Table 1: Loop Resistance per 1000 feet 

Wire Type 

Resistance 

24 AWG /0,53 mm 

52 ohms 

23 AWG /0,57 mm 

42 ohms 

22 AWG /0,64 mm 

33 ohms 

 

Table 2: Power Distance Chart 

Power Supply Voltage 

12 VDC 

24 VAC 

28 VAC 

Voltage at the Camera 

10.8 VDC 

21.6 VAC 

21.6 VAC 

Dual 24 AWG 

448 ft. / 137 m 

896 ft. / 273 m 

2,388 ft. / 728 m 

100 mA Camera 

Dual 23 AWG 

564 ft. / 172 m  1,130 ft. / 345 m 

3,012 ft. / 918 m 

Dual 24 AWG 

150 ft. / 46

 

m 300 

ft. 

92

 

796 ft. / 243 m 

300 mA Camera 

Dual 23 AWG 

190 ft. / 58 m 

378 ft. / 115 m 

1,004 ft. / 306 m 

Dual 24 AWG 

46 ft. / 14 m 

90 ft. / 28 m 

240 ft. / 73 m 

1 AMP Camera 

Dual 23 AWG 

58 ft. / 18 m 

114 ft. / 35 m 

300 ft. / 92 m 

 

Application Drawings 

Multi-channel Passive to Active (Mid-Range) Application 

 

Summary of Contents for GEC-16VARHUB-4

Page 1: ...any GE Passive Transceiver for distances up to 3 500 feet 1 067 m The 8 channel models provide 1 to 4 distribution amplifiers while the 16 channel models include 1 to 2 distribution amplifiers These receiver hubs are 1U in height and can be wall desk or rack mounted Their integrated ground loop isolation prevents disturbing hum bars common with long distance installations Their excellent crosstalk...

Page 2: ...ing No objects filled with liquids such as vases shall be placed on GE equipment DO NOT block ventilation openings to let sufficient airflow to the UTP devices The Main fuse for models with built in AC power supply is 5 A at 110 VAC or at 3 A 220 VAC Each camera power fuse is 2 A and can be accessed by removing the front panel Fuses may be replaced by a qualified service person only when the unit ...

Page 3: ...as been damaged in any way such as a power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture This apparatus shall not be exposed to dripping or splashing ...

Page 4: ...ivers Passive GE transceivers can transmit video and Up the Coax P T Z control signals up to 750 ft 228 m We recommend using short 18 AWG solid wires for ground connections GE VPD products follow the EIA TIA 568 standard There are two wire color code standards EIA TIA 568A and EIA TIA 568B Either standard can be used for making connections as long as the RJ 45 jacks at both ends of each cable foll...

Page 5: ...e Camera 10 8 VDC 21 6 VAC 21 6 VAC Dual 24 AWG 448 ft 137 m 896 ft 273 m 2 388 ft 728 m 100 mA Camera Dual 23 AWG 564 ft 172 m 1 130 ft 345 m 3 012 ft 918 m Dual 24 AWG 150 ft 46 m 300 ft 92 m 796 ft 243 m 300 mA Camera Dual 23 AWG 190 ft 58 m 378 ft 115 m 1 004 ft 306 m Dual 24 AWG 46 ft 14 m 90 ft 28 m 240 ft 73 m 1 AMP Camera Dual 23 AWG 58 ft 18 m 114 ft 35 m 300 ft 92 m Application Drawings ...

Page 6: ...e GEC PVTC FCSP GEC PVTC MSP Connect the UTP to the terminal block of the GE transceiver Active Transmitter Connect the baseband video output of the camera to the BNC input of the GE active transmitter Connect the UTP to the terminal block of transmitter Connect the ground screw connector to a qualified earth ground using a short thick wire Set the distance switch to the appropriate position based...

Page 7: ...o inputs of video receiving devices such as DVRs or matrix switches Power GEC 4VARHUB 4 Connect the ground screw connector to a qualified earth ground using a short thick wire Connect the external power supply cable to the power input connector of the GEC 4VARHUB 4 Note This product is intended to be supplied by a UL Listed Direct Plug In Power Unit marked Class 2 or LPS and output rated 12 VDC 1 ...

Page 8: ...nt Green LED s one per channel Power indicator Red LED Connectors UTP inputs Detachable terminal blocks RJ 45 or Optional RJ 45 Adapter Included Video Outputs BNC Power IEC380 AC power inlet excluding GEC 4VARHUB 4 Standard P1J DC inlet receptacle 2 1 x 5 5 mm center positive GEC 4VARHUB 4 Main AC Fuse 1 A at 115 VAC 3 A at 220 VAC 5x20 mm 8 channel models 1 5 A at 115 VAC 5 A at 220 VAC 5x20 mm 1...

Page 9: ...ct Plug In Power Unit marked Class 2 or LPS and output rated 12 VDC 1 Amp minimum Mechanical Material GEC 4VARHUB 4 ABS plastic UL rating of 94V 0 All other models Extruded Aluminum and sheet metal Dimensions W x H x D GEC 4VARHUB 4 4 97 x 1 74 x 1 77 in 12 6 x 4 2 x 4 5 cm GEC 8VARHUB 4 17 x 1 74 x 8 in 43 x 4 2 x 203 cm GEC 16VARHUB 4 17 x 1 74 x 8 in 43 x 4 2 x 203 cm GEC 32VARHUB 4 17 x 1 74 x...

Page 10: ... Accessories Excluding the GEC 4VARHUB 4 Mounting brackets for front rear or wall installations Rubber feet for desk applications 8 16 or 32 2 ft 60 cm coax jumper cables RJ 45 Adapter Molded IEC power inlet cord 7 ft 200 cm EIA TIA 568A B Color Codes ...

Page 11: ... there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation betwee...

Reviews: