GE Multilin
L60 Line Phase Comparison System
B-71
APPENDIX B
B.4 MEMORY MAPPING
B
D368
...Repeated for Remote Device 3
D36C
...Repeated for Remote Device 4
D370
...Repeated for Remote Device 5
D374
...Repeated for Remote Device 6
D378
...Repeated for Remote Device 7
D37C
...Repeated for Remote Device 8
D380
...Repeated for Remote Device 9
D384
...Repeated for Remote Device 10
D388
...Repeated for Remote Device 11
D38C
...Repeated for Remote Device 12
D390
...Repeated for Remote Device 13
D394
...Repeated for Remote Device 14
D398
...Repeated for Remote Device 15
D39C
...Repeated for Remote Device 16
D3A0
...Repeated for Remote Device 17
D3A4
...Repeated for Remote Device 18
D3A8
...Repeated for Remote Device 19
D3AC
...Repeated for Remote Device 20
D3B0
...Repeated for Remote Device 21
D3B4
...Repeated for Remote Device 22
D3B8
...Repeated for Remote Device 23
D3BC
...Repeated for Remote Device 24
D3C0
...Repeated for Remote Device 25
D3C4
...Repeated for Remote Device 26
D3C8
...Repeated for Remote Device 27
D3CC
...Repeated for Remote Device 28
D3D0
...Repeated for Remote Device 29
D3D4
...Repeated for Remote Device 30
D3D8
...Repeated for Remote Device 31
D3DC
...Repeated for Remote Device 32
Contact Outputs (Read/Write Setting) (64 Modules)
D3E0
Contact Output 1 Name
---
---
---
F205
“Cont Op 1"
D3E6
Contact Output 1 Operation
0 to 4294967295
---
1
F300
0
D3E8
Contact Output 1 Seal In
0 to 4294967295
---
1
F300
0
D3EA
Latching Output 1 Reset
0 to 4294967295
---
1
F300
0
D3EC
Contact Output 1 Events
0 to 1
---
1
F102
1 (Enabled)
D3ED
Latching Output 1 Type
0 to 1
---
1
F090
0 (Operate-
dominant)
D3EE
Reserved
---
---
---
F001
0
D3EF
...Repeated for Contact Output 2
D3FE
...Repeated for Contact Output 3
D40D
...Repeated for Contact Output 4
D41C
...Repeated for Contact Output 5
D42B
...Repeated for Contact Output 6
D43A
...Repeated for Contact Output 7
D449
...Repeated for Contact Output 8
D458
...Repeated for Contact Output 9
D467
...Repeated for Contact Output 10
D476
...Repeated for Contact Output 11
D485
...Repeated for Contact Output 12
D494
...Repeated for Contact Output 13
D4A3
...Repeated for Contact Output 14
D4B2
...Repeated for Contact Output 15
D4C1
...Repeated for Contact Output 16
Table B–10: MODBUS MEMORY MAP (Sheet 63 of 65)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Summary of Contents for L60
Page 10: ...x L60 Line Phase Comparison System GE Multilin TABLE OF CONTENTS ...
Page 57: ...GE Multilin L60 Line Phase Comparison System 2 27 2 PRODUCT DESCRIPTION 2 3 SPECIFICATIONS 2 ...
Page 58: ...2 28 L60 Line Phase Comparison System GE Multilin 2 3 SPECIFICATIONS 2 PRODUCT DESCRIPTION 2 ...
Page 482: ...6 26 L60 Line Phase Comparison System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Page 554: ...10 8 L60 Line Phase Comparison System GE Multilin 10 2 BATTERIES 10 MAINTENANCE 10 ...
Page 674: ...B 110 L60 Line Phase Comparison System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Page 704: ...C 30 L60 Line Phase Comparison System GE Multilin C 7 LOGICAL NODES APPENDIX C C ...
Page 720: ...E 10 L60 Line Phase Comparison System GE Multilin E 1 PROTOCOL APPENDIX E E ...
Page 732: ...F 12 L60 Line Phase Comparison System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Page 742: ...H 8 L60 Line Phase Comparison System GE Multilin H 3 WARRANTY APPENDIX H H ...