                                         0150-0241B 

7 Warranty Information 

7.1 Factory Service 

If the unit requires factory service, contact the dealer who supplied the unit to you for the 
correct procedures on returning the unit to the factory or the nearest factory service center. 
If the dealer is not available, contact the manufacturer of the unit as detailed below and 
request a Return Material Authorization number (RMA).  The unit’s serial number must be 
provided before an RMA number can be issued.  Units returned to the factory for service 
must have freight and insurance prepaid, and must show the RMA number clearly on all 
shipping documents.  The failure symptoms must be clearly described by the operator and 
enclosed with the unit together with a copy of the original supplier’s invoice.  Failure to 
comply with these instructions will delay service of the unit, and may result in the unit not 
being accepted by the Repair Center.

 

7.2 Factory Address 

GE Security  

Attention:  Repair Center 

3050 Red Hill Ave. 

Costa Mesa, CA 92626 

United States of America 

Telephone:  800-343-3358  (7:00 AM to 4:30 PM, Pacific Time) 

In Oregon:  541-754-9133 

Fax:  541-754-7162  (24 hours a day) 

 

For warranty information, see the following page. 

7.3 Warranty 

GE Security warrants all of its equipment for three years from the date of purchase. This 
warranty covers any defects in materials and workmanship. Equipment failures that are due 
to improper installation, modification, abuse, or acts of nature will not be covered by this 
warranty. The repair department will evaluate all equipment returned for repair to determine 
warranty coverage. The Tech Support Manager will resolve any questions that may arise 
during evaluation to make a final determination. 

The warranty specifically covers any defects in material and workmanship and does not 
cover equipment that has been abused, damaged, or modified. 

For all warranty repairs

, GE Security will cover all costs, including parts, labor, and 

shipping. Repaired equipment will be returned via the same method of shipment in which it 
was received. If a customer requests a faster return shipment, the difference will be 
charged. 

For all non-warranty repairs

, the customer will be billed for parts, labor, and shipping. 

Labor will be billed in half-hour increments. 

Summary of Contents for 0150-0241 ProBridge

Page 1: ...User Manual 0150 0241 Phillips ProBridge ...

Page 2: ...s of this document For the latest product specifications visit GE Security online at www GE Security com or contact your sales representative For technical support before and after installation call 800 469 1676 Technical support is available 24 hours a day 7 days a week Call Tech Support 800 469 1676 6 A M 5 P M PST Monday through Friday Tech Support 541 740 3589 all other times Main 800 343 3358...

Page 3: ... 6 1 6 Connection Diagrams 7 2 Cable Specifications 8 3 Troubleshooting 9 4 Unit Settings 10 4 1 Configuring ProBridge Jumpers 10 5 Specifications 12 6 Appendix 13 6 1 RS 485 Addressing and Connections 13 6 2 Philip AutoDome Addressing 14 6 3 Using Kalatel Keypads 15 6 4 AUX Operations 16 6 5 Preset Operations 16 7 Warranty Information 18 7 1 Factory Service 18 7 2 Factory Address 18 7 3 Warranty ...

Page 4: ... 1 P N 4010 0008 12VDC 220VAC Power Supply 1 P N 0150 0241A Product Overview and Installation Manual Philips Components 1 Philips Data Converter Unit LTC 8780 1 Philips AutoDome 1 2 Compatibility The CBR PB2 PHILIPS is compatible with all Kalatel DVMRe digital video multiplex recorders equipped with RS 485 network capabilities except installations with a CBR KB1 Keypad Compatible units include the...

Page 5: ...dge is furnished with a power supply 110 or 240 VAC Do not use any other power supply with this product The manufacturer accepts no responsibility for damage caused by the use of any other power supply Make sure installation is complete and all connections are made before applying power to the unit 4310 0007 120VAC Power Supply Power Supply Input Voltage 120 Volt AC Tolerance 10 Frequency 60 Hz Po...

Page 6: ...odems is 3 000 feet 1 000 meters A 100 ohm terminator is required at each end of the RS 485 line 2 Connect the CBR KB3 or KTD 405 keypad to the Kalatel unit DVMRe Simplex DVMRe Triplex DVMRe Matrix via RS 485 port using the RJ45 to RJ45 cable 3 Supply power to the Kalatel unit first and the CBR PB2 PHILIPS second using the supplied AC to 12 VDC adapter Via the Setup Menus for the Kalatel unit set ...

Page 7: ...thernet via WaveReader software and a CBR KB3 or KTD 405 keypad DVMRe Triplex 4310 0034B Cable 4310 0034B Cable 4310 0047B Cable RJ45 RJ45 RJ45 RJ45 RJ45 DB9 F LTC 8780 Data Converter Unit Philips ProBridge KB3 KTD 405 Philips AutoDome MUX DVMR RCVR DVR 9 2 5 1 3 2 9 5 2 1 1 1 7 10 2 6 14 3 0 6 2 2 2 1 8 1 1 2 7 1 5 3 1 7 2 3 3 1 9 12 2 8 16 3 2 8 2 4 4 2 0 AL T F B C D E AUX 2 A U X 1 A U X 3 A U...

