GE Security SuperBus 2000 Installation Instructions Download Page 3

3

SuperBus 2000 900MHZ RF Transceiver Module Installation Instructions

Preliminary 3/1/04

¾

To mount the module on a wall:

1. Remove the panel AC power transformer and disconnect the backup battery.
2. Remove the module cover and set it aside.
3. Hold the base against the mounting surface and mark the three mounting holes. Remember to 

leave at least 10 inches

 

above the base for the antenna.

4. Drill holes and insert the appropriate anchors.
5. Secure the back-plate to the wall with included panhead screws.

Concord Panel Wiring

This section describes how to wire the transceiver module to Concord panels.

¾

To wire the transceiver module to Concord panels:

1. Disconnect the panel power transformer and backup battery.
2. Wire the module to the panel power and bus terminals as shown in Figure 3.

Figure 3. Wiring Module to Concord Panel

Power Up

Use the following procedures for powering up the system and verifying bus communication.

Note 

In order to enter panel pro-
gram mode to verify unit 
numbers, an alphanumeric 
touchpad must be con-
nected to all Concord pan-
els.

¾

To power up the panel and transceiver module:

1. Verify that all wiring at the panel, touchpad, and transceiver is correct.
2. Connect the panel backup battery and plug in the panel AC power transformer.
3. Verify that the transceiver module status LED is on.
4. If desired, enter panel program mode to verify unit number exists (see panel 

Installation 

Instructions 

for more information).

Note  

If the transceiver module LED is not on, unplug the panel AC power transformer, disconnect the backup 
battery, and see Table 3 “Troubleshooting”.

Specifications

Compatibility: ............................GE Security Concord panels. GE Security 900 MHz wireless sensors and 

touchpads

Power Required: ........................12 VDC nominal 500 mA maximum draw (from panel)
Storage Temperature:.................-30° to 140°F (-34° to 60°C)
Operating Temperature: ............. 32° to 140°F (0° to 60°C)
Maximum Humidity: .................90% relative humidity, noncondensing
Wireless Signal Range:.............. 1,500 feet nominal, 2,000 feet typical open air (may vary with application)
Dimensions:  .............................. 4.125” x 5.25” x 1.0” (L x W x H), excluding antenna

To prevent damaging the panel or module, remove the panel AC power transformer 
and disconnect the backup battery before installation.

Caution

!

You must be free of static electricity before handling circuit boards. Wear a ground-
ing strap or touch a bare metal surface to discharge static electricity.

Static

6

3

4

5

PANEL 

TERMINAL STRIP

+12

VDC

BUS

A

BUS

B

GND

SUPERBUS 2000

RF  TRANSCEIVER MODULE

 

TERMINAL STRIP

4

1

2

3

+12

VDC

BUS

A

BUS

B

GND