Page 8: ...e White Pin 8 Brown Pin 7 Brown White Pin 6 Green Pin 5 Blue White Pin 4 Blue Pin 3 Green White Pin 2 Orange Pin 1 Orange White Do Not Connect Do Not Connect RJ45 RJ45 Connector Connector RJ45 Connector RJ45 Connector ProBridge to Philips Data Converter Unit Part Number 4310 0047B Communication Type RS232 Connector Type RJ 45 DB9F Cable Required 6 Foot RJ 45 to DB9F RS232 Cable Supplied Connects P...

Page 9: ...trol of the PTZ camera please do the following 1 Check that each device is properly powered 2 Check that all cables and cable connections are correct 3 Verify that the Dome addresses and Unit ID are correct 4 If the interface still does not work correctly contact Technical Support ...

Page 10: ...oBridge unit face down Using a small Phillips screwdriver carefully remove the screws located near each corner of the unit Once the screws have been removed lift the cover to detach Identifying The Jumpers With the cover removed orient the unit as shown here There are two sets of configurable jumpers One set located on the left side of the board controls how the unit communicates JP2 JP3 JP4 and J...

Page 11: ...tion JP3 RS485 Position JP4 RS485 Position JP5 RS232 Position P6 Pin 1 Not Installed P6 Pin 2 Not Installed P6 Pin 3 Installed P6 Pin 4 Not Installed P6 Pin 5 Not Installed P6 Pin 6 Not Installed P6 Pin 7 Not Installed P6 Pin 8 Not Installed P6 Pin 9 Not Installed P6 Pin 10 Not Installed P6 Pin 11 Not Installed P6 Pin 12 Not Installed ...

Page 12: ...Color Light gray Environmental Temperature 0 to 40 C operating Relative Humidity 90 non condensing Electrical AC Power External AC power supply included Voltage Range 110 to 240 VAC 10 Current 200 mA DC Power DC jack positive center Power Supply Voltage 12 VDC Current 110 mA Power 1 3 W All specifications are subject to change without notice Kalatel believes that all specifications are correct how...

Page 13: ...in conjunction with multiple Kalatel units and or keypads controlling the domes and the Kalatel units Since the ProBridge unit is a terminated device care should be used when using this unit in a mixed application The RS 485 network is a multi drop wiring configuration of maximum length 3 000 feet 1000 meters RJ45 cable and RJ45 connectors are used for most hookups see the installation connection ...

Page 14: ...ra Mapping RS485 Network Address Camera Address AutoDome Address 001 1 32 0001 0032 002 1 32 0033 0064 003 1 32 0065 0096 004 1 32 0097 0128 005 1 32 0129 0160 006 1 32 0161 0192 007 1 32 0193 0224 008 1 32 0225 0256 009 1 32 0257 0288 010 1 32 0289 0320 011 1 32 0321 0352 012 1 32 0253 0384 013 1 32 0385 0416 014 1 32 0417 0448 015 1 32 0449 0480 016 1 32 0481 0512 017 1 32 0513 0544 018 1 32 054...

Page 15: ...4 set to OFF Switch 2 set to ON S102 Switches 1 3 set on ON switch 4 set to OFF See Philips LTC8780 manual for details 6 3 Using Kalatel Keypads Keyboards CBR KB3 J and KTD 405 are typically used to provide initial configuration of the Philips AutoDome for setting addresses and presets In some specific cases keyboards may be used in conjunction with the CBR PB2 PHILIPS units where multiple Kalatel...

Page 16: ...es as follows Remote Keypad Fuction Aux1 On Off Scan Aux2 On Off Auto Pan Aux3 On Off Continuous Playback A Start Stop Aux4 On Off Continuous Playback B Start Stop Aux5 On Off Record Sequence A Aux6 On Off Record Sequence B Aux7 Momentary Preset Tour Start Move Joystick to stop Aux8 Momentary Start Advanced Menu Mode 6 5 Preset Operations The Philips AutoDome can store up to 99 preset operations 1...

Page 17: ... Preshot Number Select the camera key to the desired preset number The Dome will go to that existed Preset position and clear this preset 2 Move the Dome to the new position by using the joystick or arrow keys 3 Repeat step 1 Press Preset key twice The KB3 LCD will display Set Preshot Number Select the camera key to the preset number Now the new preset position is stored 4 Verify by calling up tha...

Page 18: ...tes of America Telephone 800 343 3358 7 00 AM to 4 30 PM Pacific Time In Oregon 541 754 9133 Fax 541 754 7162 24 hours a day For warranty information see the following page 7 3 Warranty GE Security warrants all of its equipment for three years from the date of purchase This warranty covers any defects in materials and workmanship Equipment failures that are due to improper installation modificatio...

Page 19: ...ck and receive the returned product in exchange The received equipment will be evaluated and the repair department will determine whether it is a warranty replacement If it is non warranty see our repair policy above for details The following guidelines will be used for all advance replacements Fewer than 45 days from purchase GE Security will replace the product with new equipment From 45 days to...

Reviews: